Metal Oxide Surge Protection with Tailored User Requirement Options

Product Details
Customization: Available
Type: Power Source Arrester
Structure: Zinc Oxide Arrester
Still deciding? Get samples of $ !
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

OEM Services
The supplier provides OEM services for popular brands
Quality Assurance
The supplier provides quality assurance
Private Mold
The supplier has private mold
Product Certification
The supplier's products already have relevant certification qualifications, including:
CE
to see all verified strength labels (20)
  • Metal Oxide Surge Protection with Tailored User Requirement Options
  • Metal Oxide Surge Protection with Tailored User Requirement Options
  • Metal Oxide Surge Protection with Tailored User Requirement Options
  • Metal Oxide Surge Protection with Tailored User Requirement Options
  • Metal Oxide Surge Protection with Tailored User Requirement Options
  • Metal Oxide Surge Protection with Tailored User Requirement Options
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Certifications
  • Company Profile
Overview

Basic Info.

Model NO.
YH series
Installation
According to Customer Requirements
Application
AC/DC System/Power Plants/Substation
Size
According to Customer Requirements
Operation Voltage
3 - 36kv
Shape
According to Customer Requirements
Material
ZnO
Certification
ROHS, ISO9001, CCC
Brand
Chbeb
Customizable
OEM/According to Customer Requirements
Voltage Customizable
30kv 33kv 36kv
Transport Package
Pallet
Trademark
CHBEB
Origin
China
HS Code
8535400000
Production Capacity
50000 Pieces/Quarter

Product Description

Product Description

Introducing the Zinc Oxide Arrester from Beierbian Group Co., Ltd. Experience groundbreaking advancement in lightning protection tailored specifically for 10kV power distribution systems. This revolutionary piece of engineering marvel is expertly crafted with a state-of-the-art zinc oxide valve column and meticulously designed upper and lower electrodes. Encased in high-quality silicone rubber, this remarkable assembly ensures unparalleled reliability and top-tier performance. Standing out with its extraordinary features, this product establishes a fresh benchmark in the industry:

  1. This innovative design expertly addresses and overcomes the formidable sealing challenges that have historically plagued arresters. By cleverly integrating the core and jacket into a singular, compact unit, it effectively eliminates any potential cavities, which could otherwise lead to internal breathing issues. This adept architectural approach skillfully resolves the technical concerns of moisture ingress within internal components.
  2. Boasting a robust core designed to endure significant internal overvoltage, this arrester exhibits remarkable aging resistance. It assures extended high-standard performance, providing unwavering protection that withstands the test of time and environmental conditions with exceptional resilience and dependability.

Harnessing a meticulously engineered valve plate paired with optimized core parameters, this device guarantees superior protection. The core is masterfully designed to tackle challenges such as arc grounding, PT resonance, and a wide range of operational overvoltages. It operates with unmatched reliability under line voltage conditions and withstands 2.5 to 3 times the power frequency overvoltage. Its voltage endurance dramatically surpasses international standards by an impressive 1 to 3 orders of magnitude, delivering unparalleled safety and operational longevity, setting an unprecedented standard for high-performance protection solutions.
Metal Oxide Surge Protection with Tailored User Requirement Options

Detailed Photos

Metal Oxide Surge Protection with Tailored User Requirement Options

Metal Oxide Surge Protection with Tailored User Requirement Options
Metal Oxide Surge Protection with Tailored User Requirement Options
Metal Oxide Surge Protection with Tailored User Requirement Options
Metal Oxide Surge Protection with Tailored User Requirement Options
Metal Oxide Surge Protection with Tailored User Requirement Options
Metal Oxide Surge Protection with Tailored User Requirement Options

Product Parameters

Main Characteristics Of Jacket Materials And Product Usage Environment:

Item

Unit

Norm

Shore Hardness A

/

60

Tensile Strength

mpa

≥35

Breaking Elongation

%

≥250

Oxygen Index

/

45

Resistivity

Ω.m

≥1×1013

Breakdown Strength

MV/m

≥25

Tracking

kV

4.5

Durability

Not less than 20 years

Working Environment:

This surge arrester is meticulously designed to provide unparalleled performance across diverse settings, seamlessly adapting to both indoor and outdoor environments with exceptional ease and reliability.

It operates with remarkable efficiency even at impressive altitudes, effortlessly reaching up to 3000 meters, showcasing its robust adaptability.

Ingeniously crafted to function impeccably in a broad temperature range from -40°C to +60°C, this product endures the coldest winters to the hottest summers unflinchingly.

Meticulously engineered to harmonize with power supply frequencies spanning from a steady 48Hz to a dynamic 62Hz, ensuring peak performance and seamless integration.

Engineered to maintain optimal power frequency voltage between terminals, this product ensures enduring, uninterrupted operation and reliability.

Constructed to withstand seismic impacts up to 8 degrees in intensity, this product guarantees exceptional stability and resilience.

Built to resist formidable outdoor winds up to 35 meters per second, this product provides steadfast reliability against the forces of nature.

Note:

For requirements beyond these standard operational specifications, our seasoned team is ready to deliver bespoke solutions tailored to your precise needs.

Main Technical Parameters

Model

Nominal Voltage

(rms)

Rated Voltage OArrester

(rms)

Continuous Operating Voltage

(rms)

DC 1mA reference voltage
kV not less than

The residual voltage under nominal discharge current
kV (Crest) not greater than

Steep wave impact residual voltage
kV (Crest) not greater than

2ms square wave flow capacity
A

Operation Place

YH5WS-3.8/17

3

3.8

2.0

7.5

17.0

19.6

100

 

Distribution Type

YH5WS-5/15

3

5

4.0

7.5

15.0

17.3

150

YH5WS-7.6/30

6

7.6

4.0

15.0

15.0

34.5

100

YH5WS-10/30

6

10

8.0

15.0

30.0

34.6

150

YH5WS-12.7/50

10

12.7

10

26.0

50.0

57.5

100

YH5WS-16.5/50

10

16.5

12.7

26.0

50.0

57.5

100

YH5WS-17/50

10

17

13.6

26.0

50.0

57.5

150

YH5WS-17/45

10

17

13.6

25.0

45.0

/

250

YH10WS-17/45

10

17

13.6

25.0

45.0

/

400

YH5WZ-5/13.5

3

5

4.0

7.2

13.5

15.5

200

Power Station Type

YH5WZ-7.6/27

6

7.6

4.0

14.4

27.0

31.0

150

YH5WZ-10/27

6

10

8.0

14.4

27.0

31.0

200

YH5WZ-42/134

35

42

23.4

73

134

154

150

YH5WZ-12.7/45

10

12.7

6.6

24.0

45.0

51.8

150

YH5WZ-16.5/45

10

16.5

13.2

24.0

45.0

51.8

150

YH5WZ-17/45

10

17

13.6

24.0

45.0

51.8

200

YH5WZ-51/134

35

51

40.8

73.0

134

154

400

YH10WZ-17/45

10

17

13.6

24.0

45.0

51.8

200

YH10WZ-51/134

35

51

40.8

73.0

134

154

400

YH5WR-5/13.5

3

5

4.0

7.2

13.5

/

400

Capacitive Type

YH5WR-7.6/27

6

7.6

4.0

13.8

27.0

/

400

YH5WR-10/27

6

10

8.0

14.4

27.0

/

400

YH5WR-12.7/45

10

12.7

6.6

23.0

45.0

/

400

YH5WR 17/45

10

17

13.6

24.0

45.0

/

400

YH5WX-51/134

35

51

40.8

73

134.0

154

400

Line type

YH1.5W-30/80

35

30

24

44

80.0

/

600

Neutral Type

Note: With its robust Polymeric construction, the product's durability is significantly elevated, ensuring long-lasting performance.

Model

Nominal Voltage

(rms)

Rated Voltage OArrester

(rms)

Continuous Operating Voltage

(rms)

DC 1mA Reference Voltage
kV Not Less Than

The Residual Voltage Under Nominal Discharge Current
kV (Crest)
Not Greater Than

Steep Wave Impact Residual Voltage
kV (Crest)
Not Greater Than

2ms Square Wave Flow Capacity
A

Operation Place

Y5WS-5/15

3

5

4.0

7.5

15.0

17.3

150

Distribution Type

Y5WS-7.6/30

6

7.6

4.0

15.0

15.0

34.5

100

Y5WS-10/30

6

10

8.0

15.0

30.0

34.6

150

Y5WS-12.7/50

10

12.7

10

26.0

50.0

57.5

100

Y5WS-16.5/50

10

16.5

12.7

26.0

50.0

57.5

100

Y5WS-17/50

10

17

13.6

26.0

50.0

57.5

150

Y5WZ-5/13.5

3

5

4.0

7.2

13.5

15.5

200

Power Station Type

Y5WZ-7.6/27

6

7.6

4.0

14.4

27.0

31.0

150

Y5WZ-10/27

6

10

8.0

14.4

27.0

31.0

200

Y5WZ-42/134

35

42

23.4

73

134

154

150

Y5WZ-12.7/45

10

12.7

6.6

24.0

45.0

51.8

150

Y5WZ-16.5/45

10

16.5

13.2

24.0

45.0

51.8

150

Y5WZ-17/45

10

17

13.6

24.0

45.0

51.8

200

Y5WZ-51/134

35

51

40.8

73.0

134

154

400

Y5WR-5/13.5

3

5

4.0

7.2

13.5

/

400

Capacitive Type

Y5WR-7.6/27

6

7.6

4.0

13.8

27.0

/

400

Y5WR-10/27

6

10

8.0

14.4

27.0

/

400

Y5WR-12.7/45

10

12.7

6.6

23.0

45.0

/

400

Y5WR-17/45

10

17

13.6

24.0

45.0

/

400

Y1.5W-0.28/1.3

0.22

0.28

0.24

0.6

1.3

/

75

Low Voltage

Y1.5W-0.5/2.6

0.38

0.5

0.24

1.2

2.6

/

75

Note:Porcelain

Model

 

Nominal Voltage
(Valid values)

 

Rated Voltage Of Arrester
(Valid values)

 

The Wave Front

Steepness Of The Shock Discharge

 

DC 1mA Reference Voltage

kV Not Less Than

 

1.2/50 Impulse Discharge Voltage

Not Greater Than

 

Wavefront Impulse

Discharge Voltage

 

kV Not Greater Than

The Residual Voltage Under Nominal Discharge

Current 8/20μs

 

kV Not Greater Than

 

2000μs Square

Wave Flow Capacity

 

4/10μs Impulse

Current Capacity

Y5CS-7.6/27

6

7.6

63

16

35

43.8

27

75

25

Y5CZ-7.6/24

6

7.6

63

16

30

37.5

24

150

40

Y5CS-12.7/45

10

12.7

106

26

50

62.5

45

75

25

Y5CS-12.7/41

10

12.7

106

26

45

56.5

41

200

40

Y5CZ-42/124

35

42.0

343

82

134

168

124

200

40

Note: Features a Porcelain Series Gap specification, imparting an aura of elegance and sophistication to the product.

Installation

(1) Before installation, carefully examine the nameplate to confirm the arrester's rated voltage matches the system voltage at the intended installation site.

(2) Provides flexible installation options, allowing for suspension or vertical mounting. For vertical setups, ensure the arrester is not used as a load-bearing insulator to maintain its integrity.

(3) Adjust the lead wire length for optimal protection efficiency, minimizing stress and maximizing safety for all equipment.

Test

  • To ensure operational reliability, conduct preventive tests every 4-5 years, focusing on measuring U1mA at both ends of the DC 1mA arrester for accuracy.
  • Before installation, verify that the U1mA voltage is no less than 97% of the original factory value, and diligently record this data for future reference and consistency.
  • During preventive maintenance, ensure the U1mA voltage remains consistently above 26kV, maintaining optimal performance and reliability.
  • Note: Minimize harmonic distortions in the DC power supply during tests to avoid incorrect low U1mA readings caused by faulty waveforms.
  • The newly introduced 10kV synthetic insulated zinc oxide arrester for power distribution has demonstrated exceptional reliability in stringent laboratory tests. It has continuously performed under outdoor line voltage conditions for 15 months, underscoring the jacket's superior quality, the arrester's trustworthy structure, and robust core stability. Annual performance records from 2,000 units attest to its unmatched protection capabilities, exceptionally low failure rates, and maintenance-free operation throughout its lifecycle, ensuring peace of mind for all users.Metal Oxide Surge Protection with Tailored User Requirement Options
Certifications

Metal Oxide Surge Protection with Tailored User Requirement Options

Company Profile

Metal Oxide Surge Protection with Tailored User Requirement Options

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier