Customization: | Available |
---|---|
Breaking Capacity: | 12kv/24kv/40.5kv |
Type: | Current Fuse |
Still deciding? Get samples of $ !
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
(H) RW(F) series outdoor high voltage AC drop fuse (hereinafter referred to as 'fuse') is ingeniously crafted for outdoor overhead distribution systems with a rated frequency of 50Hz and a robust rated voltage of 10kV (12/15/35/40.5). This sophisticated device acts as a guardian for circuits or electrical equipment during overloads or short circuits in power systems. Under normal operations, the fuse integrates seamlessly in series within the power line, maintaining a taut and secured position. Upon detecting a system fault, the ensuing fault current prompts the fuse to disengage, releasing the movable joint and swiftly severing the circuit to ensure safety and facilitate maintenance of the line and equipment. Enhancing the ordinary model, the load type fuse features an elastic contact and an innovative arc extinguishing cover, adeptly managing the load current in the power system with precision.
The fuse is meticulously designed to adhere to esteemed technical standards, including GB / T 15166.3 - 2008 for high voltage AC fuses - Part 3: injection fuses, and DL / T 640 - 1997, governing outdoor AC high voltage drop-tested fuses and fuse links ordering technical conditions.
Working Environment:
Ambient temperature: Ranges from a frosty -40°C to a warm +40°C;
Relative humidity: Ensures optimal performance with a daily average not exceeding 95%, and a monthly average not beyond 90%;
Altitude: Suitable for regions where the elevation does not surpass 3000 meters;
Outdoor wind speed: Engineered to withstand speeds up to 34 meters/second;
Installation site: Ideal installation in environments devoid of fire, explosion hazards, chemical corrosive gases, ensuring well-ventilated conditions.
Note: Should your operational conditions deviate from the norm, a personalized consultation with our company is encouraged to explore viable solutions.
Technical parameters
Note: Our company is committed to customizing product solutions tailored to meet unique user requirements.
Model |
Voltage |
Current |
Rated maximum
breaking current |
1min power frequency dry withstand
voltage |
1min power frequency wet withstand
voltage |
Rated lightning impulse withstand
voltage |
Opening and closing
load current |
XS-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
XS-15/100(200) |
15 |
||||||
PD-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
PD-15/100(200) |
15 |
||||||
(H)RW3-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW3-12/100(200) |
12 |
||||||
(H)RW4-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW4-12/100(200) |
12 |
||||||
(H)RW7-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW7-12/100(200) |
12 |
||||||
(H)RW10-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW10-12/100(200) |
12 |
||||||
(H)RW10-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW10-12F/100(200) |
12 |
||||||
(H)RW11-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
! |
(H)RW11-12/100(200) |
12 |
||||||
(H)RW11-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW11-12F/100(200) |
12 |
||||||
(H)RW12-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
45 |
30 |
105 |
/ |
(H)RW12-12/100(200) |
12 |
||||||
(H)RW12-15/100(200) |
15 |
||||||
(H)PRWG1-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)PRWG1-12F/100(200) |
12 |
||||||
(H)RW33-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW33-15/100(200) |
15 |
||||||
(H)RW5-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)RW10-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)PRWG2-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |