High-Performance Customizable Surge Arrester for Voltage Protection Solutions

Product Details
Customization: Available
Type: Power Source Arrester
Structure: Zinc Oxide Arrester
Still deciding? Get samples of US$ 35/Piece
Request Sample
Manufacturer/Factory

360° Virtual Tour

Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

OEM Services
The supplier provides OEM services for popular brands
Quality Assurance
The supplier provides quality assurance
Private Mold
The supplier has private mold
Product Certification
The supplier's products already have relevant certification qualifications, including:
CE
to see all verified strength labels (19)
  • High-Performance Customizable Surge Arrester for Voltage Protection Solutions
  • High-Performance Customizable Surge Arrester for Voltage Protection Solutions
  • High-Performance Customizable Surge Arrester for Voltage Protection Solutions
  • High-Performance Customizable Surge Arrester for Voltage Protection Solutions
  • High-Performance Customizable Surge Arrester for Voltage Protection Solutions
  • High-Performance Customizable Surge Arrester for Voltage Protection Solutions
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Certifications
  • Company Profile
Overview

Basic Info.

Model NO.
YH series
Installation
According to Customer Requirements
Application
AC/DC System/Power Plants/Substation
Size
According to Customer Requirements
Operation Voltage
3 - 36kv
Shape
According to Customer Requirements
Material
ZnO
Certification
ROHS, ISO9001, CCC
Brand
Chbeb
Customizable
OEM/According to Customer Requirements
Voltage Customizable
30kv 33kv 36kv
Transport Package
Pallet
Trademark
CHBEB
Origin
China
HS Code
8535400000
Production Capacity
50000 Pieces/Quarter

Product Description

Product Description

Introducing the Zinc Oxide Arrester from Beierbian Group Co., Ltd – a state-of-the-art, fully sealed marvel of lightning protection designed specifically for 10kV power distribution systems. This extraordinary device represents the pinnacle of engineering prowess, meticulously crafted with a zinc oxide valve column, enhanced by precision-engineered upper and lower electrodes. The entire assembly is flawlessly enveloped in silicone rubber, delivering extraordinary features and advantages:

  1. This groundbreaking design ingeniously tackles and resolves the historical sealing challenges faced in traditional arresters. By seamlessly merging the core and jacket into a single, streamlined unit, it completely eliminates any potential cavities that might provoke internal breathing complications. This innovative approach brilliantly overcomes technical barriers, effectively preventing moisture ingress into the internal components, thus ensuring long-lasting reliability and performance.
  2. This robust design features a powerful core, boasting an exceptional capacity to withstand internal overvoltage. The arrester is renowned for its superb aging resistance, guaranteeing consistent performance and steadfast protection over the years, cementing its reputation as an industry leader in voltage protection solutions.

Equipped with a specially designed valve plate and optimized core parameters, this arrester ensures that the core can effortlessly handle complex challenges such as arc grounding, PT resonance, and a wide range of operational overvoltages. It operates with absolute reliability under line voltage, and withstands 2.5 to 3 times the power frequency overvoltage. Its voltage withstand duration exceeds international standards by 1 to 3 orders of magnitude, ensuring unmatched safety and a remarkably extended operational life.
High-Performance Customizable Surge Arrester for Voltage Protection Solutions

Detailed Photos

High-Performance Customizable Surge Arrester for Voltage Protection Solutions

High-Performance Customizable Surge Arrester for Voltage Protection Solutions
High-Performance Customizable Surge Arrester for Voltage Protection Solutions
High-Performance Customizable Surge Arrester for Voltage Protection Solutions
High-Performance Customizable Surge Arrester for Voltage Protection Solutions
High-Performance Customizable Surge Arrester for Voltage Protection Solutions
High-Performance Customizable Surge Arrester for Voltage Protection Solutions

Product Parameters

Main Characteristics Of Jacket Materials And Product Usage Environment: Discover the distinct features of our superior jacket materials, expertly engineered to thrive under various environmental conditions.

Item

Unit

Norm

Shore Hardness A

/

60

Tensile Strength

mpa

≥35

Breaking Elongation

%

≥250

Oxygen Index

/

45

Resistivity

Ω.m

≥1×1013

Breakdown Strength

MV/m

≥25

Tracking

kV

4.5

Durability

Not less than 20 years

Working Environment: Tailored for flawless functionality across a spectrum of settings, ensuring reliability and endurance under challenging conditions.

Specifically designed for seamless operation both indoors and outdoors; Experience the versatility and resilience of our arrester, suitable for any setting you choose.

Effective operation at altitudes up to a majestic 3000m; Witness the remarkable performance of our device, sustaining excellent operation even at significant altitudes.

Capable of withstanding ambient temperatures ranging from a chilly -40C to a balmy +60C; Built to endure extreme temperature variations, guaranteeing peak performance in both icy and warm climates.

Compatible with power supply frequencies from a steady 48Hz to a dynamic 62Hz; Adaptable to a range of power frequencies, ensuring smooth and reliable operation across different electrical setups.

Ensures power frequency voltage applied between terminals remains within optimal limits for prolonged use. Offers sustained efficiency, maintaining voltage integrity for long-term reliability.

Can endure seismic activities with intensity not exceeding 8 degrees. Designed with resilience in mind, ensuring steadfast performance even in areas prone to seismic disturbances.

Engineered to resist outdoor wind speeds reaching up to 35 meters/second; Crafted for durability, steadfast against the forces of nature withstanding high wind velocities.

Note: Empower yourself with the flexibility of customized solutions, addressing unique challenges beyond standard parameters.

Should you encounter conditions beyond these normal operational parameters, feel free to discuss tailored solutions with our team. We are committed to providing bespoke solutions to meet your specific needs.

Main technical parameters: Explore the core technological specifications that highlight the superior engineering of our surge arrester.

Model

Nominal Voltage

(rms)

Rated Voltage OArrester

(rms)

Continuous Operating Voltage

(rms)

DC 1mA reference voltage
kV not less than

The residual voltage under nominal discharge current
kV (Crest) not greater than

Steep wave impact residual voltage
kV (Crest) not greater than

2ms square wave flow capacity
A

Operation Place

YH5WS-3.8/17

3

3.8

2.0

7.5

17.0

19.6

100

 

Distribution Type

YH5WS-5/15

3

5

4.0

7.5

15.0

17.3

150

YH5WS-7.6/30

6

7.6

4.0

15.0

15.0

34.5

100

YH5WS-10/30

6

10

8.0

15.0

30.0

34.6

150

YH5WS-12.7/50

10

12.7

10

26.0

50.0

57.5

100

YH5WS-16.5/50

10

16.5

12.7

26.0

50.0

57.5

100

YH5WS-17/50

10

17

13.6

26.0

50.0

57.5

150

YH5WS-17/45

10

17

13.6

25.0

45.0

/

250

YH10WS-17/45

10

17

13.6

25.0

45.0

/

400

YH5WZ-5/13.5

3

5

4.0

7.2

13.5

15.5

200

Power Station Type

YH5WZ-7.6/27

6

7.6

4.0

14.4

27.0

31.0

150

YH5WZ-10/27

6

10

8.0

14.4

27.0

31.0

200

YH5WZ-42/134

35

42

23.4

73

134

154

150

YH5WZ-12.7/45

10

12.7

6.6

24.0

45.0

51.8

150

YH5WZ-16.5/45

10

16.5

13.2

24.0

45.0

51.8

150

YH5WZ-17/45

10

17

13.6

24.0

45.0

51.8

200

YH5WZ-51/134

35

51

40.8

73.0

134

154

400

YH10WZ-17/45

10

17

13.6

24.0

45.0

51.8

200

YH10WZ-51/134

35

51

40.8

73.0

134

154

400

YH5WR-5/13.5

3

5

4.0

7.2

13.5

/

400

Capacitive Type

YH5WR-7.6/27

6

7.6

4.0

13.8

27.0

/

400

YH5WR-10/27

6

10

8.0

14.4

27.0

/

400

YH5WR-12.7/45

10

12.7

6.6

23.0

45.0

/

400

YH5WR 17/45

10

17

13.6

24.0

45.0

/

400

YH5WX-51/134

35

51

40.8

73

134.0

154

400

Line type

YH1.5W-30/80

35

30

24

44

80.0

/

600

Neutral Type

Note: Featuring a robust Polymeric build; Enjoy the benefits of a durable design, ensuring longevity and resilience in various applications.

Model

Nominal Voltage

(rms)

Rated Voltage OArrester

(rms)

Continuous Operating Voltage

(rms)

DC 1mA Reference Voltage
kV Not Less Than

The Residual Voltage Under Nominal Discharge Current
kV (Crest)
Not Greater Than

Steep Wave Impact Residual Voltage
kV (Crest)
Not Greater Than

2ms Square Wave Flow Capacity
A

Operation Place

Y5WS-5/15

3

5

4.0

7.5

15.0

17.3

150

Distribution Type

Y5WS-7.6/30

6

7.6

4.0

15.0

15.0

34.5

100

Y5WS-10/30

6

10

8.0

15.0

30.0

34.6

150

Y5WS-12.7/50

10

12.7

10

26.0

50.0

57.5

100

Y5WS-16.5/50

10

16.5

12.7

26.0

50.0

57.5

100

Y5WS-17/50

10

17

13.6

26.0

50.0

57.5

150

Y5WZ-5/13.5

3

5

4.0

7.2

13.5

15.5

200

Power Station Type

Y5WZ-7.6/27

6

7.6

4.0

14.4

27.0

31.0

150

Y5WZ-10/27

6

10

8.0

14.4

27.0

31.0

200

Y5WZ-42/134

35

42

23.4

73

134

154

150

Y5WZ-12.7/45

10

12.7

6.6

24.0

45.0

51.8

150

Y5WZ-16.5/45

10

16.5

13.2

24.0

45.0

51.8

150

Y5WZ-17/45

10

17

13.6

24.0

45.0

51.8

200

Y5WZ-51/134

35

51

40.8

73.0

134

154

400

Y5WR-5/13.5

3

5

4.0

7.2

13.5

/

400

Capacitive Type

Y5WR-7.6/27

6

7.6

4.0

13.8

27.0

/

400

Y5WR-10/27

6

10

8.0

14.4

27.0

/

400

Y5WR-12.7/45

10

12.7

6.6

23.0

45.0

/

400

Y5WR-17/45

10

17

13.6

24.0

45.0

/

400

Y1.5W-0.28/1.3

0.22

0.28

0.24

0.6

1.3

/

75

Low Voltage

Y1.5W-0.5/2.6

0.38

0.5

0.24

1.2

2.6

/

75

Note:Porcelain

Model

 

Nominal Voltage
(Valid values)

 

Rated Voltage Of Arrester
(Valid values)

 

The Wave Front

Steepness Of The Shock Discharge

 

DC 1mA Reference Voltage

kV Not Less Than

 

1.2/50 Impulse Discharge Voltage

Not Greater Than

 

Wavefront Impulse

Discharge Voltage

 

kV Not Greater Than

The Residual Voltage Under Nominal Discharge

Current 8/20μs

 

kV Not Greater Than

 

2000μs Square

Wave Flow Capacity

 

4/10μs Impulse

Current Capacity

Y5CS-7.6/27

6

7.6

63

16

35

43.8

27

75

25

Y5CZ-7.6/24

6

7.6

63

16

30

37.5

24

150

40

Y5CS-12.7/45

10

12.7

106

26

50

62.5

45

75

25

Y5CS-12.7/41

10

12.7

106

26

45

56.5

41

200

40

Y5CZ-42/124

35

42.0

343

82

134

168

124

200

40

Note: Includes Porcelain Series Gap specification; Incorporates advanced gap specifications for enhanced protection and operational safety.

Installation: Simplified installation process ensures a seamless setup and integration with your existing infrastructure.

(1) Prior to installation, verify the nameplate to ensure the arrester's system rated voltage aligns with the system voltage at the installation location; Confirm compatibility for optimal performance.

(2) Offers flexibility with suspension or vertical installation options. If opting for vertical installation, avoid using the arrester as a load-supporting insulator; Flexible installation options tailored to your specific needs.

(3) Ensure the lead wire is optimized in length to maintain protection efficiency and avoid undue stress on the equipment. Preserve the integrity of your setup with optimal wiring strategies.

Test: Comprehensive testing guidelines ensure enduring reliability and efficiency of your surge arrester over time.

  • lFor enhancing operational reliability, preventive tests are recommended every 4-5 years. Key focus should be on measuring U1mA at both terminals of the DC 1mA arrester. Routine checks ensure sustained performance and longevity.
  • lBefore installation, verify that the U1mA voltage is at least 97% of the original factory value and duly document this data. Initialization ensures optimal setup and functionality from the start.
  • lDuring preventive maintenance, ensure the U1mA voltage does not fall below 26kV. Maintain peak efficiency with regular assessments of voltage levels.
  • lNote: Minimize the harmonic components in the DC power supply for tests. Poor waveforms can result in low U1mA readings. Uphold precise testing standards for accurate results.
  • lThe newly introduced 10kV synthetic insulated zinc oxide arrester for power distribution has successfully passed rigorous lab tests, demonstrating consistent functionality under outdoor line voltage for 15 months. Results confirm: the jacket's excellence, the reliability of the arrester structure, and robust core stability. Coupled with annual performance data from 2,000 units, the product promises superior protection, reduced failure rates, and maintenance-free operation throughout its lifecycle. Experience a leap in power protection with our state-of-the-art arrester, engineered for excellence and reliability.High-Performance Customizable Surge Arrester for Voltage Protection Solutions
Certifications

High-Performance Customizable Surge Arrester for Voltage Protection Solutions

Company Profile

High-Performance Customizable Surge Arrester for Voltage Protection Solutions

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier