Introducing the state-of-the-art Zinc Oxide Arrester from Beierbian Group Co., Ltd—an exceptional advancement in lightning protection technology, tailor-made for 10kV power distribution systems. This groundbreaking device stands at the forefront of innovation, meticulously crafted with a zinc oxide valve column. It is seamlessly enhanced by the precise placement of upper and lower electrodes, all encased in superior silicone rubber. This sophisticated assembly offers unparalleled features:
With the integration of a specially engineered valve plate complemented by optimized core parameters, this device guarantees that the core can adeptly handle challenges such as arc grounding, PT resonance, and a broad range of operational overvoltages. It operates with unmatched reliability, confidently maintaining performance under normal line voltage, and enduring 2.5 to 3 times power frequency overvoltage. Its voltage withstand duration not only meets but far exceeds international standards by 1 to 3 orders of magnitude, delivering unparalleled safety and exceptional operational longevity.
Main Characteristics Of Jacket Materials And Product Usage Environment:
Item |
Unit |
Norm |
Shore Hardness A |
/ |
60 |
Tensile Strength |
mpa |
≥35 |
Breaking Elongation |
% |
≥250 |
Oxygen Index |
/ |
45 |
Resistivity |
Ω.m |
≥1×1013 |
Breakdown Strength |
MV/m |
≥25 |
Tracking |
kV |
4.5 |
Durability |
Not less than 20 years |
Working Environment:
Meticulously crafted to ensure seamless and flawless functionality, whether utilized indoors or braving the elements outdoors;
Engineered to guarantee effective operation even at soaring altitudes reaching an impressive 3000 meters, making it exceptionally versatile;
Constructed to withstand a broad spectrum of ambient temperatures, ranging from a biting -40°C to a soothing +60°C, ensuring resilience and adaptability;
Expertly designed to harmonize with power supply frequencies, accommodating a steady 48Hz to a dynamic 62Hz, ensuring versatility across applications;
Assures that the power frequency voltage applied between terminals remains within optimal limits, enhancing reliability and longevity of operation.
Robustly built to endure seismic activities with an intensity up to 8 degrees, ensuring stability and safety during quakes.
Designed to withstand fierce outdoor wind speeds up to 35 meters per second, guaranteeing durability in harsh conditions;
Note:
Facing conditions beyond these operational parameters? Our dedicated team is on standby to discuss bespoke, tailored solutions to meet your unique needs.
Main Technical Parameters
Model |
Nominal Voltage (rms) |
Rated Voltage Of Arrester (rms) |
Continuous Operating Voltage (rms) |
DC 1mA reference voltage |
The residual voltage under nominal discharge current |
Steep wave impact residual voltage |
2ms square wave flow capacity |
Operation Place |
YH5WS-3.8/17 |
3 |
3.8 |
2.0 |
7.5 |
17.0 |
19.6 |
100 |
Distribution Type |
YH5WS-5/15 |
3 |
5 |
4.0 |
7.5 |
15.0 |
17.3 |
150 |
|
YH5WS-7.6/30 |
6 |
7.6 |
4.0 |
15.0 |
15.0 |
34.5 |
100 |
|
YH5WS-10/30 |
6 |
10 |
8.0 |
15.0 |
30.0 |
34.6 |
150 |
|
YH5WS-12.7/50 |
10 |
12.7 |
10 |
26.0 |
50.0 |
57.5 |
100 |
|
YH5WS-16.5/50 |
10 |
16.5 |
12.7 |
26.0 |
50.0 |
57.5 |
100 |
|
YH5WS-17/50 |
10 |
17 |
13.6 |
26.0 |
50.0 |
57.5 |
150 |
|
YH5WS-17/45 |
10 |
17 |
13.6 |
25.0 |
45.0 |
/ |
250 |
|
YH10WS-17/45 |
10 |
17 |
13.6 |
25.0 |
45.0 |
/ |
400 |
|
YH5WZ-5/13.5 |
3 |
5 |
4.0 |
7.2 |
13.5 |
15.5 |
200 |
Power Station Type |
YH5WZ-7.6/27 |
6 |
7.6 |
4.0 |
14.4 |
27.0 |
31.0 |
150 |
|
YH5WZ-10/27 |
6 |
10 |
8.0 |
14.4 |
27.0 |
31.0 |
200 |
|
YH5WZ-42/134 |
35 |
42 |
23.4 |
73 |
134 |
154 |
150 |
|
YH5WZ-12.7/45 |
10 |
12.7 |
6.6 |
24.0 |
45.0 |
51.8 |
150 |
|
YH5WZ-16.5/45 |
10 |
16.5 |
13.2 |
24.0 |
45.0 |
51.8 |
150 |
|
YH5WZ-17/45 |
10 |
17 |
13.6 |
24.0 |
45.0 |
51.8 |
200 |
|
YH5WZ-51/134 |
35 |
51 |
40.8 |
73.0 |
134 |
154 |
400 |
|
YH10WZ-17/45 |
10 |
17 |
13.6 |
24.0 |
45.0 |
51.8 |
200 |
|
YH10WZ-51/134 |
35 |
51 |
40.8 |
73.0 |
134 |
154 |
400 |
|
YH5WR-5/13.5 |
3 |
5 |
4.0 |
7.2 |
13.5 |
/ |
400 |
Capacitive Type |
YH5WR-7.6/27 |
6 |
7.6 |
4.0 |
13.8 |
27.0 |
/ |
400 |
|
YH5WR-10/27 |
6 |
10 |
8.0 |
14.4 |
27.0 |
/ |
400 |
|
YH5WR-12.7/45 |
10 |
12.7 |
6.6 |
23.0 |
45.0 |
/ |
400 |
|
YH5WR 17/45 |
10 |
17 |
13.6 |
24.0 |
45.0 |
/ |
400 |
|
YH5WX-51/134 |
35 |
51 |
40.8 |
73 |
134.0 |
154 |
400 |
Line type |
YH1.5W-30/80 |
35 |
30 |
24 |
44 |
80.0 |
/ |
600 |
Neutral Type |
Note: Features an enduring and resilient Polymeric construction, promising long-lasting performance.
Model |
Nominal Voltage (rms) |
Rated Voltage Of Arrester (rms) |
Continuous Operating Voltage (rms) |
DC 1mA Reference Voltage |
The Residual Voltage Under Nominal Discharge Current |
Steep Wave Impact Residual Voltage |
2ms Square Wave Flow Capacity |
Operation Place |
Y5WS-5/15 |
3 |
5 |
4.0 |
7.5 |
15.0 |
17.3 |
150 |
Distribution Type |
Y5WS-7.6/30 |
6 |
7.6 |
4.0 |
15.0 |
15.0 |
34.5 |
100 |
|
Y5WS-10/30 |
6 |
10 |
8.0 |
15.0 |
30.0 |
34.6 |
150 |
|
Y5WS-12.7/50 |
10 |
12.7 |
10 |
26.0 |
50.0 |
57.5 |
100 |
|
Y5WS-16.5/50 |
10 |
16.5 |
12.7 |
26.0 |
50.0 |
57.5 |
100 |
|
Y5WS-17/50 |
10 |
17 |
13.6 |
26.0 |
50.0 |
57.5 |
150 |
|
Y5WZ-5/13.5 |
3 |
5 |
4.0 |
7.2 |
13.5 |
15.5 |
200 |
Power Station Type |
Y5WZ-7.6/27 |
6 |
7.6 |
4.0 |
14.4 |
27.0 |
31.0 |
150 |
|
Y5WZ-10/27 |
6 |
10 |
8.0 |
14.4 |
27.0 |
31.0 |
200 |
|
Y5WZ-42/134 |
35 |
42 |
23.4 |
73 |
134 |
154 |
150 |
|
Y5WZ-12.7/45 |
10 |
12.7 |
6.6 |
24.0 |
45.0 |
51.8 |
150 |
|
Y5WZ-16.5/45 |
10 |
16.5 |
13.2 |
24.0 |
45.0 |
51.8 |
150 |
|
Y5WZ-17/45 |
10 |
17 |
13.6 |
24.0 |
45.0 |
51.8 |
200 |
|
Y5WZ-51/134 |
35 |
51 |
40.8 |
73.0 |
134 |
154 |
400 |
|
Y5WR-5/13.5 |
3 |
5 |
4.0 |
7.2 |
13.5 |
/ |
400 |
Capacitive Type |
Y5WR-7.6/27 |
6 |
7.6 |
4.0 |
13.8 |
27.0 |
/ |
400 |
|
Y5WR-10/27 |
6 |
10 |
8.0 |
14.4 |
27.0 |
/ |
400 |
|
Y5WR-12.7/45 |
10 |
12.7 |
6.6 |
23.0 |
45.0 |
/ |
400 |
|
Y5WR-17/45 |
10 |
17 |
13.6 |
24.0 |
45.0 |
/ |
400 |
|
Y1.5W-0.28/1.3 |
0.22 |
0.28 |
0.24 |
0.6 |
1.3 |
/ |
75 |
Low Voltage |
Y1.5W-0.5/2.6 |
0.38 |
0.5 |
0.24 |
1.2 |
2.6 |
/ |
75 |
|
Note:Porcelain |
Model |
Nominal Voltage |
Rated Voltage Of Arrester |
The Wave Front Steepness Of The Shock Discharge |
DC 1mA Reference Voltage kV Not Less Than |
1.2/50 Impulse Discharge Voltage Not Greater Than |
Wavefront Impulse Discharge Voltage
kV Not Greater Than |
The Residual Voltage Under Nominal Discharge Current 8/20μs
kV Not Greater Than |
2000μs Square Wave Flow Capacity |
4/10μs Impulse Current Capacity |
Y5CS-7.6/27 |
6 |
7.6 |
63 |
16 |
35 |
43.8 |
27 |
75 |
25 |
Y5CZ-7.6/24 |
6 |
7.6 |
63 |
16 |
30 |
37.5 |
24 |
150 |
40 |
Y5CS-12.7/45 |
10 |
12.7 |
106 |
26 |
50 |
62.5 |
45 |
75 |
25 |
Y5CS-12.7/41 |
10 |
12.7 |
106 |
26 |
45 |
56.5 |
41 |
200 |
40 |
Y5CZ-42/124 |
35 |
42.0 |
343 |
82 |
134 |
168 |
124 |
200 |
40 |
Note: Incorporates advanced Porcelain Series Gap specifications, enhancing performance and dependability.
Installation
(1) Before installation, verify the nameplate to ensure the arrester's system rated voltage matches the installation site's system voltage perfectly;
(2) Offers flexible installation options, either suspension or vertical. For vertical setups, ensure the arrester isn't used as a load-bearing insulator;
(3) Optimize lead wire length to maintain protection efficiency and prevent unnecessary stress on the equipment, securing long-term dependability.
Test