(H) RW(F) series outdoor high voltage AC drop fuse (hereinafter referred to as "fuse") is a high-performance safeguard designed specifically for outdoor overhead distribution systems. Engineered for reliability, it operates seamlessly at a rated frequency of 50Hz and rated voltage ranging from 10kV to 40.5kV. This indispensable component serves as a protective element for circuits or electrical equipment, safeguarding against overloads or short circuit faults within power systems. Under normal conditions, the fuse integrates into power lines, maintaining a tensioned state with a securely locked movable joint. In the event of a fault, the fault current activates the fuse, releasing the joint and swiftly dropping the fuse tube to sever the circuit, ensuring robust safety protection for line and equipment maintenance. Enhanced with elastic contact and an arc extinguishing cover, the load type fuse excels at opening and closing load currents within power systems, elevating safety and operational efficiency.
The fuse is meticulously crafted to meet rigorous technical standards, including GB / T 15166.3 - 2008 high voltage AC fuses - Part 3: injection fuses, and DL / T 640 - 1997 outdoor AC high voltage drop tested fuses and fuse links ordering technical conditions, ensuring exceptional quality and performance.
Working Environment:
Ambient temperature: -40°C to +40°C; providing reliable operation across extreme temperature ranges.
Relative humidity: Ensures optimal performance with a daily average not exceeding 95% and a monthly average not exceeding 90%.
The altitude is reliably supported up to 3000 meters; ensuring adaptability across various terrains.
Designed to withstand outdoor wind speeds of up to 34 meters/second; providing robust durability against harsh weather conditions.
Installation site: Free from fire, explosion hazards, and chemical corrosive gases, while ensuring a well-ventilated environment for optimal performance.
Note: Should operational conditions exceed the specified norms, a negotiation with the company is welcomed to accommodate specific requirements.
Technical parameters ensure precise and reliable operation.
Note: Our company is equipped to supply customized products tailored to user specifications.
Model |
Voltage |
Current |
Rated maximum
breaking current |
1min power frequency dry withstand
voltage |
1min power frequency wet withstand
voltage |
Rated lightning impulse withstand
voltage |
Opening and closing
load current |
XS-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
XS-15/100(200) |
15 |
||||||
PD-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
PD-15/100(200) |
15 |
||||||
(H)RW3-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW3-12/100(200) |
12 |
||||||
(H)RW4-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW4-12/100(200) |
12 |
||||||
(H)RW7-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW7-12/100(200) |
12 |
||||||
(H)RW10-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW10-12/100(200) |
12 |
||||||
(H)RW10-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW10-12F/100(200) |
12 |
||||||
(H)RW11-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
! |
(H)RW11-12/100(200) |
12 |
||||||
(H)RW11-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW11-12F/100(200) |
12 |
||||||
(H)RW12-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
45 |
30 |
105 |
/ |
(H)RW12-12/100(200) |
12 |
||||||
(H)RW12-15/100(200) |
15 |
||||||
(H)PRWG1-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)PRWG1-12F/100(200) |
12 |
||||||
(H)RW33-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW33-15/100(200) |
15 |
||||||
(H)RW5-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)RW10-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)PRWG2-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |