Customization: | Available |
---|---|
Breaking Capacity: | 12kv/24kv/40.5kv |
Type: | Current Fuse |
Still deciding? Get samples of US$ 30/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
(H) RW(F) series outdoor high voltage AC drop fuse (hereinafter referred to as "fuse") is the robust solution for outdoor overhead distribution systems, engineered to operate seamlessly at a rated frequency of 50Hz with a rated voltage spanning 10kV, 12/15/35/40.5. This indispensable protective component safeguards circuits and electrical equipment from overloads and short circuits in power systems. Under normal conditions, the fuse integrates into the power line, remaining taut with a secured movable joint. In the event of a failure, the fault current triggers the fuse to blow, releasing the joint, dropping the fuse tube, and effectively interrupting the circuit. This swift action provides critical safety protection, ensuring the maintenance and integrity of the line and equipment. Enhancing the ordinary type, our load variety incorporates an elastic contact coupled with an arc extinguishing cover, designed to adeptly open and close load currents within the power system.
The fuse is meticulously designed to meet stringent technical standards, including GB / T 15166.3 - 2008 for high voltage AC fuses, Part 3 focused on injection fuses, and DL / T 640 - 1997, governing outdoor AC high voltage drop-tested fuses and essential technical conditions for ordering fuse links.
Working Environment:
Ambient temperature: Ranges from a chilly -40°C to a warm +40°C;
Relative humidity: Daily average should not exceed 95%, while the monthly average should remain below 90%;
The altitude does not exceed 3000 meters;
Outdoor wind speeds should not surpass 34 meters per second;
Installation site: Must be free from fire, explosion hazards, and chemical corrosive gases, ensuring a well-ventilated environment.
Note: If installation conditions exceed the normal parameters, users are encouraged to negotiate with the company for tailored solutions.
Technical parameters
Note: We offer customization to meet specific user requirements, ensuring our products align perfectly with your needs.
Model |
Voltage |
Current |
Rated maximum
breaking current |
1min power frequency dry withstand
voltage |
1min power frequency wet withstand
voltage |
Rated lightning impulse withstand
voltage |
Opening and closing
load current |
XS-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
XS-15/100(200) |
15 |
||||||
PD-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
PD-15/100(200) |
15 |
||||||
(H)RW3-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW3-12/100(200) |
12 |
||||||
(H)RW4-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW4-12/100(200) |
12 |
||||||
(H)RW7-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW7-12/100(200) |
12 |
||||||
(H)RW10-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW10-12/100(200) |
12 |
||||||
(H)RW10-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW10-12F/100(200) |
12 |
||||||
(H)RW11-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
! |
(H)RW11-12/100(200) |
12 |
||||||
(H)RW11-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW11-12F/100(200) |
12 |
||||||
(H)RW12-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
45 |
30 |
105 |
/ |
(H)RW12-12/100(200) |
12 |
||||||
(H)RW12-15/100(200) |
15 |
||||||
(H)PRWG1-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)PRWG1-12F/100(200) |
12 |
||||||
(H)RW33-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW33-15/100(200) |
15 |
||||||
(H)RW5-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)RW10-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)PRWG2-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |