(H) RW(F) series outdoor high voltage AC drop fuse, hereinafter referred to as "fuse," is a state-of-the-art protective solution designed for outdoor overhead distribution systems with a rated frequency of 50Hz and a rated voltage of 10kV (12/15/35/40.5). This essential component protects circuits or electrical equipment from overload or short circuit faults in power systems. During normal operation, the fuse, placed in series within the power line, remains tensioned and securely locked. In the event of a line failure, the fault current detonates the fuse to sever, releasing the movable joint, swiftly dropping the fuse tube to disconnect the circuit. This mechanism ensures robust safety protection for line and equipment maintenance. Enhanced with elastic contact and an arc extinguishing cover, the load type fuse allows effective opening and closing of load currents within the power system.
The fuse is meticulously crafted to adhere to rigorous technical standards, including GB / T 15166.3 - 2008 high voltage AC fuses - Part 3: injection fuses, and DL / T 640 - 1997 outdoor AC high voltage drop tested fuses and fuse links ordering technical conditions, ensuring unmatched reliability and excellence.
Working Environment:
Ambient temperature: -40°C to +40°C;
Relative humidity: Daily average not exceeding 95%, and monthly average not exceeding 90%;
The installation site should not surpass an altitude of 3000 meters;
Outdoor wind speed should remain below 34 meters/second;
Installation site: Must be free from fire, explosion hazards, corrosive chemicals, and should be a well-ventilated area.
Note: Should conditions exceed the above parameters, users are encouraged to consult with the company for tailored solutions.
Technical parameters
Note: Our company is committed to delivering products customized to user specifications.
Model |
Voltage |
Current |
Rated maximum
breaking current |
1min power frequency dry withstand
voltage |
1min power frequency wet withstand
voltage |
Rated lightning impulse withstand
voltage |
Opening and closing
load current |
XS-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
XS-15/100(200) |
15 |
||||||
PD-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
PD-15/100(200) |
15 |
||||||
(H)RW3-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW3-12/100(200) |
12 |
||||||
(H)RW4-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW4-12/100(200) |
12 |
||||||
(H)RW7-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW7-12/100(200) |
12 |
||||||
(H)RW10-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW10-12/100(200) |
12 |
||||||
(H)RW10-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW10-12F/100(200) |
12 |
||||||
(H)RW11-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
! |
(H)RW11-12/100(200) |
12 |
||||||
(H)RW11-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW11-12F/100(200) |
12 |
||||||
(H)RW12-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
45 |
30 |
105 |
/ |
(H)RW12-12/100(200) |
12 |
||||||
(H)RW12-15/100(200) |
15 |
||||||
(H)PRWG1-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)PRWG1-12F/100(200) |
12 |
||||||
(H)RW33-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW33-15/100(200) |
15 |
||||||
(H)RW5-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)RW10-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)PRWG2-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |