Customization: | Available |
---|---|
Breaking Capacity: | 12kv/24kv/40.5kv |
Type: | Current Fuse |
Still deciding? Get samples of $ !
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
(H) RW(F) series outdoor high voltage AC drop fuse, henceforth referred to as 'fuse', is expertly designed for seamless integration into outdoor overhead distribution systems, boasting a rated frequency of 50Hz and rated voltage of 10kV (12/15/35/40.5). Serving as a robust protective component, it diligently safeguards circuits and electrical equipment against overload and short circuit faults within power systems. During normal operation, the fuse remains securely connected in series within the power line, upheld in a tensioned state with the movable joint firmly locked. In the event of a line failure, the resulting fault current activates the fuse's ingenious design, blowing the fuse, releasing the joint, and enabling the rapid drop of the fuse tube to conclusively cut the circuit. This sophisticated mechanism ensures superior safety protection for line maintenance and equipment. An advanced iteration of the fuse, the load type variant, is augmented with elastic contact and an arc extinguishing cover, which together empower it to proficiently open and close the load current within the power system.
The fuse is meticulously engineered to meet the stringent technical standards outlined in GB / T 15166.3 - 2008 High Voltage AC Fuses - Part 3: Injection Fuses, as well as the DL / T 640 - 1997 Outdoor AC High Voltage Drop Tested Fuses and Fuse Links Ordering Technical Conditions, ensuring unparalleled quality and reliability.
Working Environment:
Ambient temperature: -40°C to +40°C; providing outstanding performance across a wide range of climatic conditions.
Relative humidity: daily average should not exceed 95%, with monthly average remaining below 90%; ensuring robust operation even in humid conditions.
The altitude: guaranteed performance for locations not exceeding 3000m.
Outdoor wind speed: capable of withstanding speeds up to an impressive 34 meters/second.
Installation site: must be free from fire, explosion hazard, and chemical corrosive gas, while being well-ventilated for optimal safety and functionality.
Note: Should the specified normal usage conditions be surpassed, users are encouraged to engage in discussions with the company to explore tailored solutions.
Technical parameters
Note: Our company excels in providing products customized to user-specific requirements, ensuring a perfect fit for every application.
Model |
Voltage |
Current |
Rated maximum
breaking current |
1min power frequency dry withstand
voltage |
1min power frequency wet withstand
voltage |
Rated lightning impulse withstand
voltage |
Opening and closing
load current |
XS-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
XS-15/100(200) |
15 |
||||||
PD-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
PD-15/100(200) |
15 |
||||||
(H)RW3-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW3-12/100(200) |
12 |
||||||
(H)RW4-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW4-12/100(200) |
12 |
||||||
(H)RW7-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW7-12/100(200) |
12 |
||||||
(H)RW10-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW10-12/100(200) |
12 |
||||||
(H)RW10-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW10-12F/100(200) |
12 |
||||||
(H)RW11-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
! |
(H)RW11-12/100(200) |
12 |
||||||
(H)RW11-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW11-12F/100(200) |
12 |
||||||
(H)RW12-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
45 |
30 |
105 |
/ |
(H)RW12-12/100(200) |
12 |
||||||
(H)RW12-15/100(200) |
15 |
||||||
(H)PRWG1-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)PRWG1-12F/100(200) |
12 |
||||||
(H)RW33-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW33-15/100(200) |
15 |
||||||
(H)RW5-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)RW10-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)PRWG2-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |