Medium Voltage Load Break Disconnect Switch Outdoor Isolator 12kv

Product Details
Customization: Available
Type: 10kv/12kv/15kv
Structure: According to Customer Requirements
Still deciding? Get samples of US$ 140/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

OEM Services
The supplier provides OEM services for popular brands
Quality Assurance
The supplier provides quality assurance
Private Mold
The supplier has private mold
Product Certification
The supplier's products already have relevant certification qualifications, including:
CE
to see all verified strength labels (20)
  • Medium Voltage Load Break Disconnect Switch Outdoor Isolator 12kv
  • Medium Voltage Load Break Disconnect Switch Outdoor Isolator 12kv
  • Medium Voltage Load Break Disconnect Switch Outdoor Isolator 12kv
  • Medium Voltage Load Break Disconnect Switch Outdoor Isolator 12kv
  • Medium Voltage Load Break Disconnect Switch Outdoor Isolator 12kv
  • Medium Voltage Load Break Disconnect Switch Outdoor Isolator 12kv
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Certifications
Overview

Basic Info.

Model NO.
(H)GWBEB
Installation
Outdoor High-voltage
Operation
Manual/Electric/Pneumatic/Hydraulic
Grounding Mode
According to Customer Requirements
Movement Mode
According to Customer Requirements
Number of Poles
According to Customer Requirements
Grounding
According to Customer Requirements
Series
Two
Run
According to Customer Requirements
Switching Mode
According to Customer Requirements
Common Model
Gw9
Structure of Operating
According to Customer Requirements
Certification
ISO, RoHS, CE
Brand
Chbeb
Customizable
OEM/According to Customer Requirements
Transport Package
Standard Shipping Packing
Specification
45*55*38mm
Trademark
CHBEB
Origin
China
HS Code
853530900
Production Capacity
5000 PCS/Quarter

Product Description

Medium Voltage Load Break Disconnect Switch Outdoor Isolator 12kv
Product Description

Introducing the (H)GWBEB type outdoor high-voltage isolation switch, a pinnacle of engineering excellence, also known as an isolation disconnect switch. This marvel is meticulously crafted for high voltage power transmission and distribution lines operating at 10(12, 15, 24)kV. Perfectly suited for seamlessly opening and closing single-phase or three-phase circuits with voltage present, yet impeccably without load, it boasts reliability and precision in every switch.

Tailored for single-phase applications within three-phase line systems, our switch stands out with its elegantly simple structure, remarkable cost-efficiency, and user-friendly operation. It offers a variety of rated currents including 200, 400, 600, 800, 1000, and 1250 amps, ensuring versatility for diverse requirements. The switch comprises a robust base, durable post insulators, high-quality conductive parts, and a sophisticated mechanical section. Utilizing an innovative gate knife structure, it assures smooth circuit opening and closing. Each phase's gate knife is engineered with two conductive blades and external compression springs on both sides, enabling precise adjustment of spring height to achieve optimal contact pressure. Operable via an insulated hook stick, it features a self-locking device to ensure safety and reliability.

Working Environment:

Altitude not exceeding 1000 meters;

Ambient temperature: maximum not exceeding +40°C; minimum not falling below -30°C;

Outdoor wind speed not exceeding 35 meters/second;

Withstands seismic intensity up to 8 degrees; installation sites should not be prone to frequent severe vibrations.

Installation sites must be free of gases, chemical deposits, salt mist, dust, dirt, or other explosive or corrosive mediums that could significantly impair the switch's insulation and conductivity.

Note:

FOR CONDITIONS EXCEEDING THE ABOVE STANDARDS OF NORMAL USE, USERS ARE ENCOURAGED TO CONSULT WITH THE COMPANY FOR TAILORED SOLUTIONS.

Installation, Use and Adjustment

Pre-installation work

  1. Diligently remove dust and dirt from all parts, and meticulously clean the surface of the insulating porcelain bottle to ensure pristine condition.
  2. Thoroughly scrub the wiring surface of the ground screw to ensure optimal connectivity.
  3. Apply a protective layer of industrial Vaseline to all rotating parts and contact areas for smooth operation and prolonged durability.
  4. Inspect the contact surface and skillfully adjust the height of the compression spring to ensure the contact pressure aligns perfectly with Table II specifications.
  5. This switch is exclusively designed for hoisting applications and is perfectly harmonized for use alongside transformers on the line, offering unmatched compatibility.
  6. For the 200-400 ampere hours range, the switch typically requires three mounting holes, while the robust 600-1000A range is also accommodated with three mounting holes.

Conduct an annual inspection of the following switch components:
Meticulously clean dirt from conductive parts, contact surfaces, and the insulating porcelain bottle surface to maintain functionality.

Inspect all components for signs of damage, with particular focus on the insulating porcelain bottle for cracks or damage, ensuring continued safety and performance.

Verify the integrity of the conductive part's contact surface to guarantee seamless operation.


Medium Voltage Load Break Disconnect Switch Outdoor Isolator 12kv

Detailed Photos

Medium Voltage Load Break Disconnect Switch Outdoor Isolator 12kv
Medium Voltage Load Break Disconnect Switch Outdoor Isolator 12kv
Medium Voltage Load Break Disconnect Switch Outdoor Isolator 12kv
Medium Voltage Load Break Disconnect Switch Outdoor Isolator 12kv


Medium Voltage Load Break Disconnect Switch Outdoor Isolator 12kv
Medium Voltage Load Break Disconnect Switch Outdoor Isolator 12kv

Medium Voltage Load Break Disconnect Switch Outdoor Isolator 12kv
Medium Voltage Load Break Disconnect Switch Outdoor Isolator 12kv
Medium Voltage Load Break Disconnect Switch Outdoor Isolator 12kv
Medium Voltage Load Break Disconnect Switch Outdoor Isolator 12kv
Medium Voltage Load Break Disconnect Switch Outdoor Isolator 12kv
Medium Voltage Load Break Disconnect Switch Outdoor Isolator 12kv
Medium Voltage Load Break Disconnect Switch Outdoor Isolator 12kv
Medium Voltage Load Break Disconnect Switch Outdoor Isolator 12kv
Medium Voltage Load Break Disconnect Switch Outdoor Isolator 12kv
Medium Voltage Load Break Disconnect Switch Outdoor Isolator 12kv
Medium Voltage Load Break Disconnect Switch Outdoor Isolator 12kv
Medium Voltage Load Break Disconnect Switch Outdoor Isolator 12kv

Product Parameters

The main technical parameters

Table I

Model

Rated voltage
kV

 

Rated current
A

kA

 

10 seconds thermal stable current
kA

peak

Valid values

 

(H)GW

 

10

12

15

200

5

9

5

400

21

15

10

600

35

25

14

630

35

25

14

800

35

25

14

1000

50

35

20

Contact force parameters

Table II

Model

Rated current(A)

contact pressure(kgf)

(H)GW

5

9

21

15

35

25

35

25

35

25

50

35

Certifications

Medium Voltage Load Break Disconnect Switch Outdoor Isolator 12kvMedium Voltage Load Break Disconnect Switch Outdoor Isolator 12kv

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier