Customization: | Available |
---|---|
Breaking Capacity: | 12kv/24kv/40.5kv |
Type: | Current Fuse |
Still deciding? Get samples of US$ 30/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
(H) RW(F) series outdoor high voltage AC drop fuse is ingeniously designed for outdoor overhead distribution systems with a standard frequency of 50Hz and voltage ratings of 10kV, 12kV, 15kV, 35kV, and 40.5kV. This robust fuse serves as a crucial protective element against overloads and short circuits, safeguarding your circuits and electrical equipment. During normal operations, this fuse integrates seamlessly into the power line, maintaining a tensioned state with a locked movable joint for reliability. Should a fault arise, the swift response of the fuse to the fault current ensures immediate disconnection as the fuse blows, releasing the joint, and dropping the fuse tube efficiently to cut off the circuit. This is vital for the safe maintenance of lines and equipment. Enhanced with elastic contact and an arc extinguishing cover, the load type fuse excels in opening and closing load currents proficiently within the power system.
The fuse is manufactured to meet stringent technical standards including GB / T 15166.3 - 2008 for high voltage AC fuses - Part 3: injection fuses, and DL / T 640 - 1997 for outdoor AC high voltage drop tested fuses and fuse links ordering technical conditions. These standards ensure the highest reliability and safety.
Working Environment:
Ambient temperature ranges from a frigid -40°C to a warm +40°C, allowing versatile use.
Relative humidity: the daily average should not exceed 95%, with a monthly average cap at 90%, ensuring stability under various conditions.
The operational altitude is up to 3000 meters, providing flexibility for diverse installations.
Designed to withstand outdoor wind speeds up to 34 meters/second, ensuring durability against harsh weather.
The installation site must be free of fire risks, explosion hazards, and chemical corrosive gases, and should be well-ventilated to ensure optimal performance.
Note: For conditions beyond the specified normal use parameters, custom solutions can be negotiated with Beierbian Group Co., Ltd to meet your specific needs.
Technical parameters
Note: Our company is adept at supplying products tailored to user specifications, ensuring precision and satisfaction.
Model |
Voltage |
Current |
Rated maximum
breaking current |
1min power frequency dry withstand
voltage |
1min power frequency wet withstand
voltage |
Rated lightning impulse withstand
voltage |
Opening and closing
load current |
XS-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
XS-15/100(200) |
15 |
||||||
PD-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
PD-15/100(200) |
15 |
||||||
(H)RW3-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW3-12/100(200) |
12 |
||||||
(H)RW4-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW4-12/100(200) |
12 |
||||||
(H)RW7-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW7-12/100(200) |
12 |
||||||
(H)RW10-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW10-12/100(200) |
12 |
||||||
(H)RW10-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW10-12F/100(200) |
12 |
||||||
(H)RW11-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
! |
(H)RW11-12/100(200) |
12 |
||||||
(H)RW11-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW11-12F/100(200) |
12 |
||||||
(H)RW12-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
45 |
30 |
105 |
/ |
(H)RW12-12/100(200) |
12 |
||||||
(H)RW12-15/100(200) |
15 |
||||||
(H)PRWG1-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)PRWG1-12F/100(200) |
12 |
||||||
(H)RW33-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW33-15/100(200) |
15 |
||||||
(H)RW5-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)RW10-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)PRWG2-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |