Outdoor High Voltage Load Break Disconnect Isolator Switch 45*55*38mm

Product Details
Customization: Available
Type: 10kv/12kv/15kv
Structure: According to Customer Requirements
Still deciding? Get samples of $ !
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

OEM Services
The supplier provides OEM services for popular brands
Quality Assurance
The supplier provides quality assurance
Private Mold
The supplier has private mold
Product Certification
The supplier's products already have relevant certification qualifications, including:
CE
to see all verified strength labels (20)
  • Outdoor High Voltage Load Break Disconnect Isolator Switch 45*55*38mm
  • Outdoor High Voltage Load Break Disconnect Isolator Switch 45*55*38mm
  • Outdoor High Voltage Load Break Disconnect Isolator Switch 45*55*38mm
  • Outdoor High Voltage Load Break Disconnect Isolator Switch 45*55*38mm
  • Outdoor High Voltage Load Break Disconnect Isolator Switch 45*55*38mm
  • Outdoor High Voltage Load Break Disconnect Isolator Switch 45*55*38mm
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Certifications
Overview

Basic Info.

Model NO.
(H)GWBEB
Installation
Outdoor High-voltage
Operation
Manual/Electric/Pneumatic/Hydraulic
Grounding Mode
According to Customer Requirements
Movement Mode
According to Customer Requirements
Number of Poles
According to Customer Requirements
Grounding
According to Customer Requirements
Series
Two
Run
According to Customer Requirements
Switching Mode
According to Customer Requirements
Common Model
Gw9
Structure of Operating
According to Customer Requirements
Certification
ISO, RoHS, CE
Brand
Chbeb
Customizable
OEM/According to Customer Requirements
Transport Package
Standard Shipping Packing
Specification
45*55*38mm
Trademark
CHBEB
Origin
China
HS Code
853530900
Production Capacity
5000 PCS/Quarter

Product Description

Outdoor High Voltage Load Break Disconnect Isolator Switch 45*55*38mm
Product Description

Introducing the (H)GWBEB type outdoor high-voltage isolation switch—an essential component, also referred to as an isolation disconnect switch. This innovative switch is expertly crafted for 10(12, 15, 24)kV high voltage power transmission and distribution lines. It is devised to efficiently manage the opening and closing of single-phase or three-phase circuits, even when voltage is present but without any load. A perfect blend of functionality and reliability!

Designed specifically for single-phase use in three-phase line systems, this switch is renowned for its straightforward structure, cost-effectiveness, and user-friendly operation. It is available in a range of rated currents, including 200, 400, 600, 800, 1000, and 1250 amps. The switch is intricately assembled from a base, post insulators, conductive components, and a mechanical sector. It employs a gate knife structure for seamless circuit operations. Each phase includes a gate knife with two conductive blades, enhanced by external compression springs on both sides. The spring height can be finely tuned to provide optimal contact pressure. For ease of operation, the switch employs an insulated hook stick for efficient opening and closing actions, and it incorporates a secure self-locking mechanism.

Working Environment:

Operate smoothly at altitudes not exceeding 1000 meters;

Thrives in ambient temperatures with a maximum not above +40°C and a minimum not below -30°C;

Built to withstand outdoor wind speeds not exceeding 35 meters/second;

Engineered to endure seismic intensities not exceeding 8 degrees, ensuring the installation site remains free from frequent severe vibrations.

The installation environment should be free of gases, chemical deposits, salt mist, dust, dirt, or other explosive or corrosive mediums that could significantly impact the switch's insulation and conductivity. A flawless performance guaranteed!

Note:

WHEN THE ABOVE NORMAL USE CONDITIONS ARE EXCEEDED, USERS CAN ENGAGE IN NEGOTIATIONS WITH THE COMPANY FOR CUSTOMIZED SOLUTIONS.

Installation, Use, and Adjustment

Pre-installation work

  1. Ensure all components are clean by removing dust and dirt. Carefully wipe the insulating porcelain bottle's surface for a pristine start.
  2. Thoroughly scrub the wiring surface of the ground screw to ensure a secure connection.
  3. Protect and maintain rotating parts and contact areas by applying a layer of industrial Vaseline.
  4. Meticulously check the contact surface and adjust the compression spring's height so that the contact pressure aligns perfectly with Table II.
  5. Please note: This switch is designed exclusively for hoisting use and is to be used in conjunction with the transformer on the line, ensuring seamless integration and efficiency.
  6. This switch, with a rated current ranging from 200-400 ampere hours, generally requires only three mounting holes for optimal installation. For currents of 600-1000A, three mounting holes are used to ensure stability.

Conduct an annual check of the following switch components for optimal performance:
Ensure all conductive parts, contact surfaces, and the insulating porcelain bottles are free from dirt for immaculate performance.

Inspect all parts for potential damage, especially the insulating porcelain bottle, checking for any signs of cracks or damage.

Verify the integrity and condition of the conductive part's contact surface for efficient operation.


Outdoor High Voltage Load Break Disconnect Isolator Switch 45*55*38mm

Detailed Photos

Outdoor High Voltage Load Break Disconnect Isolator Switch 45*55*38mm
Outdoor High Voltage Load Break Disconnect Isolator Switch 45*55*38mm
Outdoor High Voltage Load Break Disconnect Isolator Switch 45*55*38mm
Outdoor High Voltage Load Break Disconnect Isolator Switch 45*55*38mm


Outdoor High Voltage Load Break Disconnect Isolator Switch 45*55*38mm
Outdoor High Voltage Load Break Disconnect Isolator Switch 45*55*38mm

Outdoor High Voltage Load Break Disconnect Isolator Switch 45*55*38mm
Outdoor High Voltage Load Break Disconnect Isolator Switch 45*55*38mm
Outdoor High Voltage Load Break Disconnect Isolator Switch 45*55*38mm
Outdoor High Voltage Load Break Disconnect Isolator Switch 45*55*38mm
Outdoor High Voltage Load Break Disconnect Isolator Switch 45*55*38mm
Outdoor High Voltage Load Break Disconnect Isolator Switch 45*55*38mm
Outdoor High Voltage Load Break Disconnect Isolator Switch 45*55*38mm
Outdoor High Voltage Load Break Disconnect Isolator Switch 45*55*38mm
Outdoor High Voltage Load Break Disconnect Isolator Switch 45*55*38mm
Outdoor High Voltage Load Break Disconnect Isolator Switch 45*55*38mm
Outdoor High Voltage Load Break Disconnect Isolator Switch 45*55*38mm
Outdoor High Voltage Load Break Disconnect Isolator Switch 45*55*38mm

Product Parameters

The main technical parameters

Table I

Model

Rated voltage
kV

 

Rated current
A

kA

 

10 seconds thermal stable current
kA

peak

Valid values

 

(H)GW

 

10

12

15

200

5

9

5

400

21

15

10

600

35

25

14

630

35

25

14

800

35

25

14

1000

50

35

20

Contact force parameters

Table II

Model

Rated current(A)

contact pressure(kgf)

(H)GW

5

9

21

15

35

25

35

25

35

25

50

35

Certifications

Outdoor High Voltage Load Break Disconnect Isolator Switch 45*55*38mmOutdoor High Voltage Load Break Disconnect Isolator Switch 45*55*38mm

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now