Customization: | Available |
---|---|
Type: | High-voltage |
Structure: | Three-column Disconnector |
Still deciding? Get samples of $ !
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
The ZW32-12 outdoor high voltage vacuum circuit breaker, affectionately known as the 'circuit breaker,' is a premier outdoor distribution switchgear developed to operate at a rated voltage of 12kV and a robust three-phase AC of 50Hz. This adaptable circuit breaker proficiently manages the interruption and reconnection of load current, overload current, and short circuit current within the power grid. It features elite-level overload and short circuit protective capabilities, meticulously meeting control and measurement specifications while offering advanced remote control and monitoring functionalities. Its extensive application includes substations, industrial environments, and mining enterprise distribution systems, rendering unparalleled control and operation, ideal for settings that demand frequent operations.
Structural features:
Meticulously crafted with precision, the circuit breaker showcases a sophisticated three-phase pillar dry design;
Designed with an innovative fully enclosed structure, it provides superior sealing, exceptional moisture resistance, and anti-condensation properties, making it an ideal choice for high-temperature and humid regions;
Incorporates cutting-edge vacuum arc extinguishing technology for outstanding insulation reliability;
Ensures flawless opening and closing performance, guaranteeing safety with no risk of combustion or explosion;
Compact, lightweight, requiring virtually no maintenance, and promises an impressive lifespan;
Offers versatility in operation with options for manual, electric, or remote control;
The operating mechanism is meticulously sealed at the base of the switch box, impeccably protecting against outdoor environmental corrosion;
Showcases a novel, simplistic design with a restless mechanism that ensures reliable dynamic performance, compact form, and an astonishing service life of up to 10,000 cycles.
Main technical parameters:
No |
Name |
Unit |
Data |
|||
1 |
Rated voltage |
kV |
12 |
|||
2 |
Rated current |
A |
630 |
1250 |
||
3 |
Rated frequency |
Hz |
50 |
|||
4 |
Rated insulation level |
1min power frequency withstand voltage |
Dry test |
/ |
42/48(fracture) |
|
Wet test |
34 |
|||||
Secondary circuit to ground |
2 |
|||||
Lightning impulse withstand voltage (peak value) |
75/85(fracture) |
|||||
5 |
Rated short circuit making current (peak value) |
kA |
50 |
63 |
||
6 |
Rated short time withstand current |
kA |
20 |
25 |
||
7 |
Rated peak withstand current |
kA |
50 |
63 |
||
8 |
Breaking times of rated short circuit breaking current |
Times |
30 |
|||
9 |
Rated short circuit duration |
s |
4 |
|||
10 |
Rated operating voltage and rated voltage of auxiliary circuit |
V |
DC220,AC220 ,AC/DC220 |
|||
11 |
Rated operation sequence |
/ |
Off-0.3s-on-off-180s-on-off |
|||
12 |
Rated current of over current trip |
A |
5 |
|||
13 |
Mechanical life |
second |
10000 |
|||
14 |
Allowable wear accumulative thickness of moving and static contacts |
mm |
3 |
|||
15 |
Rated current of over current release |
A |
5 |
|||
16 |
Current ratio of current transformer |
/ |
200/5 400/5 600/5 |
|||
17 |
Contact opening distance |
mm |
9±1 |
|||
18 |
Contact overtravel |
mm |
2±0.5 |
|||
19 |
Average opening speed |
m/s |
1.2±0.3 |
|||
20 |
Average closing speed |
m/s |
0.6±0.2 |
|||
21 |
Opening time |
ms |
≤40 |
|||
22 |
Closing time |
ms |
20~45 |
|||
23 |
Closing bounce time |
ms |
≤2 |
|||
24 |
Asynchrony of three phase closing and opening |
mm |
≤2 |
|||
25 |
Three phase circuit resistance |
μΩ |
≤80 Band isolation≤120 |