Customizable Lightning Surge Arrester Solutions with Polymeric Housing Options

Product Details
Customization: Available
Type: Power Source Arrester
Structure: Zinc Oxide Arrester
Still deciding? Get samples of US$ 35/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

OEM Services
The supplier provides OEM services for popular brands
Quality Assurance
The supplier provides quality assurance
Private Mold
The supplier has private mold
Product Certification
The supplier's products already have relevant certification qualifications, including:
CE
to see all verified strength labels (20)
  • Customizable Lightning Surge Arrester Solutions with Polymeric Housing Options
  • Customizable Lightning Surge Arrester Solutions with Polymeric Housing Options
  • Customizable Lightning Surge Arrester Solutions with Polymeric Housing Options
  • Customizable Lightning Surge Arrester Solutions with Polymeric Housing Options
  • Customizable Lightning Surge Arrester Solutions with Polymeric Housing Options
  • Customizable Lightning Surge Arrester Solutions with Polymeric Housing Options
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Certifications
  • Company Profile
Overview

Basic Info.

Model NO.
YH series
Installation
According to Customer Requirements
Application
AC/DC System/Power Plants/Substation
Size
According to Customer Requirements
Operation Voltage
3 - 36kv
Shape
According to Customer Requirements
Material
ZnO
Certification
ROHS, ISO9001, CCC
Brand
Chbeb
Customizable
OEM/According to Customer Requirements
Voltage Customizable
30kv 33kv 36kv
Transport Package
Pallet
Trademark
CHBEB
Origin
China
HS Code
8535400000
Production Capacity
50000 Pieces/Quarter

Product Description

Product Description

Introducing the Zinc Oxide Arrester from Beierbian Group Co., Ltd—a revolutionary marvel in lightning protection for 10kV power distribution systems. This fully sealed, exceedingly reliable device is a masterpiece of engineering, crafted with a zinc oxide valve column and complemented by upper and lower electrodes. Encapsulated seamlessly in silicone rubber, it offers unparalleled performance and reliability through innovative design and exceptional materials, making it the ultimate solution for your power system's lightning protection needs.

  1. This cutting-edge design masterfully tackles and triumphs over the traditional sealing challenges faced by arresters. By ingeniously integrating the core and jacket into a unified, compact entity, it eradicates potential cavities that could lead to internal breathing issues. This brilliant innovation effectively overcomes the technical hurdles associated with shielding internal components from moisture ingress, ensuring a robust and durable solution.
  2. With a robust core crafted to endure internal overvoltage with ease, this arrester stands out with its exceptional resistance to aging. It guarantees sustained performance and unwavering protection, promising reliability and peace of mind for years to come, regardless of environmental conditions.

Enhanced with a specially engineered valve plate and optimized core parameters, this device ensures the core withstands challenges like arc grounding, PT resonance, and a range of operational overvoltages. It operates with exceptional reliability under line voltage and endures 2.5 to 3 times the power frequency overvoltage. Its duration in withstanding voltage exceeds international standards by 1 to 3 orders of magnitude, assuring top-tier safety and operational longevity, firmly establishing a new benchmark in the industry.
Customizable Lightning Surge Arrester Solutions with Polymeric Housing Options

Detailed Photos

Customizable Lightning Surge Arrester Solutions with Polymeric Housing Options

Customizable Lightning Surge Arrester Solutions with Polymeric Housing Options
Customizable Lightning Surge Arrester Solutions with Polymeric Housing Options
Customizable Lightning Surge Arrester Solutions with Polymeric Housing Options
Customizable Lightning Surge Arrester Solutions with Polymeric Housing Options
Customizable Lightning Surge Arrester Solutions with Polymeric Housing Options
Customizable Lightning Surge Arrester Solutions with Polymeric Housing Options

Product Parameters

Main Characteristics Of Jacket Materials And Product Usage Environment:

Item

Unit

Norm

Shore Hardness A

/

60

Tensile Strength

mpa

≥35

Breaking Elongation

%

≥250

Oxygen Index

/

45

Resistivity

Ω.m

≥1×1013

Breakdown Strength

MV/m

≥25

Tracking

kV

4.5

Durability

Not less than 20 years

Working Environment:

Meticulously crafted for flawless performance in both indoor and outdoor settings;

Achieves outstanding functionality at impressive altitudes reaching up to 3000 meters;

Expertly engineered to endure extreme temperatures from a frigid -40°C to a warm +60°C;

Seamlessly compatible with power frequencies ranging from a stable 48Hz to an active 62Hz;

Guarantees that power frequency voltage between terminals is consistently maintained within ideal thresholds for extended usage.

Designed to withstand seismic activities up to a magnitude of 8 degrees effortlessly.

Expertly engineered to resist formidable outdoor wind speeds reaching an impressive 35 meters per second;

Note:

Should you face conditions beyond these standard operational parameters, do not hesitate to reach out and explore customized solutions with our expert team.

Main Technical Parameters

Model

Nominal Voltage

(rms)

Rated Voltage OArrester

(rms)

Continuous Operating Voltage

(rms)

DC 1mA reference voltage
kV not less than

The residual voltage under nominal discharge current
kV (Crest) not greater than

Steep wave impact residual voltage
kV (Crest) not greater than

2ms square wave flow capacity
A

Operation Place

YH5WS-3.8/17

3

3.8

2.0

7.5

17.0

19.6

100

 

Distribution Type

YH5WS-5/15

3

5

4.0

7.5

15.0

17.3

150

YH5WS-7.6/30

6

7.6

4.0

15.0

15.0

34.5

100

YH5WS-10/30

6

10

8.0

15.0

30.0

34.6

150

YH5WS-12.7/50

10

12.7

10

26.0

50.0

57.5

100

YH5WS-16.5/50

10

16.5

12.7

26.0

50.0

57.5

100

YH5WS-17/50

10

17

13.6

26.0

50.0

57.5

150

YH5WS-17/45

10

17

13.6

25.0

45.0

/

250

YH10WS-17/45

10

17

13.6

25.0

45.0

/

400

YH5WZ-5/13.5

3

5

4.0

7.2

13.5

15.5

200

Power Station Type

YH5WZ-7.6/27

6

7.6

4.0

14.4

27.0

31.0

150

YH5WZ-10/27

6

10

8.0

14.4

27.0

31.0

200

YH5WZ-42/134

35

42

23.4

73

134

154

150

YH5WZ-12.7/45

10

12.7

6.6

24.0

45.0

51.8

150

YH5WZ-16.5/45

10

16.5

13.2

24.0

45.0

51.8

150

YH5WZ-17/45

10

17

13.6

24.0

45.0

51.8

200

YH5WZ-51/134

35

51

40.8

73.0

134

154

400

YH10WZ-17/45

10

17

13.6

24.0

45.0

51.8

200

YH10WZ-51/134

35

51

40.8

73.0

134

154

400

YH5WR-5/13.5

3

5

4.0

7.2

13.5

/

400

Capacitive Type

YH5WR-7.6/27

6

7.6

4.0

13.8

27.0

/

400

YH5WR-10/27

6

10

8.0

14.4

27.0

/

400

YH5WR-12.7/45

10

12.7

6.6

23.0

45.0

/

400

YH5WR 17/45

10

17

13.6

24.0

45.0

/

400

YH5WX-51/134

35

51

40.8

73

134.0

154

400

Line type

YH1.5W-30/80

35

30

24

44

80.0

/

600

Neutral Type

Note: Distinguished by its robust Polymeric construction

Model

Nominal Voltage

(rms)

Rated Voltage OArrester

(rms)

Continuous Operating Voltage

(rms)

DC 1mA Reference Voltage
kV Not Less Than

The Residual Voltage Under Nominal Discharge Current
kV (Crest)
Not Greater Than

Steep Wave Impact Residual Voltage
kV (Crest)
Not Greater Than

2ms Square Wave Flow Capacity
A

Operation Place

Y5WS-5/15

3

5

4.0

7.5

15.0

17.3

150

Distribution Type

Y5WS-7.6/30

6

7.6

4.0

15.0

15.0

34.5

100

Y5WS-10/30

6

10

8.0

15.0

30.0

34.6

150

Y5WS-12.7/50

10

12.7

10

26.0

50.0

57.5

100

Y5WS-16.5/50

10

16.5

12.7

26.0

50.0

57.5

100

Y5WS-17/50

10

17

13.6

26.0

50.0

57.5

150

Y5WZ-5/13.5

3

5

4.0

7.2

13.5

15.5

200

Power Station Type

Y5WZ-7.6/27

6

7.6

4.0

14.4

27.0

31.0

150

Y5WZ-10/27

6

10

8.0

14.4

27.0

31.0

200

Y5WZ-42/134

35

42

23.4

73

134

154

150

Y5WZ-12.7/45

10

12.7

6.6

24.0

45.0

51.8

150

Y5WZ-16.5/45

10

16.5

13.2

24.0

45.0

51.8

150

Y5WZ-17/45

10

17

13.6

24.0

45.0

51.8

200

Y5WZ-51/134

35

51

40.8

73.0

134

154

400

Y5WR-5/13.5

3

5

4.0

7.2

13.5

/

400

Capacitive Type

Y5WR-7.6/27

6

7.6

4.0

13.8

27.0

/

400

Y5WR-10/27

6

10

8.0

14.4

27.0

/

400

Y5WR-12.7/45

10

12.7

6.6

23.0

45.0

/

400

Y5WR-17/45

10

17

13.6

24.0

45.0

/

400

Y1.5W-0.28/1.3

0.22

0.28

0.24

0.6

1.3

/

75

Low Voltage

Y1.5W-0.5/2.6

0.38

0.5

0.24

1.2

2.6

/

75

Note:Porcelain

Model

 

Nominal Voltage
(Valid values)

 

Rated Voltage Of Arrester
(Valid values)

 

The Wave Front

Steepness Of The Shock Discharge

 

DC 1mA Reference Voltage

kV Not Less Than

 

1.2/50 Impulse Discharge Voltage

Not Greater Than

 

Wavefront Impulse

Discharge Voltage

 

kV Not Greater Than

The Residual Voltage Under Nominal Discharge

Current 8/20μs

 

kV Not Greater Than

 

2000μs Square

Wave Flow Capacity

 

4/10μs Impulse

Current Capacity

Y5CS-7.6/27

6

7.6

63

16

35

43.8

27

75

25

Y5CZ-7.6/24

6

7.6

63

16

30

37.5

24

150

40

Y5CS-12.7/45

10

12.7

106

26

50

62.5

45

75

25

Y5CS-12.7/41

10

12.7

106

26

45

56.5

41

200

40

Y5CZ-42/124

35

42.0

343

82

134

168

124

200

40

Note: Incorporates Porcelain Series Gap specifications for enhanced performance

Installation

(1) Before proceeding with installation, ensure you verify the nameplate to confirm that the arrester's system rated voltage corresponds with the system voltage at the designated installation site;

(2) Offers versatile installation options, including both suspension and vertical placements. For vertical installations, ensure the arrester is not used as a load-bearing insulator;

(3) Optimize the lead wire length to maintain superior protection efficiency and prevent undue equipment stress.

Test

  • lTo enhance operational reliability, it's advisable to conduct preventive tests every 4-5 years, focusing on measuring U1mA at both terminals of the DC 1mA arrester.
  • lPrior to installation, confirm that the U1mA voltage is at a minimum of 97% of the original factory value and ensure this data is properly documented.
  • lDuring preventive maintenance, verify that the U1mA voltage remains above 26kV.
  • lNote: Minimize harmonic components in the DC power supply during testing as poor waveforms can lead to inaccurate U1mA readings.
  • lThe newly released 10kV synthetic insulated zinc oxide arrester for power distribution has undergone extensive lab testing, proving consistent functionality under outdoor line voltage conditions over 15 months. Results confirm: the jacket's superior quality, the arrester's structural reliability, and the core's robust stability. Combined with annual performance data from 2,000 units, this product ensures unparalleled protection, reduced failure incidents, and a maintenance-free lifespan.Customizable Lightning Surge Arrester Solutions with Polymeric Housing Options
Certifications

Customizable Lightning Surge Arrester Solutions with Polymeric Housing Options

Company Profile

Customizable Lightning Surge Arrester Solutions with Polymeric Housing Options

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier