Customizable Surge Arrester for High Voltage Lightning Protection Needs

Product Details
Customization: Available
Type: Power Source Arrester
Structure: Zinc Oxide Arrester
Still deciding? Get samples of US$ 35/Piece
Request Sample
Manufacturer/Factory

360° Virtual Tour

Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

OEM Services
The supplier provides OEM services for popular brands
Quality Assurance
The supplier provides quality assurance
Private Mold
The supplier has private mold
Product Certification
The supplier's products already have relevant certification qualifications, including:
CE
to see all verified strength labels (19)
  • Customizable Surge Arrester for High Voltage Lightning Protection Needs
  • Customizable Surge Arrester for High Voltage Lightning Protection Needs
  • Customizable Surge Arrester for High Voltage Lightning Protection Needs
  • Customizable Surge Arrester for High Voltage Lightning Protection Needs
  • Customizable Surge Arrester for High Voltage Lightning Protection Needs
  • Customizable Surge Arrester for High Voltage Lightning Protection Needs
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Certifications
  • Company Profile
Overview

Basic Info.

Model NO.
YH series
Installation
According to Customer Requirements
Application
AC/DC System/Power Plants/Substation
Size
According to Customer Requirements
Operation Voltage
3 - 36kv
Shape
According to Customer Requirements
Material
ZnO
Certification
ROHS, ISO9001, CCC
Brand
Chbeb
Customizable
OEM/According to Customer Requirements
Voltage Customizable
30kv 33kv 36kv
Transport Package
Pallet
Trademark
CHBEB
Origin
China
HS Code
8535400000
Production Capacity
50000 Pieces/Quarter

Product Description

Product Description

Introducing the Zinc Oxide Arrester from Beierbian Group Co., Ltd - an extraordinary leap forward in lightning protection technology tailored for 10kV power distribution systems. This state-of-the-art device is a testament to modern engineering excellence, highlighted by its advanced zinc oxide valve column and masterfully engineered upper and lower electrodes. Encased in top-tier silicone rubber, it ensures unparalleled reliability and exceptional performance. With its outstanding features, this product redefines industry standards:

  1. This innovative design expertly addresses and resolves the significant sealing challenges that arresters have historically encountered. By cleverly fusing the core and jacket into a singular, compact unit, it removes any potential cavities that could cause internal breathing issues, thereby effectively solving the technical problems associated with moisture ingress within internal components.
  2. Featuring a robust core capable of enduring substantial internal overvoltage, this arrester showcases remarkable aging resistance. It promises extended high-standard performance, delivering unwavering protection that withstands both the tests of time and harsh environmental conditions with superior resilience and reliability.

Through the use of a meticulously crafted valve plate in conjunction with optimized core parameters, this device guarantees exceptional protection. The core is adeptly constructed to mitigate issues such as arc grounding, PT resonance, and a range of operational overvoltages. It operates with unmatched reliability under line voltage conditions and withstands 2.5 to 3 times the power frequency overvoltage. Its voltage endurance significantly surpasses international standards by an impressive 1 to 3 orders of magnitude, providing unrivaled safety and operational durability, establishing a new benchmark for high-performance protection solutions.
Customizable Surge Arrester for High Voltage Lightning Protection Needs

Detailed Photos

Customizable Surge Arrester for High Voltage Lightning Protection Needs

Customizable Surge Arrester for High Voltage Lightning Protection Needs
Customizable Surge Arrester for High Voltage Lightning Protection Needs
Customizable Surge Arrester for High Voltage Lightning Protection Needs
Customizable Surge Arrester for High Voltage Lightning Protection Needs
Customizable Surge Arrester for High Voltage Lightning Protection Needs
Customizable Surge Arrester for High Voltage Lightning Protection Needs

Product Parameters

Main Characteristics Of Jacket Materials And Product Usage Environment:

Item

Unit

Norm

Shore Hardness A

/

60

Tensile Strength

mpa

≥35

Breaking Elongation

%

≥250

Oxygen Index

/

45

Resistivity

Ω.m

≥1×1013

Breakdown Strength

MV/m

≥25

Tracking

kV

4.5

Durability

Not less than 20 years

Working Environment:

This surge arrester is masterfully crafted to deliver outstanding performance, whether placed indoors or outdoors, it seamlessly adapts to diverse locales.

Impressively operational at altitudes reaching a remarkable 3000 meters, it triumphantly conquers high altitudes with ease.

Ingeniously engineered to perform across a wide temperature range from a chilly -40°C to a warm +60°C, it stands resilient against extreme climates, uncompromised.

Meticulously designed to harmonize perfectly with power supply frequencies ranging from a stable 48Hz to a lively 62Hz, ensuring optimal compatibility and performance.

Maintains the power frequency voltage between terminals at an optimal level, guaranteeing enduring and uninterrupted service.

Built to withstand seismic shocks up to 8 degrees, this product guarantees unmatched stability and resilience.

Engineered to resist powerful outdoor winds up to 35 meters per second, offering steadfast reliability against nature's forces.

Note:

For requirements that exceed these standard operational limits, our expert team is ready to provide bespoke solutions tailored precisely to your needs.

Main technical parameters

Model

Nominal Voltage

(rms)

Rated Voltage OArrester

(rms)

Continuous Operating Voltage

(rms)

DC 1mA reference voltage
kV not less than

The residual voltage under nominal discharge current
kV (Crest) not greater than

Steep wave impact residual voltage
kV (Crest) not greater than

2ms square wave flow capacity
A

Operation Place

YH5WS-3.8/17

3

3.8

2.0

7.5

17.0

19.6

100

 

Distribution Type

YH5WS-5/15

3

5

4.0

7.5

15.0

17.3

150

YH5WS-7.6/30

6

7.6

4.0

15.0

15.0

34.5

100

YH5WS-10/30

6

10

8.0

15.0

30.0

34.6

150

YH5WS-12.7/50

10

12.7

10

26.0

50.0

57.5

100

YH5WS-16.5/50

10

16.5

12.7

26.0

50.0

57.5

100

YH5WS-17/50

10

17

13.6

26.0

50.0

57.5

150

YH5WS-17/45

10

17

13.6

25.0

45.0

/

250

YH10WS-17/45

10

17

13.6

25.0

45.0

/

400

YH5WZ-5/13.5

3

5

4.0

7.2

13.5

15.5

200

Power Station Type

YH5WZ-7.6/27

6

7.6

4.0

14.4

27.0

31.0

150

YH5WZ-10/27

6

10

8.0

14.4

27.0

31.0

200

YH5WZ-42/134

35

42

23.4

73

134

154

150

YH5WZ-12.7/45

10

12.7

6.6

24.0

45.0

51.8

150

YH5WZ-16.5/45

10

16.5

13.2

24.0

45.0

51.8

150

YH5WZ-17/45

10

17

13.6

24.0

45.0

51.8

200

YH5WZ-51/134

35

51

40.8

73.0

134

154

400

YH10WZ-17/45

10

17

13.6

24.0

45.0

51.8

200

YH10WZ-51/134

35

51

40.8

73.0

134

154

400

YH5WR-5/13.5

3

5

4.0

7.2

13.5

/

400

Capacitive Type

YH5WR-7.6/27

6

7.6

4.0

13.8

27.0

/

400

YH5WR-10/27

6

10

8.0

14.4

27.0

/

400

YH5WR-12.7/45

10

12.7

6.6

23.0

45.0

/

400

YH5WR 17/45

10

17

13.6

24.0

45.0

/

400

YH5WX-51/134

35

51

40.8

73

134.0

154

400

Line type

YH1.5W-30/80

35

30

24

44

80.0

/

600

Neutral Type

Note: Featuring a durable Polymeric construction, the longevity of this product is significantly enhanced.

Model

Nominal Voltage

(rms)

Rated Voltage OArrester

(rms)

Continuous Operating Voltage

(rms)

DC 1mA Reference Voltage
kV Not Less Than

The Residual Voltage Under Nominal Discharge Current
kV (Crest)
Not Greater Than

Steep Wave Impact Residual Voltage
kV (Crest)
Not Greater Than

2ms Square Wave Flow Capacity
A

Operation Place

Y5WS-5/15

3

5

4.0

7.5

15.0

17.3

150

Distribution Type

Y5WS-7.6/30

6

7.6

4.0

15.0

15.0

34.5

100

Y5WS-10/30

6

10

8.0

15.0

30.0

34.6

150

Y5WS-12.7/50

10

12.7

10

26.0

50.0

57.5

100

Y5WS-16.5/50

10

16.5

12.7

26.0

50.0

57.5

100

Y5WS-17/50

10

17

13.6

26.0

50.0

57.5

150

Y5WZ-5/13.5

3

5

4.0

7.2

13.5

15.5

200

Power Station Type

Y5WZ-7.6/27

6

7.6

4.0

14.4

27.0

31.0

150

Y5WZ-10/27

6

10

8.0

14.4

27.0

31.0

200

Y5WZ-42/134

35

42

23.4

73

134

154

150

Y5WZ-12.7/45

10

12.7

6.6

24.0

45.0

51.8

150

Y5WZ-16.5/45

10

16.5

13.2

24.0

45.0

51.8

150

Y5WZ-17/45

10

17

13.6

24.0

45.0

51.8

200

Y5WZ-51/134

35

51

40.8

73.0

134

154

400

Y5WR-5/13.5

3

5

4.0

7.2

13.5

/

400

Capacitive Type

Y5WR-7.6/27

6

7.6

4.0

13.8

27.0

/

400

Y5WR-10/27

6

10

8.0

14.4

27.0

/

400

Y5WR-12.7/45

10

12.7

6.6

23.0

45.0

/

400

Y5WR-17/45

10

17

13.6

24.0

45.0

/

400

Y1.5W-0.28/1.3

0.22

0.28

0.24

0.6

1.3

/

75

Low Voltage

Y1.5W-0.5/2.6

0.38

0.5

0.24

1.2

2.6

/

75

Note:Porcelain

Model

 

Nominal Voltage
(Valid values)

 

Rated Voltage Of Arrester
(Valid values)

 

The Wave Front

Steepness Of The Shock Discharge

 

DC 1mA Reference Voltage

kV Not Less Than

 

1.2/50 Impulse Discharge Voltage

Not Greater Than

 

Wavefront Impulse

Discharge Voltage

 

kV Not Greater Than

The Residual Voltage Under Nominal Discharge

Current 8/20μs

 

kV Not Greater Than

 

2000μs Square

Wave Flow Capacity

 

4/10μs Impulse

Current Capacity

Y5CS-7.6/27

6

7.6

63

16

35

43.8

27

75

25

Y5CZ-7.6/24

6

7.6

63

16

30

37.5

24

150

40

Y5CS-12.7/45

10

12.7

106

26

50

62.5

45

75

25

Y5CS-12.7/41

10

12.7

106

26

45

56.5

41

200

40

Y5CZ-42/124

35

42.0

343

82

134

168

124

200

40

Note: Incorporates a Porcelain Series Gap specification, lending an air of elegance and refinement.

Installation

(1) Prior to installation, review the nameplate to confirm that the arrester's rated voltage matches the system voltage at the intended installation location.

(2) Offers versatile installation options, allowing for suspension or vertical mounting. For vertical installations, ensure the arrester does not serve as a load-bearing insulator.

(3) Adjust the lead wire length to maximize protective efficiency, reducing stress and enhancing equipment safety.

Test

  • lTo ensure operational reliability, conduct preventive tests every 4-5 years, focusing on measuring U1mA at both ends of the DC 1mA arrester.
  • lBefore installation, verify that the U1mA voltage is no less than 97% of the original factory value, meticulously documenting this information for future reference.
  • lDuring preventive maintenance, confirm that the U1mA voltage consistently remains above 26kV.
  • lNote: Minimize harmonic distortions in the DC power supply during tests to prevent low U1mA readings due to waveform issues.
  • lThe newly introduced 10kV synthetic insulated zinc oxide arrester for power distribution has demonstrated its excellence in stringent lab testing, consistently performing under outdoor line voltage conditions for 15 months. This attests to the jacket's superior quality, the arrester's reliable architecture, and robust core stability. Supported by annual performance data from 2,000 units, it ensures unparalleled protection, extremely low failure rates, and maintenance-free operation throughout its lifecycle.Customizable Surge Arrester for High Voltage Lightning Protection Needs
Certifications

Customizable Surge Arrester for High Voltage Lightning Protection Needs

Company Profile

Customizable Surge Arrester for High Voltage Lightning Protection Needs

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier