Customization: | Available |
---|---|
Type: | High-voltage |
Structure: | Three-column Disconnector |
Still deciding? Get samples of US$ 800/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Introducing the ZW32-12 Outdoor High Voltage Vacuum Circuit Breaker, your ultimate solution for modern outdoor distribution networks. Affectionately known as the 'circuit breaker,' this superior switchgear is engineered for a 12kV rated voltage and a robust three-phase AC at 50Hz. This impressive circuit breaker excels in seamlessly interrupting and reconnecting load current, managing overload current, and handling short circuit current within power grids. It showcases cutting-edge overload and short circuit protective abilities, effortlessly meeting control and measurement demands while offering sophisticated remote control and monitoring functions. Its extensive application range includes substations, industrial settings, and mining enterprise distribution systems, making it the premier choice for environments requiring frequent operations. This ensures unparalleled control and efficiency, providing an invaluable asset for contemporary electrical infrastructures.
Structural Features:
Meticulously crafted with precision, the circuit breaker boasts a refined three-phase pillar dry design;
Expertly engineered with a fully enclosed structure, it delivers outstanding sealing, exceptional moisture resistance, and anti-condensation qualities, perfect for high-temperature and humid environments;
Employs state-of-the-art vacuum arc extinguishing technology, offering extraordinary insulation reliability;
Ensures flawless opening and closing performance, guaranteeing safety with zero risk of combustion or explosion;
Designed to be compact and lightweight, this advanced device is maintenance-free, boasting an impressive lifespan;
Features versatile operation capabilities, with manual, electric, or remote control options available for ultimate convenience;
The operating mechanism is meticulously sealed at the switch box's base, effectively shielding against outdoor environmental corrosion;
Showcases an innovative and streamlined design featuring a restless mechanism, ensuring reliable dynamic performance, a compact structure, and an incredible service life reaching up to 10,000 cycles.
Main Technical Parameters:
No |
Name |
Unit |
Data |
|||
1 |
Rated voltage |
kV |
12 |
|||
2 |
Rated current |
A |
630 |
1250 |
||
3 |
Rated frequency |
Hz |
50 |
|||
4 |
Rated insulation level |
1min power frequency withstand voltage |
Dry test |
/ |
42/48(fracture) |
|
Wet test |
34 |
|||||
Secondary circuit to ground |
2 |
|||||
Lightning impulse withstand voltage (peak value) |
75/85(fracture) |
|||||
5 |
Rated short circuit making current (peak value) |
kA |
50 |
63 |
||
6 |
Rated short time withstand current |
kA |
20 |
25 |
||
7 |
Rated peak withstand current |
kA |
50 |
63 |
||
8 |
Breaking times of rated short circuit breaking current |
Times |
30 |
|||
9 |
Rated short circuit duration |
s |
4 |
|||
10 |
Rated operating voltage and rated voltage of auxiliary circuit |
V |
DC220,AC220 ,AC/DC220 |
|||
11 |
Rated operation sequence |
/ |
Off-0.3s-on-off-180s-on-off |
|||
12 |
Rated current of over current trip |
A |
5 |
|||
13 |
Mechanical life |
second |
10000 |
|||
14 |
Allowable wear accumulative thickness of moving and static contacts |
mm |
3 |
|||
15 |
Rated current of over current release |
A |
5 |
|||
16 |
Current ratio of current transformer |
/ |
200/5 400/5 600/5 |
|||
17 |
Contact opening distance |
mm |
9±1 |
|||
18 |
Contact overtravel |
mm |
2±0.5 |
|||
19 |
Average opening speed |
m/s |
1.2±0.3 |
|||
20 |
Average closing speed |
m/s |
0.6±0.2 |
|||
21 |
Opening time |
ms |
≤40 |
|||
22 |
Closing time |
ms |
20~45 |
|||
23 |
Closing bounce time |
ms |
≤2 |
|||
24 |
Asynchrony of three phase closing and opening |
mm |
≤2 |
|||
25 |
Three phase circuit resistance |
μΩ |
≤80 Band isolation≤120 |