Customizable Polymeric Housed Lightning Arrester for Optimal Surge Protection

Product Details
Customization: Available
Type: Power Source Arrester
Structure: Zinc Oxide Arrester
Still deciding? Get samples of US$ 35/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

OEM Services
The supplier provides OEM services for popular brands
Quality Assurance
The supplier provides quality assurance
Private Mold
The supplier has private mold
Product Certification
The supplier's products already have relevant certification qualifications, including:
CE
to see all verified strength labels (20)
  • Customizable Polymeric Housed Lightning Arrester for Optimal Surge Protection
  • Customizable Polymeric Housed Lightning Arrester for Optimal Surge Protection
  • Customizable Polymeric Housed Lightning Arrester for Optimal Surge Protection
  • Customizable Polymeric Housed Lightning Arrester for Optimal Surge Protection
  • Customizable Polymeric Housed Lightning Arrester for Optimal Surge Protection
  • Customizable Polymeric Housed Lightning Arrester for Optimal Surge Protection
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Certifications
  • Company Profile
Overview

Basic Info.

Model NO.
YH series
Installation
According to Customer Requirements
Application
AC/DC System/Power Plants/Substation
Size
According to Customer Requirements
Operation Voltage
3 - 36kv
Shape
According to Customer Requirements
Material
ZnO
Certification
ROHS, ISO9001, CCC
Brand
Chbeb
Customizable
OEM/According to Customer Requirements
Voltage Customizable
30kv 33kv 36kv
Transport Package
Pallet
Trademark
CHBEB
Origin
China
HS Code
8535400000
Production Capacity
50000 Pieces/Quarter

Product Description

Product Description

Introducing the Zinc Oxide Arrester from Beierbian Group Co., Ltd—an extraordinary leap forward in lightning protection for 10kV power distribution systems. This groundbreaking device is meticulously engineered with a zinc oxide valve column, expertly paired with upper and lower electrodes, all impeccably encased within silicone rubber. Experience unmatched excellence with its distinctive features:

  1. This avant-garde design skillfully addresses and resolves the common sealing challenges encountered in traditional arresters. By harmoniously integrating the core and jacket into a cohesive, unified structure, it eliminates any cavities that could lead to internal breathing complications, ingeniously overcoming the technical obstacles of preventing moisture penetration within internal components.
  2. Endowed with a sturdy core that possesses a remarkable capacity to withstand internal overvoltage, this arrester exhibits outstanding aging resistance. It ensures consistent performance and steadfast protection, maintaining its superior efficacy and reliability over many years.

By employing a specially designed valve plate alongside optimized core parameters, this cutting-edge device ensures the core endures challenges such as arc grounding, PT resonance, and a variety of operational overvoltages. It operates with unrivaled reliability under line voltage and withstands 2.5 to 3 times power frequency overvoltage. Its voltage endurance surpasses international standards by 1 to 3 orders of magnitude, guaranteeing exceptional safety and enduring operational longevity.
Customizable Polymeric Housed Lightning Arrester for Optimal Surge Protection

Detailed Photos

Customizable Polymeric Housed Lightning Arrester for Optimal Surge Protection

Customizable Polymeric Housed Lightning Arrester for Optimal Surge Protection
Customizable Polymeric Housed Lightning Arrester for Optimal Surge Protection
Customizable Polymeric Housed Lightning Arrester for Optimal Surge Protection
Customizable Polymeric Housed Lightning Arrester for Optimal Surge Protection
Customizable Polymeric Housed Lightning Arrester for Optimal Surge Protection
Customizable Polymeric Housed Lightning Arrester for Optimal Surge Protection

Product Parameters

Main Characteristics Of Jacket Materials And Product Usage Environment:

Item

Unit

Norm

Shore Hardness A

/

60

Tensile Strength

mpa

≥35

Breaking Elongation

%

≥250

Oxygen Index

/

45

Resistivity

Ω.m

≥1×1013

Breakdown Strength

MV/m

≥25

Tracking

kV

4.5

Durability

Not less than 20 years

Environment Where Our Product Shines:

Ingeniously crafted for flawless performance, whether it's indoors or outdoors;

Efficiently operates at elevations soaring up to a grand 3000 meters;

Designed to brave ambient temperatures, from a frosty -40°C to a warm +60°C;

Harmonizes effortlessly with power supply frequencies ranging from 48Hz to 62Hz;

Meticulously ensures that the power frequency voltage between terminals stays within optimal ranges for extended durability.

Skillfully withstands seismic tremors with intensities not surpassing 8 degrees.

Strategically engineered to resist outdoor wind forces up to a swift 35 meters per second;

Insightful Note:

If you encounter conditions that exceed these standard operational parameters, reach out to our team to explore bespoke solutions.

State-of-the-Art Technical Parameters

Model

Nominal Voltage

(rms)

Rated Voltage OArrester

(rms)

Continuous Operating Voltage

(rms)

DC 1mA reference voltage
kV not less than

The residual voltage under nominal discharge current
kV (Crest) not greater than

Steep wave impact residual voltage
kV (Crest) not greater than

2ms square wave flow capacity
A

Operation Place

YH5WS-3.8/17

3

3.8

2.0

7.5

17.0

19.6

100

 

Distribution Type

YH5WS-5/15

3

5

4.0

7.5

15.0

17.3

150

YH5WS-7.6/30

6

7.6

4.0

15.0

15.0

34.5

100

YH5WS-10/30

6

10

8.0

15.0

30.0

34.6

150

YH5WS-12.7/50

10

12.7

10

26.0

50.0

57.5

100

YH5WS-16.5/50

10

16.5

12.7

26.0

50.0

57.5

100

YH5WS-17/50

10

17

13.6

26.0

50.0

57.5

150

YH5WS-17/45

10

17

13.6

25.0

45.0

/

250

YH10WS-17/45

10

17

13.6

25.0

45.0

/

400

YH5WZ-5/13.5

3

5

4.0

7.2

13.5

15.5

200

Power Station Type

YH5WZ-7.6/27

6

7.6

4.0

14.4

27.0

31.0

150

YH5WZ-10/27

6

10

8.0

14.4

27.0

31.0

200

YH5WZ-42/134

35

42

23.4

73

134

154

150

YH5WZ-12.7/45

10

12.7

6.6

24.0

45.0

51.8

150

YH5WZ-16.5/45

10

16.5

13.2

24.0

45.0

51.8

150

YH5WZ-17/45

10

17

13.6

24.0

45.0

51.8

200

YH5WZ-51/134

35

51

40.8

73.0

134

154

400

YH10WZ-17/45

10

17

13.6

24.0

45.0

51.8

200

YH10WZ-51/134

35

51

40.8

73.0

134

154

400

YH5WR-5/13.5

3

5

4.0

7.2

13.5

/

400

Capacitive Type

YH5WR-7.6/27

6

7.6

4.0

13.8

27.0

/

400

YH5WR-10/27

6

10

8.0

14.4

27.0

/

400

YH5WR-12.7/45

10

12.7

6.6

23.0

45.0

/

400

YH5WR 17/45

10

17

13.6

24.0

45.0

/

400

YH5WX-51/134

35

51

40.8

73

134.0

154

400

Line type

YH1.5W-30/80

35

30

24

44

80.0

/

600

Neutral Type

Note: Boasts a resilient Polymeric construction

Model

Nominal Voltage

(rms)

Rated Voltage OArrester

(rms)

Continuous Operating Voltage

(rms)

DC 1mA Reference Voltage
kV Not Less Than

The Residual Voltage Under Nominal Discharge Current
kV (Crest)
Not Greater Than

Steep Wave Impact Residual Voltage
kV (Crest)
Not Greater Than

2ms Square Wave Flow Capacity
A

Operation Place

Y5WS-5/15

3

5

4.0

7.5

15.0

17.3

150

Distribution Type

Y5WS-7.6/30

6

7.6

4.0

15.0

15.0

34.5

100

Y5WS-10/30

6

10

8.0

15.0

30.0

34.6

150

Y5WS-12.7/50

10

12.7

10

26.0

50.0

57.5

100

Y5WS-16.5/50

10

16.5

12.7

26.0

50.0

57.5

100

Y5WS-17/50

10

17

13.6

26.0

50.0

57.5

150

Y5WZ-5/13.5

3

5

4.0

7.2

13.5

15.5

200

Power Station Type

Y5WZ-7.6/27

6

7.6

4.0

14.4

27.0

31.0

150

Y5WZ-10/27

6

10

8.0

14.4

27.0

31.0

200

Y5WZ-42/134

35

42

23.4

73

134

154

150

Y5WZ-12.7/45

10

12.7

6.6

24.0

45.0

51.8

150

Y5WZ-16.5/45

10

16.5

13.2

24.0

45.0

51.8

150

Y5WZ-17/45

10

17

13.6

24.0

45.0

51.8

200

Y5WZ-51/134

35

51

40.8

73.0

134

154

400

Y5WR-5/13.5

3

5

4.0

7.2

13.5

/

400

Capacitive Type

Y5WR-7.6/27

6

7.6

4.0

13.8

27.0

/

400

Y5WR-10/27

6

10

8.0

14.4

27.0

/

400

Y5WR-12.7/45

10

12.7

6.6

23.0

45.0

/

400

Y5WR-17/45

10

17

13.6

24.0

45.0

/

400

Y1.5W-0.28/1.3

0.22

0.28

0.24

0.6

1.3

/

75

Low Voltage

Y1.5W-0.5/2.6

0.38

0.5

0.24

1.2

2.6

/

75

Note:Porcelain

Model

 

Nominal Voltage
(Valid values)

 

Rated Voltage Of Arrester
(Valid values)

 

The Wave Front

Steepness Of The Shock Discharge

 

DC 1mA Reference Voltage

kV Not Less Than

 

1.2/50 Impulse Discharge Voltage

Not Greater Than

 

Wavefront Impulse

Discharge Voltage

 

kV Not Greater Than

The Residual Voltage Under Nominal Discharge

Current 8/20μs

 

kV Not Greater Than

 

2000μs Square

Wave Flow Capacity

 

4/10μs Impulse

Current Capacity

Y5CS-7.6/27

6

7.6

63

16

35

43.8

27

75

25

Y5CZ-7.6/24

6

7.6

63

16

30

37.5

24

150

40

Y5CS-12.7/45

10

12.7

106

26

50

62.5

45

75

25

Y5CS-12.7/41

10

12.7

106

26

45

56.5

41

200

40

Y5CZ-42/124

35

42.0

343

82

134

168

124

200

40

Note: Comes with the detailed specification of Porcelain Series Gap

Installation Guidelines

(1) Before installation, confirm the nameplate to ensure the arrester's rated voltage matches the system voltage at the installation site;

(2) Provides versatile options with suspension or vertical installation. For vertical installation, ensure the arrester is not used as a load-supporting insulator;

(3) Optimize the lead wire length to maintain protection efficiency and reduce stress on the equipment seamlessly.

Testing Protocols

  • To boost operational reliability, preventive tests every 4-5 years are advocated. Focus on measuring U1mA at both terminals of the DC 1mA arrester.
  • Prior to installation, confirm the U1mA voltage is at least 97% of the original factory value and meticulously document this data.
  • During maintenance, ensure the U1mA voltage remains above 26kV.
  • Note: Minimize harmonic components in the DC power supply during tests to avoid low U1mA readings due to poor waveforms.
  • The newly launched 10kV synthetic insulated zinc oxide arrester for power distribution has triumphantly passed exhaustive lab tests, maintaining robust functionality under outdoor line voltage for an impressive 15 months. These findings highlight: the jacket's superior quality, structural reliability of the arrester, and core stability. Along with annual performance data from 2,000 units, this product guarantees premium protection, minimized failure occurrence, and a maintenance-free lifespan.Customizable Polymeric Housed Lightning Arrester for Optimal Surge Protection
Certifications

Customizable Polymeric Housed Lightning Arrester for Optimal Surge Protection

Company Profile

Customizable Polymeric Housed Lightning Arrester for Optimal Surge Protection

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier