Customization: | Available |
---|---|
Breaking Capacity: | 12kv/24kv/40.5kv |
Type: | Current Fuse |
Still deciding? Get samples of US$ 30/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
(H) RW(F) Series: Discover the pinnacle of safety and innovation with our outdoor high voltage AC drop fuse, affectionately termed the 'fuse' in professional circles. Tailored for the rigorous demands of outdoor overhead distribution systems, this marvel supports a formidable rated frequency of 50Hz and versatile rated voltages of 10kV (12/15/35/40.5). As the quintessential protector, it safeguards circuits and electrical equipment from the perils of overloads or short circuits within power systems. In seamless operation, it integrates into the power line, staying tensioned and locked at its movable joint. Upon detecting a fault, the fault current activates the fuse, causing it to blow; the joint releases, the fuse tube swiftly disengages, and the circuit is efficiently severed, ensuring paramount safety for line and equipment maintenance. Distinguished from ordinary types, our load type fuse boasts an elastic contact and an advanced arc extinguishing cover, adeptly managing the load current within power systems.
Our fuse proudly adheres to stringent technical standards, including GB / T 15166.3 - 2008, which pertains to high voltage AC fuses - Part 3: injection fuses, as well as DL / T 640 - 1997, concerning outdoor AC high voltage drop tested fuses and fuse links ordering technical conditions.
Optimal Working Environment:
Ambient Temperature: A robust range from -40°C to +40°C;
Relative Humidity: Daily mean not exceeding 95%, with a monthly mean under 90%;
Altitude: Performance guaranteed at heights up to 3000m;
Wind Conditions: Suitable for outdoor wind speeds up to 34 meters/second;
Installation Site: Ensure a location devoid of fire, explosion hazards, chemical corrosive gases, while ensuring it is well-ventilated.
Note: For conditions surpassing standard operational limits, users are encouraged to engage in a consultative dialogue with our company.
Technical Parameters
Note: We are committed to customizing products to align with user-specific needs.
Model |
Voltage |
Current |
Rated maximum
breaking current |
1min power frequency dry withstand
voltage |
1min power frequency wet withstand
voltage |
Rated lightning impulse withstand
voltage |
Opening and closing
load current |
XS-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
XS-15/100(200) |
15 |
||||||
PD-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
PD-15/100(200) |
15 |
||||||
(H)RW3-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW3-12/100(200) |
12 |
||||||
(H)RW4-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW4-12/100(200) |
12 |
||||||
(H)RW7-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW7-12/100(200) |
12 |
||||||
(H)RW10-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW10-12/100(200) |
12 |
||||||
(H)RW10-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW10-12F/100(200) |
12 |
||||||
(H)RW11-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
! |
(H)RW11-12/100(200) |
12 |
||||||
(H)RW11-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW11-12F/100(200) |
12 |
||||||
(H)RW12-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
45 |
30 |
105 |
/ |
(H)RW12-12/100(200) |
12 |
||||||
(H)RW12-15/100(200) |
15 |
||||||
(H)PRWG1-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)PRWG1-12F/100(200) |
12 |
||||||
(H)RW33-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW33-15/100(200) |
15 |
||||||
(H)RW5-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)RW10-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)PRWG2-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |