Metal Oxide Surge Protection with Tailored Voltage and User Needs

Product Details
Customization: Available
Type: Power Source Arrester
Structure: Zinc Oxide Arrester
Still deciding? Get samples of US$ 35/Piece
Request Sample
Manufacturer/Factory

360° Virtual Tour

Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

OEM Services
The supplier provides OEM services for popular brands
Quality Assurance
The supplier provides quality assurance
Private Mold
The supplier has private mold
Product Certification
The supplier's products already have relevant certification qualifications, including:
CE
to see all verified strength labels (19)
  • Metal Oxide Surge Protection with Tailored Voltage and User Needs
  • Metal Oxide Surge Protection with Tailored Voltage and User Needs
  • Metal Oxide Surge Protection with Tailored Voltage and User Needs
  • Metal Oxide Surge Protection with Tailored Voltage and User Needs
  • Metal Oxide Surge Protection with Tailored Voltage and User Needs
  • Metal Oxide Surge Protection with Tailored Voltage and User Needs
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Certifications
  • Company Profile
Overview

Basic Info.

Model NO.
YH series
Installation
According to Customer Requirements
Application
AC/DC System/Power Plants/Substation
Size
According to Customer Requirements
Operation Voltage
3 - 36kv
Shape
According to Customer Requirements
Material
ZnO
Certification
ROHS, ISO9001, CCC
Brand
Chbeb
Customizable
OEM/According to Customer Requirements
Voltage Customizable
30kv 33kv 36kv
Transport Package
Pallet
Trademark
CHBEB
Origin
China
HS Code
8535400000
Production Capacity
50000 Pieces/Quarter

Product Description

Product Description

Introducing the Zinc Oxide Arrester from Beierbian Group Co., Ltd - a groundbreaking innovation in lightning protection for 10kV power distribution systems. This revolutionary device is a marvel of modern engineering, featuring a cutting-edge zinc oxide valve column and exquisitely crafted upper and lower electrodes. The entire assembly is encased in premium silicone rubber, providing unmatched reliability and performance. Boasting exceptional features, this product sets a new benchmark in the industry:

  1. This pioneering design astutely tackles and resolves the formidable sealing challenges historically faced by arresters. By ingeniously integrating the core and jacket into a unified, compact unit, it eliminates any potential cavities that could lead to internal breathing complications, thereby masterfully addressing the technical issues of moisture ingress within internal components.
  2. Equipped with a powerful core capable of withstanding significant internal overvoltage, this arrester demonstrates outstanding aging resistance. It guarantees prolonged high-standard performance, offering steadfast protection that endures the rigors of time and environmental conditions with exceptional resilience and dependability.

Utilizing a meticulously engineered valve plate combined with optimized core parameters, this device ensures superior protection. The core is adeptly designed to counteract challenges such as arc grounding, PT resonance, and a spectrum of operational overvoltages. It operates with unrivaled reliability under line voltage conditions, while also withstanding 2.5 to 3 times the power frequency overvoltage. Its voltage endurance far exceeds international standards by a remarkable 1 to 3 orders of magnitude, delivering unmatched safety and operational longevity, setting a new standard for high-performance protection solutions.
Metal Oxide Surge Protection with Tailored Voltage and User Needs

Detailed Photos

Metal Oxide Surge Protection with Tailored Voltage and User Needs

Metal Oxide Surge Protection with Tailored Voltage and User Needs
Metal Oxide Surge Protection with Tailored Voltage and User Needs
Metal Oxide Surge Protection with Tailored Voltage and User Needs
Metal Oxide Surge Protection with Tailored Voltage and User Needs
Metal Oxide Surge Protection with Tailored Voltage and User Needs
Metal Oxide Surge Protection with Tailored Voltage and User Needs

Product Parameters

Main Characteristics Of Jacket Materials And Product Usage Environment:

Item

Unit

Norm

Shore Hardness A

/

60

Tensile Strength

mpa

≥35

Breaking Elongation

%

≥250

Oxygen Index

/

45

Resistivity

Ω.m

≥1×1013

Breakdown Strength

MV/m

≥25

Tracking

kV

4.5

Durability

Not less than 20 years

Working Environment:

Introducing a surge arrester of exceptional design, engineered to deliver superior performance in any setting. Whether indoors or outdoors, it seamlessly adapts to your demands with unwavering resilience.

Capably operating even at breathtaking altitudes, this product conquers heights of up to 3000 meters effortlessly, ensuring dependable functionality in elevated regions.

Meticulously crafted to operate flawlessly across a wide temperature range from -40°C to +60°C, this product is built to withstand extreme cold and heat without compromising performance.

Designed with precision to match power supply frequencies from 48Hz to 62Hz, ensuring seamless compatibility and adaptability to different systems.

Guarantees the power frequency voltage between terminals remains perfectly optimized, ensuring consistent, uninterrupted operation for long-lasting performance.

Engineered to withstand seismic shocks up to an impressive 8 degrees, this product delivers remarkable stability and reliability, assuring peace of mind during earthquakes.

Constructed to endure fierce outdoor winds up to 35 meters per second, it offers unwavering dependability, standing strong against the forces of nature.

Note:

Should your requirements surpass these standard operational limits, our expert team stands ready to provide bespoke solutions perfectly tailored to your specific needs.

Main technical parameters

Model

Nominal Voltage

(rms)

Rated Voltage OArrester

(rms)

Continuous Operating Voltage

(rms)

DC 1mA reference voltage
kV not less than

The residual voltage under nominal discharge current
kV (Crest) not greater than

Steep wave impact residual voltage
kV (Crest) not greater than

2ms square wave flow capacity
A

Operation Place

YH5WS-3.8/17

3

3.8

2.0

7.5

17.0

19.6

100

 

Distribution Type

YH5WS-5/15

3

5

4.0

7.5

15.0

17.3

150

YH5WS-7.6/30

6

7.6

4.0

15.0

15.0

34.5

100

YH5WS-10/30

6

10

8.0

15.0

30.0

34.6

150

YH5WS-12.7/50

10

12.7

10

26.0

50.0

57.5

100

YH5WS-16.5/50

10

16.5

12.7

26.0

50.0

57.5

100

YH5WS-17/50

10

17

13.6

26.0

50.0

57.5

150

YH5WS-17/45

10

17

13.6

25.0

45.0

/

250

YH10WS-17/45

10

17

13.6

25.0

45.0

/

400

YH5WZ-5/13.5

3

5

4.0

7.2

13.5

15.5

200

Power Station Type

YH5WZ-7.6/27

6

7.6

4.0

14.4

27.0

31.0

150

YH5WZ-10/27

6

10

8.0

14.4

27.0

31.0

200

YH5WZ-42/134

35

42

23.4

73

134

154

150

YH5WZ-12.7/45

10

12.7

6.6

24.0

45.0

51.8

150

YH5WZ-16.5/45

10

16.5

13.2

24.0

45.0

51.8

150

YH5WZ-17/45

10

17

13.6

24.0

45.0

51.8

200

YH5WZ-51/134

35

51

40.8

73.0

134

154

400

YH10WZ-17/45

10

17

13.6

24.0

45.0

51.8

200

YH10WZ-51/134

35

51

40.8

73.0

134

154

400

YH5WR-5/13.5

3

5

4.0

7.2

13.5

/

400

Capacitive Type

YH5WR-7.6/27

6

7.6

4.0

13.8

27.0

/

400

YH5WR-10/27

6

10

8.0

14.4

27.0

/

400

YH5WR-12.7/45

10

12.7

6.6

23.0

45.0

/

400

YH5WR 17/45

10

17

13.6

24.0

45.0

/

400

YH5WX-51/134

35

51

40.8

73

134.0

154

400

Line type

YH1.5W-30/80

35

30

24

44

80.0

/

600

Neutral Type

Note: Built with a sturdy Polymeric construction, this product's durability is significantly improved, promising extended service life.

Model

Nominal Voltage

(rms)

Rated Voltage OArrester

(rms)

Continuous Operating Voltage

(rms)

DC 1mA Reference Voltage
kV Not Less Than

The Residual Voltage Under Nominal Discharge Current
kV (Crest)
Not Greater Than

Steep Wave Impact Residual Voltage
kV (Crest)
Not Greater Than

2ms Square Wave Flow Capacity
A

Operation Place

Y5WS-5/15

3

5

4.0

7.5

15.0

17.3

150

Distribution Type

Y5WS-7.6/30

6

7.6

4.0

15.0

15.0

34.5

100

Y5WS-10/30

6

10

8.0

15.0

30.0

34.6

150

Y5WS-12.7/50

10

12.7

10

26.0

50.0

57.5

100

Y5WS-16.5/50

10

16.5

12.7

26.0

50.0

57.5

100

Y5WS-17/50

10

17

13.6

26.0

50.0

57.5

150

Y5WZ-5/13.5

3

5

4.0

7.2

13.5

15.5

200

Power Station Type

Y5WZ-7.6/27

6

7.6

4.0

14.4

27.0

31.0

150

Y5WZ-10/27

6

10

8.0

14.4

27.0

31.0

200

Y5WZ-42/134

35

42

23.4

73

134

154

150

Y5WZ-12.7/45

10

12.7

6.6

24.0

45.0

51.8

150

Y5WZ-16.5/45

10

16.5

13.2

24.0

45.0

51.8

150

Y5WZ-17/45

10

17

13.6

24.0

45.0

51.8

200

Y5WZ-51/134

35

51

40.8

73.0

134

154

400

Y5WR-5/13.5

3

5

4.0

7.2

13.5

/

400

Capacitive Type

Y5WR-7.6/27

6

7.6

4.0

13.8

27.0

/

400

Y5WR-10/27

6

10

8.0

14.4

27.0

/

400

Y5WR-12.7/45

10

12.7

6.6

23.0

45.0

/

400

Y5WR-17/45

10

17

13.6

24.0

45.0

/

400

Y1.5W-0.28/1.3

0.22

0.28

0.24

0.6

1.3

/

75

Low Voltage

Y1.5W-0.5/2.6

0.38

0.5

0.24

1.2

2.6

/

75

Note:Porcelain

Model

 

Nominal Voltage
(Valid values)

 

Rated Voltage Of Arrester
(Valid values)

 

The Wave Front

Steepness Of The Shock Discharge

 

DC 1mA Reference Voltage

kV Not Less Than

 

1.2/50 Impulse Discharge Voltage

Not Greater Than

 

Wavefront Impulse

Discharge Voltage

 

kV Not Greater Than

The Residual Voltage Under Nominal Discharge

Current 8/20μs

 

kV Not Greater Than

 

2000μs Square

Wave Flow Capacity

 

4/10μs Impulse

Current Capacity

Y5CS-7.6/27

6

7.6

63

16

35

43.8

27

75

25

Y5CZ-7.6/24

6

7.6

63

16

30

37.5

24

150

40

Y5CS-12.7/45

10

12.7

106

26

50

62.5

45

75

25

Y5CS-12.7/41

10

12.7

106

26

45

56.5

41

200

40

Y5CZ-42/124

35

42.0

343

82

134

168

124

200

40

Note: Incorporates a Porcelain Series Gap specification, lending an air of distinction and refinement to the design.

Installation

(1) Before installation, verify the nameplate details to ensure the arrester's rated voltage matches the system voltage at the intended installation site.

(2) Offers versatile installation options, including suspension or vertical mounting. In vertical configurations, ensure the arrester isn't used as a load-bearing insulator.

(3) Optimize lead wire length for enhanced protection efficacy, minimizing stress and guaranteeing maximum safety of your equipment.

Test

  • l To enhance operational trustworthiness, perform preventive tests every 4-5 years, focusing on measuring U1mA at both ends of the DC 1mA arrester.
  • l Before installation, confirm that the U1mA voltage is not less than 97% of the original factory value, and meticulously log this data for future reference.
  • l During preventive maintenance, ensure that the U1mA voltage consistently remains above 26kV to maintain optimal operation.
  • l Note: Minimize harmonic distortions in the DC power supply during tests to prevent low U1mA readings caused by incorrect waveforms.
  • l The newly launched 10kV synthetic insulated zinc oxide arrester for power distribution has proven its reliability in comprehensive lab testing, consistently performing under outdoor line voltage conditions for 15 months. This is a testament to the superior quality of the jacket, the arrester's reliable structure, and robust core stability. With annual performance data from 2,000 units, it guarantees unparalleled protection, exceptionally low failure rates, and maintenance-free operation throughout its entire lifecycle.Metal Oxide Surge Protection with Tailored Voltage and User Needs
Certifications

Metal Oxide Surge Protection with Tailored Voltage and User Needs

Company Profile

Metal Oxide Surge Protection with Tailored Voltage and User Needs

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier