Advanced Load Break Disconnect Switch for High Voltage Outdoor Applications

Product Details
Customization: Available
Type: 10kv/12kv/15kv
Structure: According to Customer Requirements
Still deciding? Get samples of US$ 140/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

OEM Services
The supplier provides OEM services for popular brands
Quality Assurance
The supplier provides quality assurance
Private Mold
The supplier has private mold
Product Certification
The supplier's products already have relevant certification qualifications, including:
CE
to see all verified strength labels (20)
  • Advanced Load Break Disconnect Switch for High Voltage Outdoor Applications
  • Advanced Load Break Disconnect Switch for High Voltage Outdoor Applications
  • Advanced Load Break Disconnect Switch for High Voltage Outdoor Applications
  • Advanced Load Break Disconnect Switch for High Voltage Outdoor Applications
  • Advanced Load Break Disconnect Switch for High Voltage Outdoor Applications
  • Advanced Load Break Disconnect Switch for High Voltage Outdoor Applications
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Certifications
Overview

Basic Info.

Model NO.
(H)GWBEB
Installation
Outdoor High-voltage
Operation
Manual/Electric/Pneumatic/Hydraulic
Grounding Mode
According to Customer Requirements
Movement Mode
According to Customer Requirements
Number of Poles
According to Customer Requirements
Grounding
According to Customer Requirements
Series
Two
Run
According to Customer Requirements
Switching Mode
According to Customer Requirements
Common Model
Gw9
Structure of Operating
According to Customer Requirements
Certification
ISO, RoHS, CE
Brand
Chbeb
Customizable
OEM/According to Customer Requirements
Transport Package
Standard Shipping Packing
Specification
45*55*38mm
Trademark
CHBEB
Origin
China
HS Code
853530900
Production Capacity
5000 PCS/Quarter

Product Description

Advanced Load Break Disconnect Switch for High Voltage Outdoor Applications
Product Description

Introducing the (H)GWBEB type outdoor high-voltage isolation switch, also known as an isolation disconnect switch. This robust and reliable switch is expertly crafted for seamless use on 10(12, 15, 24)kV high voltage power transmission and distribution lines. It is designed to efficiently open and close single-phase or three-phase circuits without load, while the voltage is present. Ideal for outdoor high voltage applications, this switch offers unparalleled performance and safety.

Perfectly tailored for single-phase applications within three-phase line systems, this switch boasts a simple, yet highly effective design that ensures cost-efficiency and ease of use. It is available in an array of rated currents: 200, 400, 600, 800, 1000, and 1250 amps, catering to a diverse range of requirements. The switch's structure includes a base, sturdy post insulators, conductive components, and a sophisticated mechanical section. Its innovative gate knife design efficiently manages circuit opening and closing, with each phase's gate knife featuring two conductive blades supported by external compression springs on both sides. Adjust the spring height to achieve the optimal contact pressure for the gate knife. The switch is operable using an insulated hook stick, complemented by a self-locking mechanism for enhanced security.

Working Environment:

Designed for altitudes not exceeding 1000 meters;

Capable of withstanding ambient temperatures: maximum of +40°C and minimum of -30°C;

Engineered to operate under outdoor wind conditions up to 35 meters/second;

Resilient against seismic intensity not exceeding 8 degrees; ideally installed in locations free from frequent severe vibrations.

Installation locations should be devoid of gases, chemical deposits, salt mist, dust, dirt, or other harmful or corrosive mediums that could undermine the switch's insulation and conductivity.

Note:

FOR CONDITIONS OUTSIDE THE NORMAL RANGE, USERS ARE ENCOURAGED TO NEGOTIATE WITH THE COMPANY FOR CUSTOM SOLUTIONS.

 

Installation, Use and Adjustment

Pre-installation work

  1. Commence by carefully removing dust and dirt from components, paying special attention to the surface of the insulating porcelain bottles for optimal preparation.
  2. Diligently scrub the wiring surface of the ground screw to ensure ideal connectivity.
  3. Apply a protective layer of industrial Vaseline to all rotating parts and contact areas to maintain smooth operation.
  4. Inspect the contact surface and adjust the height of the compression springs to meet the specifications outlined in Table II, ensuring optimal contact pressure.
  5. This switch is exclusively designed for hoisting use and is intended to work in tandem with the transformer on the line, enhancing its utility.
  6. Rated currents of 200-400 ampere hours generally require three mounting holes, whereas currents of 600-1000A demand three mounting holes for secure installation.

Conduct an annual check-up on the following switch components to ensure continued performance:
Regularly remove debris from all conductive parts, contact surfaces, and the insulating porcelain bottle's exterior for optimal function.

Inspect all components for any signs of damage, with particular emphasis on ensuring the integrity of the insulating porcelain bottle.

Verify the quality and reliability of the conductive part's contact surface to maintain excellent performance.


Advanced Load Break Disconnect Switch for High Voltage Outdoor Applications

Detailed Photos

 

Advanced Load Break Disconnect Switch for High Voltage Outdoor Applications
Advanced Load Break Disconnect Switch for High Voltage Outdoor Applications
Advanced Load Break Disconnect Switch for High Voltage Outdoor Applications
Advanced Load Break Disconnect Switch for High Voltage Outdoor Applications


Advanced Load Break Disconnect Switch for High Voltage Outdoor Applications
Advanced Load Break Disconnect Switch for High Voltage Outdoor Applications

Advanced Load Break Disconnect Switch for High Voltage Outdoor Applications
Advanced Load Break Disconnect Switch for High Voltage Outdoor Applications
Advanced Load Break Disconnect Switch for High Voltage Outdoor Applications
Advanced Load Break Disconnect Switch for High Voltage Outdoor Applications
Advanced Load Break Disconnect Switch for High Voltage Outdoor Applications
Advanced Load Break Disconnect Switch for High Voltage Outdoor Applications
Advanced Load Break Disconnect Switch for High Voltage Outdoor Applications
Advanced Load Break Disconnect Switch for High Voltage Outdoor Applications
Advanced Load Break Disconnect Switch for High Voltage Outdoor Applications
Advanced Load Break Disconnect Switch for High Voltage Outdoor Applications
Advanced Load Break Disconnect Switch for High Voltage Outdoor Applications
Advanced Load Break Disconnect Switch for High Voltage Outdoor Applications

 

Product Parameters

The main technical parameters

Table I

Model

Rated voltage
kV

 

Rated current
A

kA

 

10 seconds thermal stable current
kA

peak

Valid values

 

(H)GW

 

10

12

15

200

5

9

5

400

21

15

10

600

35

25

14

630

35

25

14

800

35

25

14

1000

50

35

20

Contact force parameters

Table II

Model

Rated current(A)

contact pressure(kgf)

(H)GW

5

9

21

15

35

25

35

25

35

25

50