Medium Voltage Outdoor Isolation Switch Load Break Disconnect Options Available

Product Details
Customization: Available
Type: 10kv/12kv/15kv
Structure: According to Customer Requirements
Still deciding? Get samples of $ !
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

OEM Services
The supplier provides OEM services for popular brands
Quality Assurance
The supplier provides quality assurance
Private Mold
The supplier has private mold
Product Certification
The supplier's products already have relevant certification qualifications, including:
CE
to see all verified strength labels (20)
  • Medium Voltage Outdoor Isolation Switch Load Break Disconnect Options Available
  • Medium Voltage Outdoor Isolation Switch Load Break Disconnect Options Available
  • Medium Voltage Outdoor Isolation Switch Load Break Disconnect Options Available
  • Medium Voltage Outdoor Isolation Switch Load Break Disconnect Options Available
  • Medium Voltage Outdoor Isolation Switch Load Break Disconnect Options Available
  • Medium Voltage Outdoor Isolation Switch Load Break Disconnect Options Available
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Certifications
Overview

Basic Info.

Model NO.
(H)GWBEB
Installation
Outdoor High-voltage
Operation
Manual/Electric/Pneumatic/Hydraulic
Grounding Mode
According to Customer Requirements
Movement Mode
According to Customer Requirements
Number of Poles
According to Customer Requirements
Grounding
According to Customer Requirements
Series
Two
Run
According to Customer Requirements
Switching Mode
According to Customer Requirements
Common Model
Gw9
Structure of Operating
According to Customer Requirements
Certification
ISO, RoHS, CE
Brand
Chbeb
Customizable
OEM/According to Customer Requirements
Transport Package
Standard Shipping Packing
Specification
45*55*38mm
Trademark
CHBEB
Origin
China
HS Code
853530900
Production Capacity
5000 PCS/Quarter

Product Description

Medium Voltage Outdoor Isolation Switch Load Break Disconnect Options Available
Product Description

The (H)GWBEB type outdoor high-voltage isolation switch, also revered as an isolation disconnect switch, stands as a pinnacle of engineering precision, crafted specifically for operation on 10(12, 15, 24)kV high voltage power transmission and distribution lines. This switch excels in seamlessly opening and closing single-phase or three-phase circuits where the load is absent but voltage remains present, ensuring a reliable and efficient power management solution.

Designed for single-phase utility in three-phase line systems, this switch is a paragon of simplicity and cost-efficiency, paired with user-friendliness. It comes in a range of rated currents: 200, 400, 600, 800, 1000, and 1250 amps. Its structure comprises a robust base, durable post insulators, conductive components, and a precise mechanical section. The gate knife mechanism, featuring dual conductive blades per phase with external compression springs, facilitates effective circuit operations. Adjusting these springs' height ensures optimal contact pressure, while an insulated hook stick enables safe operation, complemented by a self-locking mechanism for enhanced security.

Working Environment:

The operational altitude should not surpass 1000 meters;

The ambient temperature must remain within a maximum of +40°C and a minimum of -30°C;

Outdoor wind speed must not exceed 35 meters/second;

Installations should withstand a seismic intensity of up to 8 degrees without succumbing to frequent, severe vibrations.

The installation environment must be devoid of gases, chemical deposits, salt mist, dust, dirt, or any other explosive or corrosive mediums that could significantly impair the switch's insulation and conductivity capabilities.

Note:

SHOULD THE ABOVE STANDARD USE CONDITIONS BE EXCEEDED, USERS ARE ADVISED TO ENTER NEGOTIATIONS WITH THE COMPANY.

Installation, Use and Adjustment

Pre-installation work

  1. Meticulously remove dust and dirt from all components and ensure the insulating porcelain bottle's surface is thoroughly cleaned.
  2. Scrub the ground screw's wiring surface to ensure optimal conductivity.
  3. Apply a protective layer of industrial Vaseline to all rotating parts and contact areas to prolong their operational integrity.
  4. Inspect the contact surface diligently and adjust the compression spring's height to ensure contact pressure aligns with Table II standards.
  5. This switch is exclusively suitable for hoisting and is expertly paired with transformers on the line for enhanced operational synergy.
  6. Rated at 200-400 ampere hours, the switch typically utilizes three mounting holes, extending to 600-1000A configurations also employing three mounting holes.

Conduct an annual inspection on the following switch components:
Thoroughly remove any dirt from conductive parts, contact surfaces, and insulating porcelain bottles to maintain optimal performance.

Inspect all components for potential damage, with particular emphasis on the insulating porcelain bottle for any signs of damage or cracks.

Ensure that the contact surface of each conductive part remains in excellent condition.


Medium Voltage Outdoor Isolation Switch Load Break Disconnect Options Available

Detailed Photos

Medium Voltage Outdoor Isolation Switch Load Break Disconnect Options Available
Medium Voltage Outdoor Isolation Switch Load Break Disconnect Options Available
Medium Voltage Outdoor Isolation Switch Load Break Disconnect Options Available
Medium Voltage Outdoor Isolation Switch Load Break Disconnect Options Available


Medium Voltage Outdoor Isolation Switch Load Break Disconnect Options Available
Medium Voltage Outdoor Isolation Switch Load Break Disconnect Options Available

Medium Voltage Outdoor Isolation Switch Load Break Disconnect Options Available
Medium Voltage Outdoor Isolation Switch Load Break Disconnect Options Available
Medium Voltage Outdoor Isolation Switch Load Break Disconnect Options Available
Medium Voltage Outdoor Isolation Switch Load Break Disconnect Options Available
Medium Voltage Outdoor Isolation Switch Load Break Disconnect Options Available
Medium Voltage Outdoor Isolation Switch Load Break Disconnect Options Available
Medium Voltage Outdoor Isolation Switch Load Break Disconnect Options Available
Medium Voltage Outdoor Isolation Switch Load Break Disconnect Options Available
Medium Voltage Outdoor Isolation Switch Load Break Disconnect Options Available
Medium Voltage Outdoor Isolation Switch Load Break Disconnect Options Available
Medium Voltage Outdoor Isolation Switch Load Break Disconnect Options Available
Medium Voltage Outdoor Isolation Switch Load Break Disconnect Options Available

Product Parameters

The main technical parameters

Table I

Model

Rated voltage
kV

 

Rated current
A

kA

 

10 seconds thermal stable current
kA

peak

Valid values

 

(H)GW

 

10

12

15

200

5

9

5

400

21

15

10

600

35

25

14

630

35

25

14

800

35

25

14

1000

50

35

20

Contact force parameters

Table II

Model

Rated current(A)

contact pressure(kgf)

(H)GW

5

9

21

15

35

25

35

25

35

25

50

35

Certifications

Medium Voltage Outdoor Isolation Switch Load Break Disconnect Options AvailableMedium Voltage Outdoor Isolation Switch Load Break Disconnect Options Available

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier