Customization: | Available |
---|---|
Breaking Capacity: | 12kv/24kv/40.5kv |
Type: | Current Fuse |
Still deciding? Get samples of US$ 30/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
(H) RW(F) Series Outdoor High Voltage AC Drop Fuse (referred to as 'fuse') is meticulously designed for outdoor overhead distribution systems. With a rated frequency of 50Hz and a robust rated voltage of 10kV (12/15/35/40.5), it serves as an essential protective component for circuits or electrical equipment, effectively safeguarding against overload or short circuit faults in power systems. During normal operations, the fuse, securely tensioned and locked at its movable joint, is connected in series within the power line. In the event of a fault, the fault current triggers the fuse to blow, promptly releasing the movable joint. This action swiftly drops the fuse tube, cutting off the circuit to ensure safety and protection for line and equipment maintenance. Enhanced with an elastic contact and arc extinguishing cover, the load type fuse is adept at efficiently opening and closing the load current within the power system.
Adhering to rigorous technical standards, the fuse complies with GB / T 15166.3 - 2008 High Voltage AC Fuses - Part 3: Injection Fuses, and DL / T 640 - 1997 Outdoor AC High Voltage Drop Tested Fuses and Fuse Links Ordering Technical Conditions, ensuring top-tier quality and dependability.
Working Environment:
Ambient Temperature: -40°C to +40°C;
Humidity Levels: The daily average relative humidity is no more than 95%, with the monthly average not exceeding 90%;
Altitude: Not exceeding 3000 meters;
Wind Conditions: Outdoor wind speeds should not exceed 34 meters/second;
Installation Site: A site free from fire hazards, explosion risks, and chemical corrosive gases, with good ventilation.
Note: Should user requirements exceed these standard conditions, negotiations with the company are welcome to tailor solutions.
Technical Parameters
Note: Our company is committed to catering to user specifications and can supply products tailored to specific requirements.
Model |
Voltage |
Current |
Rated maximum
breaking current |
1min power frequency dry withstand
voltage |
1min power frequency wet withstand
voltage |
Rated lightning impulse withstand
voltage |
Opening and closing
load current |
XS-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
XS-15/100(200) |
15 |
||||||
PD-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
PD-15/100(200) |
15 |
||||||
(H)RW3-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW3-12/100(200) |
12 |
||||||
(H)RW4-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW4-12/100(200) |
12 |
||||||
(H)RW7-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW7-12/100(200) |
12 |
||||||
(H)RW10-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW10-12/100(200) |
12 |
||||||
(H)RW10-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW10-12F/100(200) |
12 |
||||||
(H)RW11-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
! |
(H)RW11-12/100(200) |
12 |
||||||
(H)RW11-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW11-12F/100(200) |
12 |
||||||
(H)RW12-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
45 |
30 |
105 |
/ |
(H)RW12-12/100(200) |
12 |
||||||
(H)RW12-15/100(200) |
15 |
||||||
(H)PRWG1-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)PRWG1-12F/100(200) |
12 |
||||||
(H)RW33-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW33-15/100(200) |
15 |
||||||
(H)RW5-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)RW10-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)PRWG2-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |