Innovative Customizable Surge Arrester for Effective Voltage Protection Needs

Product Details
Customization: Available
Type: Power Source Arrester
Structure: Zinc Oxide Arrester
Still deciding? Get samples of $ !
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

OEM Services
The supplier provides OEM services for popular brands
Quality Assurance
The supplier provides quality assurance
Private Mold
The supplier has private mold
Product Certification
The supplier's products already have relevant certification qualifications, including:
CE
to see all verified strength labels (20)
  • Innovative Customizable Surge Arrester for Effective Voltage Protection Needs
  • Innovative Customizable Surge Arrester for Effective Voltage Protection Needs
  • Innovative Customizable Surge Arrester for Effective Voltage Protection Needs
  • Innovative Customizable Surge Arrester for Effective Voltage Protection Needs
  • Innovative Customizable Surge Arrester for Effective Voltage Protection Needs
  • Innovative Customizable Surge Arrester for Effective Voltage Protection Needs
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Certifications
  • Company Profile
Overview

Basic Info.

Model NO.
YH series
Installation
According to Customer Requirements
Application
AC/DC System/Power Plants/Substation
Size
According to Customer Requirements
Operation Voltage
3 - 36kv
Shape
According to Customer Requirements
Material
ZnO
Certification
ROHS, ISO9001, CCC
Brand
Chbeb
Customizable
OEM/According to Customer Requirements
Voltage Customizable
30kv 33kv 36kv
Transport Package
Pallet
Trademark
CHBEB
Origin
China
HS Code
8535400000
Production Capacity
50000 Pieces/Quarter

Product Description

Product Description

Introducing the Zinc Oxide Arrester from Beierbian Group Co., Ltd—a groundbreaking, fully sealed, and exceptionally dependable lightning protection solution for 10kV power distribution systems. This state-of-the-art device is expertly engineered using a zinc oxide valve assembly, enhanced by upper and lower electrodes, all expertly encased in silicone rubber. Its unparalleled features include:

  1. This cutting-edge design expertly tackles and resolves the sealing issues traditionally faced in arresters. By seamlessly integrating the core and jacket into a unified, compact structure, it eliminates any cavities that could potentially cause internal breathing problems, thereby ingeniously overcoming the technical hurdles associated with preventing moisture ingress in internal components.
  2. Featuring a robust core with an exceptional capacity to withstand internal overvoltage, this arrester demonstrates remarkable aging resistance, ensuring consistent performance and steadfast protection over the years.

With a specially designed valve plate combined with optimized core parameters, this device ensures the core handles challenges such as arc grounding, PT resonance, and a wide range of operational overvoltages with ease. It operates with unrivaled reliability under line voltage and can endure 2.5 to 3 times power frequency overvoltage. Its voltage withstand duration exceeds international standards by 1 to 3 orders of magnitude, offering unmatched safety and operational longevity.
Innovative Customizable Surge Arrester for Effective Voltage Protection Needs

Detailed Photos

Innovative Customizable Surge Arrester for Effective Voltage Protection Needs

Innovative Customizable Surge Arrester for Effective Voltage Protection Needs
Innovative Customizable Surge Arrester for Effective Voltage Protection Needs
Innovative Customizable Surge Arrester for Effective Voltage Protection Needs
Innovative Customizable Surge Arrester for Effective Voltage Protection Needs
Innovative Customizable Surge Arrester for Effective Voltage Protection Needs
Innovative Customizable Surge Arrester for Effective Voltage Protection Needs

Product Parameters

Main Characteristics Of Jacket Materials And Product Usage Environment:

Item

Unit

Norm

Shore Hardness A

/

60

Tensile Strength

mpa

≥35

Breaking Elongation

%

≥250

Oxygen Index

/

45

Resistivity

Ω.m

≥1×1013

Breakdown Strength

MV/m

≥25

Tracking

kV

4.5

Durability

Not less than 20 years

Working Environment:

Expertly crafted for impeccable performance in both indoor and outdoor settings;

Efficiently operates even at impressive altitudes reaching up to 3000 meters;

Designed to thrive in ambient temperatures ranging from a brisk -40°C to a warm +60°C;

Seamlessly adapts to power supply frequencies varying from a stable 48Hz to a vibrant 62Hz;

Guarantees that the power frequency voltage applied across terminals stays within optimal limits for extended durability.

Built to withstand seismic forces with an intensity up to 8 degrees, ensuring resilience in shaky conditions.

Constructed to resist outdoor wind velocities surging up to 35 meters per second;

Note:

If you experience conditions that surpass these standard operational parameters, we encourage you to reach out for bespoke solutions with our expert team.

Main technical parameters

Model

Nominal Voltage

(rms)

Rated Voltage OArrester

(rms)

Continuous Operating Voltage

(rms)

DC 1mA reference voltage
kV not less than

The residual voltage under nominal discharge current
kV (Crest) not greater than

Steep wave impact residual voltage
kV (Crest) not greater than

2ms square wave flow capacity
A

Operation Place

YH5WS-3.8/17

3

3.8

2.0

7.5

17.0

19.6

100

 

Distribution Type

YH5WS-5/15

3

5

4.0

7.5

15.0

17.3

150

YH5WS-7.6/30

6

7.6

4.0

15.0

15.0

34.5

100

YH5WS-10/30

6

10

8.0

15.0

30.0

34.6

150

YH5WS-12.7/50

10

12.7

10

26.0

50.0

57.5

100

YH5WS-16.5/50

10

16.5

12.7

26.0

50.0

57.5

100

YH5WS-17/50

10

17

13.6

26.0

50.0

57.5

150

YH5WS-17/45

10

17

13.6

25.0

45.0

/

250

YH10WS-17/45

10

17

13.6

25.0

45.0

/

400

YH5WZ-5/13.5

3

5

4.0

7.2

13.5

15.5

200

Power Station Type

YH5WZ-7.6/27

6

7.6

4.0

14.4

27.0

31.0

150

YH5WZ-10/27

6

10

8.0

14.4

27.0

31.0

200

YH5WZ-42/134

35

42

23.4

73

134

154

150

YH5WZ-12.7/45

10

12.7

6.6

24.0

45.0

51.8

150

YH5WZ-16.5/45

10

16.5

13.2

24.0

45.0

51.8

150

YH5WZ-17/45

10

17

13.6

24.0

45.0

51.8

200

YH5WZ-51/134

35

51

40.8

73.0

134

154

400

YH10WZ-17/45

10

17

13.6

24.0

45.0

51.8

200

YH10WZ-51/134

35

51

40.8

73.0

134

154

400

YH5WR-5/13.5

3

5

4.0

7.2

13.5

/

400

Capacitive Type

YH5WR-7.6/27

6

7.6

4.0

13.8

27.0

/

400

YH5WR-10/27

6

10

8.0

14.4

27.0

/

400

YH5WR-12.7/45

10

12.7

6.6

23.0

45.0

/

400

YH5WR 17/45

10

17

13.6

24.0

45.0

/

400

YH5WX-51/134

35

51

40.8

73

134.0

154

400

Line type

YH1.5W-30/80

35

30

24

44

80.0

/

600

Neutral Type

Note: Showcasing a durable Polymeric construction for long-lasting reliability.

Model

Nominal Voltage

(rms)

Rated Voltage OArrester

(rms)

Continuous Operating Voltage

(rms)

DC 1mA Reference Voltage
kV Not Less Than

The Residual Voltage Under Nominal Discharge Current
kV (Crest)
Not Greater Than

Steep Wave Impact Residual Voltage
kV (Crest)
Not Greater Than

2ms Square Wave Flow Capacity
A

Operation Place

Y5WS-5/15

3

5

4.0

7.5

15.0

17.3

150

Distribution Type

Y5WS-7.6/30

6

7.6

4.0

15.0

15.0

34.5

100

Y5WS-10/30

6

10

8.0

15.0

30.0

34.6

150

Y5WS-12.7/50

10

12.7

10

26.0

50.0

57.5

100

Y5WS-16.5/50

10

16.5

12.7

26.0

50.0

57.5

100

Y5WS-17/50

10

17

13.6

26.0

50.0

57.5

150

Y5WZ-5/13.5

3

5

4.0

7.2

13.5

15.5

200

Power Station Type

Y5WZ-7.6/27

6

7.6

4.0

14.4

27.0

31.0

150

Y5WZ-10/27

6

10

8.0

14.4

27.0

31.0

200

Y5WZ-42/134

35

42

23.4

73

134

154

150

Y5WZ-12.7/45

10

12.7

6.6

24.0

45.0

51.8

150

Y5WZ-16.5/45

10

16.5

13.2

24.0

45.0

51.8

150

Y5WZ-17/45

10

17

13.6

24.0

45.0

51.8

200

Y5WZ-51/134

35

51

40.8

73.0

134

154

400

Y5WR-5/13.5

3

5

4.0

7.2

13.5

/

400

Capacitive Type

Y5WR-7.6/27

6

7.6

4.0

13.8

27.0

/

400

Y5WR-10/27

6

10

8.0

14.4

27.0

/

400

Y5WR-12.7/45

10

12.7

6.6

23.0

45.0

/

400

Y5WR-17/45

10

17

13.6

24.0

45.0

/

400

Y1.5W-0.28/1.3

0.22

0.28

0.24

0.6

1.3

/

75

Low Voltage

Y1.5W-0.5/2.6

0.38

0.5

0.24

1.2

2.6

/

75

Note:Porcelain

Model

 

Nominal Voltage
(Valid values)

 

Rated Voltage Of Arrester
(Valid values)

 

The Wave Front

Steepness Of The Shock Discharge

 

DC 1mA Reference Voltage

kV Not Less Than

 

1.2/50 Impulse Discharge Voltage

Not Greater Than

 

Wavefront Impulse

Discharge Voltage

 

kV Not Greater Than

The Residual Voltage Under Nominal Discharge

Current 8/20μs

 

kV Not Greater Than

 

2000μs Square

Wave Flow Capacity

 

4/10μs Impulse

Current Capacity

Y5CS-7.6/27

6

7.6

63

16

35

43.8

27

75

25

Y5CZ-7.6/24

6

7.6

63

16

30

37.5

24

150

40

Y5CS-12.7/45

10

12.7

106

26

50

62.5

45

75

25

Y5CS-12.7/41

10

12.7

106

26

45

56.5

41

200

40

Y5CZ-42/124

35

42.0

343

82

134

168

124

200

40

Note: Incorporates Porcelain Series Gap specification for enhanced protection.

Installation

(1) Before commencing installation, check the nameplate to confirm the arrester's system rated voltage is compatible with the installation site's system voltage;

(2) Offers versatile installation options with suspension or vertical configurations. When choosing vertical installation, ensure the arrester is not used as a load-bearing insulator;

(3) Optimize the lead wire length to maintain protection efficiency while avoiding excessive stress on equipment.

Test

  • lTo enhance operational reliability, conduct preventive tests every 4-5 years, focusing on measuring U1mA at both terminals of the DC 1mA arrester.
  • lBefore installation, ensure the U1mA voltage is no less than 97% of the initial factory value and make a thorough record of this measurement.
  • lDuring preventive maintenance, confirm the U1mA voltage remains above 26kV to ensure ongoing effectiveness.
  • lNote: Minimize harmonic distortions in the DC power supply during tests, as poor waveforms can lead to reduced U1mA readings.
  • lThe latest 10kV synthetic insulated zinc oxide arrester for power distribution has successfully undergone stringent laboratory testing, exhibiting steadfast performance under outdoor line voltage for 15 months. Results affirm the jacket's superior quality, the arrester’s structural reliability, and core stability. Alongside annual performance data from 2,000 units, this product assures exceptional protection, diminished failure rates, and a maintenance-free lifespan.Innovative Customizable Surge Arrester for Effective Voltage Protection Needs
Certifications

Innovative Customizable Surge Arrester for Effective Voltage Protection Needs

Company Profile

Innovative Customizable Surge Arrester for Effective Voltage Protection Needs

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier