High Voltage AC Disconnector – Outdoor Isolation Switch for Power Distribution and Safety

Product Details
Customization: Available
Type: 10kv/12kv/15kv
Structure: According to Customer Requirements
Still deciding? Get samples of $ !
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

OEM Services
The supplier provides OEM services for popular brands
Quality Assurance
The supplier provides quality assurance
Private Mold
The supplier has private mold
Product Certification
The supplier's products already have relevant certification qualifications, including:
CE
to see all verified strength labels (20)
  • High Voltage AC Disconnector – Outdoor Isolation Switch for Power Distribution and Safety
  • High Voltage AC Disconnector – Outdoor Isolation Switch for Power Distribution and Safety
  • High Voltage AC Disconnector – Outdoor Isolation Switch for Power Distribution and Safety
  • High Voltage AC Disconnector – Outdoor Isolation Switch for Power Distribution and Safety
  • High Voltage AC Disconnector – Outdoor Isolation Switch for Power Distribution and Safety
  • High Voltage AC Disconnector – Outdoor Isolation Switch for Power Distribution and Safety
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Certifications
Overview

Basic Info.

Model NO.
(H)GWBEB
Installation
Outdoor High-voltage
Operation
Manual/Electric/Pneumatic/Hydraulic
Grounding Mode
According to Customer Requirements
Movement Mode
According to Customer Requirements
Number of Poles
According to Customer Requirements
Grounding
According to Customer Requirements
Series
Two
Run
According to Customer Requirements
Switching Mode
According to Customer Requirements
Common Model
Gw9
Structure of Operating
According to Customer Requirements
Certification
ISO, RoHS, CE
Brand
Chbeb
Customizable
OEM/According to Customer Requirements
Transport Package
Standard Shipping Packing
Specification
45*55*38mm
Trademark
CHBEB
Origin
China
HS Code
853530900
Production Capacity
5000 PCS/Quarter

Packaging & Delivery

Package Size
45.00cm * 55.00cm * 38.00cm
Package Gross Weight
20.000kg

Product Description

High Voltage AC Disconnector – Outdoor Isolation Switch for Power Distribution and Safety
Product Description

Introducing the exceptional (H)GWBEB type outdoor high-voltage isolation switch, also known as the isolation disconnect switch. Crafted for efficiency, it is designed to operate seamlessly on 10(12, 15, 24)kV high voltage power transmission and distribution lines. This masterfully engineered switch excels in opening and closing single-phase or three-phase circuits without engaging a load, while voltage is present, ensuring reliable performance.

Engineered for precision, this switch is tailored for single-phase applications within three-phase line systems, boasting a simple yet robust structure. It stands out for its cost-effectiveness and user-friendly operation. With a range of available rated currents from 200 to 1250 amps, these switches comprise a sturdy base, post insulators, conductive parts, and a mechanical section. The innovative gate knife structure ensures efficient circuit operation, featuring two conductive blades per phase with robust external compression springs. Adjusting the spring height allows for optimal contact pressure. An insulated hook stick provides safe operation for opening and closing, complemented by a self-locking device for added security.

Working Environment:

Designed to perform flawlessly at altitudes not exceeding 1000 meters;

Withstands ambient temperatures up to a maximum of +40°C or a minimum of -30°C;

Operational efficiency remains unaffected by outdoor wind speeds up to 35 meters per second;

Built to endure seismic intensities not exceeding 8 degrees, ensuring stability in locations without frequent severe vibrations.

The installation site must be free from gases, chemical deposits, salt mist, dust, dirt, or other explosive or corrosive mediums that might adversely affect the switch's insulation and conductivity.

Note:

IF THE ABOVE NORMAL USE CONDITIONS ARE EXCEEDED, USERS ARE ENCOURAGED TO NEGOTIATE WITH THE COMPANY FOR OPTIMAL SOLUTIONS.

 

Installation, Use and Adjustment

Pre-installation work

  1. Thoroughly remove all dust and dirt from the parts and meticulously clean the surface of the insulating porcelain bottle to ensure pristine conditions.
  2. Carefully scrub the wiring surface of the ground screw for maximum conductivity.
  3. Apply a protective layer of industrial Vaseline to all rotating parts and contact areas to ensure smooth operation.
  4. Inspect the contact surface and adjust the compression spring height to maintain the contact pressure in accordance with Table II for optimal performance.
  5. This switch is exclusively designed for hoisting use and is intended to be used in tandem with the transformer on the line for maximum efficacy.
  6. The switch's rated current is between 200-400 ampere hours, typically utilizing three mounting holes, while 600-1000A configurations also employ three mounting holes.

Annual maintenance checklist for the switch includes:
Meticulously remove dirt from conductive parts, contact surfaces, and the insulating porcelain bottles to ensure optimal functioning.

Carefully inspect all components for potential damage, with particular emphasis on checking the insulating porcelain bottles for any damage or cracks.

Verify that the contact surfaces of the conductive parts maintain their integrity and functionality.


High Voltage AC Disconnector – Outdoor Isolation Switch for Power Distribution and Safety

Detailed Photos

 

High Voltage AC Disconnector – Outdoor Isolation Switch for Power Distribution and Safety
High Voltage AC Disconnector – Outdoor Isolation Switch for Power Distribution and Safety
High Voltage AC Disconnector – Outdoor Isolation Switch for Power Distribution and Safety
High Voltage AC Disconnector – Outdoor Isolation Switch for Power Distribution and Safety


High Voltage AC Disconnector – Outdoor Isolation Switch for Power Distribution and Safety
High Voltage AC Disconnector – Outdoor Isolation Switch for Power Distribution and Safety

High Voltage AC Disconnector – Outdoor Isolation Switch for Power Distribution and Safety
High Voltage AC Disconnector – Outdoor Isolation Switch for Power Distribution and Safety
High Voltage AC Disconnector – Outdoor Isolation Switch for Power Distribution and Safety
High Voltage AC Disconnector – Outdoor Isolation Switch for Power Distribution and Safety
High Voltage AC Disconnector – Outdoor Isolation Switch for Power Distribution and Safety
High Voltage AC Disconnector – Outdoor Isolation Switch for Power Distribution and Safety
High Voltage AC Disconnector – Outdoor Isolation Switch for Power Distribution and Safety
High Voltage AC Disconnector – Outdoor Isolation Switch for Power Distribution and Safety
High Voltage AC Disconnector – Outdoor Isolation Switch for Power Distribution and Safety
High Voltage AC Disconnector – Outdoor Isolation Switch for Power Distribution and Safety
High Voltage AC Disconnector – Outdoor Isolation Switch for Power Distribution and Safety
High Voltage AC Disconnector – Outdoor Isolation Switch for Power Distribution and Safety

 

Product Parameters

The main technical parameters

Table I

Model

Rated voltage
kV

 

Rated current
A

kA

 

10 seconds thermal stable current
kA

peak

Valid values

 

(H)GW

 

10

12

15

200

5

9

5

400

21

15

10

600

35

25

14

630

35

25

14

800

35

25

14

1000

50

35

20

Contact force parameters

Table II

Model

Rated current(A)

contact pressure(kgf)

(H)GW

5

9

21

15

35

25

35

25

35

25

50

35

Certifications

High Voltage AC Disconnector – Outdoor Isolation Switch for Power Distribution and SafetyHigh Voltage AC Disconnector – Outdoor Isolation Switch for Power Distribution and Safety

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now