Customization: | Available |
---|---|
Breaking Capacity: | 12kv/24kv/40.5kv |
Type: | Current Fuse |
Still deciding? Get samples of US$ 30/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
(H) RW(F) series outdoor high voltage AC drop fuse, affectionately known as the 'fuse', is the quintessential choice for high-stakes protection in outdoor overhead distribution systems. Designed for a rated frequency of 50Hz and boasting a rated voltage of 10kV (12/15/35/40.5), this fuse stands guard against the adversities of overloads and short circuit faults that threaten your power system's integrity. During regular operation, it seamlessly integrates into the power line, maintaining a vigilant tension while the movable joint remains securely locked. Upon sensing a fault, the fault current fearlessly takes action, initiating the fuse to blow and promptly releasing the movable joint. The fuse tube swiftly descends, courageously cutting off the circuit to ensure the safety and protection of your equipment and line maintenance. This advanced load type fuse comes enhanced with an elastic contact and a specially designed arc extinguishing cover, specifically engineered to open and close the load current within the power system with unparalleled precision.
Our fuses adhere to distinguished technical standards, including GB / T 15166.3 - 2008 for high voltage AC fuses - Part 3: injection fuses, and DL / T 640 - 1997 for outdoor AC high voltage drop tested fuses and fuse links ordering technical conditions, ensuring reliability and excellence.
Working Environment:
Immerse your operations in an ambient temperature ranging from a crisp -40°C to a balmy +40°C;
Relish in a relative humidity environment where the daily average remains comfortably below 95%, and the monthly average does not exceed 90%;
Experience performance at altitudes that do not surpass 3000 meters;
Remain unfazed by outdoor wind speeds that do not exceed the robust limit of 34 meters per second;
Install in locations free from fire hazards, explosions, and chemical corrosive gases, all while enjoying a well-ventilated ambiance.
Note: Should your requirements transcend these normal conditions, feel free to engage in a collaborative dialogue with us for tailored solutions.
Technical parameters
Note: Our company is poised to deliver products meticulously customized to match your specific requirements.
Model |
Voltage |
Current |
Rated maximum
breaking current |
1min power frequency dry withstand
voltage |
1min power frequency wet withstand
voltage |
Rated lightning impulse withstand
voltage |
Opening and closing
load current |
XS-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
XS-15/100(200) |
15 |
||||||
PD-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
PD-15/100(200) |
15 |
||||||
(H)RW3-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW3-12/100(200) |
12 |
||||||
(H)RW4-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW4-12/100(200) |
12 |
||||||
(H)RW7-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW7-12/100(200) |
12 |
||||||
(H)RW10-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW10-12/100(200) |
12 |
||||||
(H)RW10-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW10-12F/100(200) |
12 |
||||||
(H)RW11-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
! |
(H)RW11-12/100(200) |
12 |
||||||
(H)RW11-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW11-12F/100(200) |
12 |
||||||
(H)RW12-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
45 |
30 |
105 |
/ |
(H)RW12-12/100(200) |
12 |
||||||
(H)RW12-15/100(200) |
15 |
||||||
(H)PRWG1-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)PRWG1-12F/100(200) |
12 |
||||||
(H)RW33-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW33-15/100(200) |
15 |
||||||
(H)RW5-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)RW10-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)PRWG2-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |