Chbeb High Voltage Load Break Disconnector with Customer Requirements

Product Details
Customization: Available
Type: 10kv/12kv/15kv
Structure: According to Customer Requirements
Still deciding? Get samples of $ !
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW PayPal
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

OEM Services
The supplier provides OEM services for popular brands
Quality Assurance
The supplier provides quality assurance
Private Mold
The supplier has private mold
Product Certification
The supplier's products already have relevant certification qualifications, including:
CE
to see all verified strength labels (20)
  • Chbeb High Voltage Load Break Disconnector with Customer Requirements
  • Chbeb High Voltage Load Break Disconnector with Customer Requirements
  • Chbeb High Voltage Load Break Disconnector with Customer Requirements
  • Chbeb High Voltage Load Break Disconnector with Customer Requirements
  • Chbeb High Voltage Load Break Disconnector with Customer Requirements
  • Chbeb High Voltage Load Break Disconnector with Customer Requirements
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Certifications
Overview

Basic Info.

Model NO.
(H)GWBEB
Installation
Outdoor High-voltage
Operation
Manual/Electric/Pneumatic/Hydraulic
Grounding Mode
According to Customer Requirements
Movement Mode
According to Customer Requirements
Number of Poles
According to Customer Requirements
Grounding
According to Customer Requirements
Series
Two
Run
According to Customer Requirements
Switching Mode
According to Customer Requirements
Common Model
Gw9
Structure of Operating
According to Customer Requirements
Certification
ISO, RoHS, CE
Brand
Chbeb
Customizable
OEM/According to Customer Requirements
Transport Package
Standard Shipping Packing
Specification
45*55*38mm
Trademark
CHBEB
Origin
China
HS Code
853530900
Production Capacity
5000 PCS/Quarter

Product Description

Chbeb High Voltage Load Break Disconnector with Customer Requirements
Product Description

(H)GWBEB type outdoor high-voltage isolation switch, often referred to as an isolation disconnect switch, is masterfully crafted for seamless operation on 10(12, 15, 24)kV high voltage power transmission and distribution lines. This switch excels in opening and closing single-phase or three-phase circuits, all while maintaining voltage presence. Offering unmatched reliability and efficiency, it stands as a pivotal component in high voltage systems.

The switch is purpose-built for single-phase applications within three-phase line systems, renowned for its uncomplicated design, cost-effectiveness, and user-friendly operation. It boasts a range of rated currents, including 200, 400, 600, 800, 1000, and 1250 amps, catering to diverse needs. Each intricately designed switch is composed of a robust base, durable post insulators, conductive elements, and a precision-engineered mechanical section. The innovative gate knife mechanism ensures precise circuit operations, with each phase's knife comprising dual conductive blades, enhanced by external compression springs on either side. Adjusting the spring height fine-tunes the essential contact pressure for flawless switch performance. Operational simplicity is achieved through an insulated hook stick, complemented by a reliable self-locking device for secure actions.

Working Environment:

Altitude threshold: not exceeding 1000 meters;

Ambient temperature: peak not above +40°C; base not below -30°C;

Outdoor wind speed: capped at 35 meters/second;

Seismic intensity limit: not exceeding 8 degrees; installation sites should be free from frequent severe vibrations.

Installation sites must be devoid of gases, chemical residues, salt mist, dust, dirt, or other explosive or corrosive elements that could significantly impact the switch's insulation and conductivity.

Note:

WHEN THE NORMAL CONDITIONS OF USE ARE EXCEEDED, USERS HAVE THE OPTION TO DISCUSS ALTERNATIVE ARRANGEMENTS WITH OUR COMPANY.

Installation, Use and Adjustment

Pre-installation work

  1. Thoroughly remove dust and dirt from all components, ensuring that the insulating porcelain bottle’s surface is meticulously cleaned.
  2. Carefully scrub the wiring surface associated with the ground screw to ensure optimal connectivity.
  3. Apply a protective layer of industrial Vaseline to rotating parts and contact areas to enhance longevity and performance.
  4. Inspect the contact surfaces, adjusting the compression spring height to guarantee that the contact pressure aligns with the specifications outlined in Table II.
  5. This switch is exclusively designed for hoisting use and is meant to operate in tandem with transformers on the line, ensuring reliability and functionality.
  6. The switch’s rated current capacity ranges from 200 to 400 ampere hours. For optimal setup, generally three mounting holes are utilized, while 600-1000A configurations also employ three mounting holes.

Conduct an annual inspection on the following switch components:
Diligently clean dirt from conductive parts, contact surfaces, and the insulating porcelain bottles' surfaces for sustained performance.

Thoroughly check all components for damage, with particular attention to the insulating porcelain bottle for any signs of damage or cracks.

Examine the contact surfaces of conductive parts to ensure they are in optimal condition for effective operation.


Chbeb High Voltage Load Break Disconnector with Customer Requirements

Detailed Photos

Chbeb High Voltage Load Break Disconnector with Customer Requirements
Chbeb High Voltage Load Break Disconnector with Customer Requirements
Chbeb High Voltage Load Break Disconnector with Customer Requirements
Chbeb High Voltage Load Break Disconnector with Customer Requirements


Chbeb High Voltage Load Break Disconnector with Customer Requirements
Chbeb High Voltage Load Break Disconnector with Customer Requirements

Chbeb High Voltage Load Break Disconnector with Customer Requirements
Chbeb High Voltage Load Break Disconnector with Customer Requirements
Chbeb High Voltage Load Break Disconnector with Customer Requirements
Chbeb High Voltage Load Break Disconnector with Customer Requirements
Chbeb High Voltage Load Break Disconnector with Customer Requirements
Chbeb High Voltage Load Break Disconnector with Customer Requirements
Chbeb High Voltage Load Break Disconnector with Customer Requirements
Chbeb High Voltage Load Break Disconnector with Customer Requirements
Chbeb High Voltage Load Break Disconnector with Customer Requirements
Chbeb High Voltage Load Break Disconnector with Customer Requirements
Chbeb High Voltage Load Break Disconnector with Customer Requirements
Chbeb High Voltage Load Break Disconnector with Customer Requirements

Product Parameters

The main technical parameters

Table I

Model

Rated voltage
kV

 

Rated current
A

kA

 

10 seconds thermal stable current
kA

peak

Valid values

 

(H)GW

 

10

12

15

200

5

9

5

400

21

15

10

600

35

25

14

630

35

25

14

800

35

25

14

1000

50

35

20

Contact force parameters

Table II

Model

Rated current(A)

contact pressure(kgf)

(H)GW

5

9

21

15

35

25

35

25

35

25

50

35

Certifications

Chbeb High Voltage Load Break Disconnector with Customer RequirementsChbeb High Voltage Load Break Disconnector with Customer Requirements

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier