Customization: | Available |
---|---|
Breaking Capacity: | 12kv/24kv/40.5kv |
Type: | Current Fuse |
Still deciding? Get samples of US$ 30/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
(H) RW(F) series outdoor high voltage AC drop fuse, henceforth referred to as the 'fuse', is expertly designed for outdoor overhead distribution systems with a rated frequency of 50Hz and a rated voltage of 10kV (12/15/35/40.5). Serving as a vital protective component, this fuse acts as a safeguard for circuits and electrical equipment during overloads or short circuits within the power grid. Integrated seamlessly into the power line under normal conditions, the fuse remains under tension, securely locking the movable joint. Upon encountering a fault, the surge of fault current swiftly blows the fuse, releasing the movable joint, and promptly dropping the fuse tube to disconnect the circuit. This crucial function ensures comprehensive safety protection for the maintenance and operation of lines and equipment. Enhanced with an elastic contact and an arc extinguishing cover, the load type fuse is specifically engineered to efficiently open and close the load current within the power system, elevating your safety assurance.
This fuse meets rigorous technical standards such as GB / T 15166.3 - 2008 for high voltage AC fuses - Part 3: injection fuses, as well as DL / T 640 - 1997 for outdoor AC high voltage drop tested fuses and fuse links ordering technical conditions, ensuring reliability and excellence.
Working Environment:
Ambient temperature: Between -40°C and +40°C; a wide range that accommodates various climatic conditions.
Relative humidity: Daily average not exceeding 95%, and a monthly average capped at 90%; ensuring product integrity in humid environments.
Altitude: Suitable for installations where the altitude does not surpass 3000 meters, maintaining optimal performance.
Outdoor wind speed: Capable of withstanding wind speeds up to 34 meters/second, ensuring durability in windy conditions.
Installation site: Appropriate for locations free from fire, explosion hazards, chemical corrosive gases, and ensuring a well-ventilated environment.
Note: Should your use conditions exceed the parameters listed above, we welcome negotiations to customize solutions to meet your specific needs.
Technical parameters
Note: Our company is committed to providing tailored products to align with your specific requirements.
Model |
Voltage |
Current |
Rated maximum
breaking current |
1min power frequency dry withstand
voltage |
1min power frequency wet withstand
voltage |
Rated lightning impulse withstand
voltage |
Opening and closing
load current |
XS-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
XS-15/100(200) |
15 |
||||||
PD-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
PD-15/100(200) |
15 |
||||||
(H)RW3-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW3-12/100(200) |
12 |
||||||
(H)RW4-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW4-12/100(200) |
12 |
||||||
(H)RW7-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW7-12/100(200) |
12 |
||||||
(H)RW10-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW10-12/100(200) |
12 |
||||||
(H)RW10-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW10-12F/100(200) |
12 |
||||||
(H)RW11-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
! |
(H)RW11-12/100(200) |
12 |
||||||
(H)RW11-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW11-12F/100(200) |
12 |
||||||
(H)RW12-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
45 |
30 |
105 |
/ |
(H)RW12-12/100(200) |
12 |
||||||
(H)RW12-15/100(200) |
15 |
||||||
(H)PRWG1-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)PRWG1-12F/100(200) |
12 |
||||||
(H)RW33-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW33-15/100(200) |
15 |
||||||
(H)RW5-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)RW10-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)PRWG2-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |