Customizable Lightning Protection Arrester for Optimal Voltage Surge Control

Product Details
Customization: Available
Type: Power Source Arrester
Structure: Zinc Oxide Arrester
Still deciding? Get samples of $ !
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

OEM Services
The supplier provides OEM services for popular brands
Quality Assurance
The supplier provides quality assurance
Private Mold
The supplier has private mold
Product Certification
The supplier's products already have relevant certification qualifications, including:
CE
to see all verified strength labels (20)
  • Customizable Lightning Protection Arrester for Optimal Voltage Surge Control
  • Customizable Lightning Protection Arrester for Optimal Voltage Surge Control
  • Customizable Lightning Protection Arrester for Optimal Voltage Surge Control
  • Customizable Lightning Protection Arrester for Optimal Voltage Surge Control
  • Customizable Lightning Protection Arrester for Optimal Voltage Surge Control
  • Customizable Lightning Protection Arrester for Optimal Voltage Surge Control
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Certifications
  • Company Profile
Overview

Basic Info.

Model NO.
YH series
Installation
According to Customer Requirements
Application
AC/DC System/Power Plants/Substation
Size
According to Customer Requirements
Operation Voltage
3 - 36kv
Shape
According to Customer Requirements
Material
ZnO
Certification
ROHS, ISO9001, CCC
Brand
Chbeb
Customizable
OEM/According to Customer Requirements
Voltage Customizable
30kv 33kv 36kv
Transport Package
Pallet
Trademark
CHBEB
Origin
China
HS Code
8535400000
Production Capacity
50000 Pieces/Quarter

Product Description

Product Description

Introducing the Zinc Oxide Arrester from Beierbian Group Co., Ltd – a revolutionary, fully sealed, and exceedingly reliable marvel in lightning protection designed specifically for 10kV power distribution systems. This avant-garde device, with its ingenious craftsmanship, employs a zinc oxide valve column, perfectly paired with upper and lower electrodes. All components are seamlessly encased in high-quality silicone rubber, endowing the arrester with unparalleled and impressive characteristics:

  1. This innovative design masterfully resolves the sealing challenges that have traditionally plagued arresters. By ingeniously integrating the core and jacket into a single, compact unit, it completely eradicates any potential cavities that might lead to internal breathing issues, thus overcoming significant technical hurdles associated with preventing moisture ingress into the internal components.
  2. Featuring a robust core with formidable strength to endure internal overvoltage, this arrester exemplifies exceptional resistance to aging. It assures sustained performance and offers unwavering protection over the years, standing as a testament to its long-lasting reliability and endurance.

With its specially engineered valve plate and optimized core parameters, this device ensures the core withstands adversities such as arc grounding, PT resonance, and various operational overvoltages with ease. It operates with unmatched reliability even under line voltage and endures 2.5 to 3 times the power frequency overvoltage. Its voltage withstand duration surpasses international benchmarks by 1 to 3 orders of magnitude, promising unparalleled safety and operational longevity.
Customizable Lightning Protection Arrester for Optimal Voltage Surge Control

Detailed Photos

Customizable Lightning Protection Arrester for Optimal Voltage Surge Control

Customizable Lightning Protection Arrester for Optimal Voltage Surge Control
Customizable Lightning Protection Arrester for Optimal Voltage Surge Control
Customizable Lightning Protection Arrester for Optimal Voltage Surge Control
Customizable Lightning Protection Arrester for Optimal Voltage Surge Control
Customizable Lightning Protection Arrester for Optimal Voltage Surge Control
Customizable Lightning Protection Arrester for Optimal Voltage Surge Control

Product Parameters

Main Characteristics Of Jacket Materials And Product Usage Environment:

Item

Unit

Norm

Shore Hardness A

/

60

Tensile Strength

mpa

≥35

Breaking Elongation

%

≥250

Oxygen Index

/

45

Resistivity

Ω.m

≥1×1013

Breakdown Strength

MV/m

≥25

Tracking

kV

4.5

Durability

Not less than 20 years

Working Environment:

Specifically engineered for flawless performance in both indoor and outdoor settings,

Exhibits efficient functionality at impressive altitudes reaching up to 3000 meters,

Remarkably resilient to ambient temperatures, enduring from a frosty -40C to a warm +60C,

Seamlessly adapts to power supply frequencies, ranging from a stable 48Hz to a lively 62Hz,

Assures that the power frequency voltage applied between terminals adheres to optimal thresholds, ensuring extended usability.

Designed to withstand seismic forces with intensities not surpassing 8 degrees.

Meticulously crafted to resist powerful wind speeds up to 35 meters per second, ensuring reliability even in turbulent conditions.

Note:

For conditions that exceed the usual operational parameters, our team stands ready to provide bespoke solutions tailored to your needs.

Main technical parameters

Model

Nominal Voltage

(rms)

Rated Voltage OArrester

(rms)

Continuous Operating Voltage

(rms)

DC 1mA reference voltage
kV not less than

The residual voltage under nominal discharge current
kV (Crest) not greater than

Steep wave impact residual voltage
kV (Crest) not greater than

2ms square wave flow capacity
A

Operation Place

YH5WS-3.8/17

3

3.8

2.0

7.5

17.0

19.6

100

 

Distribution Type

YH5WS-5/15

3

5

4.0

7.5

15.0

17.3

150

YH5WS-7.6/30

6

7.6

4.0

15.0

15.0

34.5

100

YH5WS-10/30

6

10

8.0

15.0

30.0

34.6

150

YH5WS-12.7/50

10

12.7

10

26.0

50.0

57.5

100

YH5WS-16.5/50

10

16.5

12.7

26.0

50.0

57.5

100

YH5WS-17/50

10

17

13.6

26.0

50.0

57.5

150

YH5WS-17/45

10

17

13.6

25.0

45.0

/

250

YH10WS-17/45

10

17

13.6

25.0

45.0

/

400

YH5WZ-5/13.5

3

5

4.0

7.2

13.5

15.5

200

Power Station Type

YH5WZ-7.6/27

6

7.6

4.0

14.4

27.0

31.0

150

YH5WZ-10/27

6

10

8.0

14.4

27.0

31.0

200

YH5WZ-42/134

35

42

23.4

73

134

154

150

YH5WZ-12.7/45

10

12.7

6.6

24.0

45.0

51.8

150

YH5WZ-16.5/45

10

16.5

13.2

24.0

45.0

51.8

150

YH5WZ-17/45

10

17

13.6

24.0

45.0

51.8

200

YH5WZ-51/134

35

51

40.8

73.0

134

154

400

YH10WZ-17/45

10

17

13.6

24.0

45.0

51.8

200

YH10WZ-51/134

35

51

40.8

73.0

134

154

400

YH5WR-5/13.5

3

5

4.0

7.2

13.5

/

400

Capacitive Type

YH5WR-7.6/27

6

7.6

4.0

13.8

27.0

/

400

YH5WR-10/27

6

10

8.0

14.4

27.0

/

400

YH5WR-12.7/45

10

12.7

6.6

23.0

45.0

/

400

YH5WR 17/45

10

17

13.6

24.0

45.0

/

400

YH5WX-51/134

35

51

40.8

73

134.0

154

400

Line type

YH1.5W-30/80

35

30

24

44

80.0

/

600

Neutral Type

Note: Constructed with a durable and robust Polymeric build

Model

Nominal Voltage

(rms)

Rated Voltage OArrester

(rms)

Continuous Operating Voltage

(rms)

DC 1mA Reference Voltage
kV Not Less Than

The Residual Voltage Under Nominal Discharge Current
kV (Crest)
Not Greater Than

Steep Wave Impact Residual Voltage
kV (Crest)
Not Greater Than

2ms Square Wave Flow Capacity
A

Operation Place

Y5WS-5/15

3

5

4.0

7.5

15.0

17.3

150

Distribution Type

Y5WS-7.6/30

6

7.6

4.0

15.0

15.0

34.5

100

Y5WS-10/30

6

10

8.0

15.0

30.0

34.6

150

Y5WS-12.7/50

10

12.7

10

26.0

50.0

57.5

100

Y5WS-16.5/50

10

16.5

12.7

26.0

50.0

57.5

100

Y5WS-17/50

10

17

13.6

26.0

50.0

57.5

150

Y5WZ-5/13.5

3

5

4.0

7.2

13.5

15.5

200

Power Station Type

Y5WZ-7.6/27

6

7.6

4.0

14.4

27.0

31.0

150

Y5WZ-10/27

6

10

8.0

14.4

27.0

31.0

200

Y5WZ-42/134

35

42

23.4

73

134

154

150

Y5WZ-12.7/45

10

12.7

6.6

24.0

45.0

51.8

150

Y5WZ-16.5/45

10

16.5

13.2

24.0

45.0

51.8

150

Y5WZ-17/45

10

17

13.6

24.0

45.0

51.8

200

Y5WZ-51/134

35

51

40.8

73.0

134

154

400

Y5WR-5/13.5

3

5

4.0

7.2

13.5

/

400

Capacitive Type

Y5WR-7.6/27

6

7.6

4.0

13.8

27.0

/

400

Y5WR-10/27

6

10

8.0

14.4

27.0

/

400

Y5WR-12.7/45

10

12.7

6.6

23.0

45.0

/

400

Y5WR-17/45

10

17

13.6

24.0

45.0

/

400

Y1.5W-0.28/1.3

0.22

0.28

0.24

0.6

1.3

/

75

Low Voltage

Y1.5W-0.5/2.6

0.38

0.5

0.24

1.2

2.6

/

75

Note:Porcelain

Model

 

Nominal Voltage
(Valid values)

 

Rated Voltage Of Arrester
(Valid values)

 

The Wave Front

Steepness Of The Shock Discharge

 

DC 1mA Reference Voltage

kV Not Less Than

 

1.2/50 Impulse Discharge Voltage

Not Greater Than

 

Wavefront Impulse

Discharge Voltage

 

kV Not Greater Than

The Residual Voltage Under Nominal Discharge

Current 8/20μs

 

kV Not Greater Than

 

2000μs Square

Wave Flow Capacity

 

4/10μs Impulse

Current Capacity

Y5CS-7.6/27

6

7.6

63

16

35

43.8

27

75

25

Y5CZ-7.6/24

6

7.6

63

16

30

37.5

24

150

40

Y5CS-12.7/45

10

12.7

106

26

50

62.5

45

75

25

Y5CS-12.7/41

10

12.7

106

26

45

56.5

41

200

40

Y5CZ-42/124

35

42.0

343

82

134

168

124

200

40

Note: Incorporates Porcelain Series Gap specification for enhanced performance

Installation

(1) Prior to installation, it is crucial to check the nameplate to confirm the arrester's system rated voltage matches the system voltage at the intended installation site.

(2) Offers installation versatility with both suspension and vertical setups. For vertical installation, ensure not to use the arrester as a load-bearing insulator.

(3) Keep the lead wire optimized in length to ensure maximum protection efficiency and prevent unnecessary equipment strain.

Test

  • lTo bolster operational reliability, it's advisable to conduct preventive tests every 4-5 years, with emphasis on measuring U1mA at both DC 1mA arrester terminals.
  • lBefore installation, ensure the U1mA voltage reaches a minimum of 97% of the original factory value, and accurately record this data.
  • lDuring preventive maintenance, verify that the U1mA voltage does not dip below 26kV.
  • lNote: Minimize harmonic distortion in the DC power supply during tests, as poor waveforms can lead to reduced U1mA readings.
  • lThe innovative 10kV synthetic insulated zinc oxide arrester, designed for power distribution, has undergone exhaustive laboratory testing, proving its steadfast functionality under outdoor line voltage for 15 months. The findings highlight: the unparalleled quality of the jacket, the structural reliability of the arrester, and the robust stability of the core. Supported by annual performance metrics from 2,000 units, this product guarantees unmatched protection, decreased failure rates, and maintenance-free operation throughout its lifecycle.Customizable Lightning Protection Arrester for Optimal Voltage Surge Control
Certifications

Customizable Lightning Protection Arrester for Optimal Voltage Surge Control

Company Profile

Customizable Lightning Protection Arrester for Optimal Voltage Surge Control

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier