Polymeric Lightning Protection with Custom Voltage Surge Solutions

Product Details
Customization: Available
Type: Power Source Arrester
Structure: Zinc Oxide Arrester
Still deciding? Get samples of $ !
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

OEM Services
The supplier provides OEM services for popular brands
Quality Assurance
The supplier provides quality assurance
Private Mold
The supplier has private mold
Product Certification
The supplier's products already have relevant certification qualifications, including:
CE
to see all verified strength labels (20)
  • Polymeric Lightning Protection with Custom Voltage Surge Solutions
  • Polymeric Lightning Protection with Custom Voltage Surge Solutions
  • Polymeric Lightning Protection with Custom Voltage Surge Solutions
  • Polymeric Lightning Protection with Custom Voltage Surge Solutions
  • Polymeric Lightning Protection with Custom Voltage Surge Solutions
  • Polymeric Lightning Protection with Custom Voltage Surge Solutions
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Certifications
  • Company Profile
Overview

Basic Info.

Model NO.
YH series
Installation
According to Customer Requirements
Application
AC/DC System/Power Plants/Substation
Size
According to Customer Requirements
Operation Voltage
3 - 36kv
Shape
According to Customer Requirements
Material
ZnO
Certification
ROHS, ISO9001, CCC
Brand
Chbeb
Customizable
OEM/According to Customer Requirements
Voltage Customizable
30kv 33kv 36kv
Transport Package
Pallet
Trademark
CHBEB
Origin
China
HS Code
8535400000
Production Capacity
50000 Pieces/Quarter

Product Description

Product Description

Introducing the state-of-the-art Zinc Oxide Arrester from Beierbian Group Co., Ltd—an extraordinary breakthrough in lightning protection technology, specifically designed for 10kV power distribution systems. This cutting-edge device is a pinnacle of innovation, expertly crafted with a zinc oxide valve column. It is enhanced by the precision placement of upper and lower electrodes, all flawlessly encapsulated in premium silicone rubber. This sophisticated construction presents unmatched features:

  1. Discover the ground-breaking design that masterfully resolves the sealing challenges historically faced by arrester systems. Through the elegant integration of the core and jacket into a seamless, unified structure, it meticulously eliminates any potential cavities that could lead to damaging internal breathing issues. This ingenious engineering triumphs over complex technical obstacles, preventing moisture ingress within internal components, thereby ensuring superior performance and enhanced reliability for optimal protection.
  2. Featuring a robust core with impressive prowess to withstand internal overvoltage, this arrester exemplifies exceptional engineering. It boasts remarkable resistance to aging, ensuring consistent performance and steadfast protection year after year. Users are assured of its long-lasting reliability and effectiveness, making it a trusted choice for enduring safety.

With a specially engineered valve plate and optimized core parameters, this advanced device confidently tackles challenges such as arc grounding, PT resonance, and various operational overvoltages. It operates with unparalleled reliability, consistently performing under normal line voltage and enduring 2.5 to 3 times power frequency overvoltage. Its voltage withstand duration not only meets but exceeds international standards by 1 to 3 orders of magnitude, delivering unmatched safety and exceptional operational longevity, setting new benchmarks for protection and assurance.
Polymeric Lightning Protection with Custom Voltage Surge Solutions

Detailed Photos

Polymeric Lightning Protection with Custom Voltage Surge Solutions

Polymeric Lightning Protection with Custom Voltage Surge Solutions
Polymeric Lightning Protection with Custom Voltage Surge Solutions
Polymeric Lightning Protection with Custom Voltage Surge Solutions
Polymeric Lightning Protection with Custom Voltage Surge Solutions
Polymeric Lightning Protection with Custom Voltage Surge Solutions
Polymeric Lightning Protection with Custom Voltage Surge Solutions

Product Parameters

Main Characteristics Of Jacket Materials And Product Usage Environment:

Item

Unit

Norm

Shore Hardness A

/

60

Tensile Strength

mpa

≥35

Breaking Elongation

%

≥250

Oxygen Index

/

45

Resistivity

Ω.m

≥1×1013

Breakdown Strength

MV/m

≥25

Tracking

kV

4.5

Durability

Not less than 20 years

Working Environment:

Meticulously crafted for flawless functionality, the Polymeric Lightning Protection system excels both indoors and outdoors;

Innovatively engineered to ensure seamless operation at altitudes reaching an impressive 3000 meters;

Constructed to endure a vast spectrum of temperatures, ranging from a stark -40°C to a warm +60°C, adapting effortlessly to extreme conditions;

Expertly designed to harmonize with power supply frequencies that range from a steady 48Hz to a dynamic 62Hz, ensuring compatibility and efficiency;

Guarantees power frequency voltage between terminals stays within optimal limits, offering enduring and reliable performance;

Engineered to withstand seismic activities up to 8 degrees, maintaining robustness and reliability during earthquakes;

Purposefully designed to resist fierce outdoor wind speeds up to an impressive 35 meters per second, ensuring stability in high winds;

Note:

If your conditions exceed these parameters, our expert team is on hand to provide customized solutions tailored to your needs.

Main Technical Parameters

Model

Nominal Voltage

(rms)

Rated Voltage OArrester

(rms)

Continuous Operating Voltage

(rms)

DC 1mA reference voltage
kV not less than

The residual voltage under nominal discharge current
kV (Crest) not greater than

Steep wave impact residual voltage
kV (Crest) not greater than

2ms square wave flow capacity
A

Operation Place

YH5WS-3.8/17

3

3.8

2.0

7.5

17.0

19.6

100

 

Distribution Type

YH5WS-5/15

3

5

4.0

7.5

15.0

17.3

150

YH5WS-7.6/30

6

7.6

4.0

15.0

15.0

34.5

100

YH5WS-10/30

6

10

8.0

15.0

30.0

34.6

150

YH5WS-12.7/50

10

12.7

10

26.0

50.0

57.5

100

YH5WS-16.5/50

10

16.5

12.7

26.0

50.0

57.5

100

YH5WS-17/50

10

17

13.6

26.0

50.0

57.5

150

YH5WS-17/45

10

17

13.6

25.0

45.0

/

250

YH10WS-17/45

10

17

13.6

25.0

45.0

/

400

YH5WZ-5/13.5

3

5

4.0

7.2

13.5

15.5

200

Power Station Type

YH5WZ-7.6/27

6

7.6

4.0

14.4

27.0

31.0

150

YH5WZ-10/27

6

10

8.0

14.4

27.0

31.0

200

YH5WZ-42/134

35

42

23.4

73

134

154

150

YH5WZ-12.7/45

10

12.7

6.6

24.0

45.0

51.8

150

YH5WZ-16.5/45

10

16.5

13.2

24.0

45.0

51.8

150

YH5WZ-17/45

10

17

13.6

24.0

45.0

51.8

200

YH5WZ-51/134

35

51

40.8

73.0

134

154

400

YH10WZ-17/45

10

17

13.6

24.0

45.0

51.8

200

YH10WZ-51/134

35

51

40.8

73.0

134

154

400

YH5WR-5/13.5

3

5

4.0

7.2

13.5

/

400

Capacitive Type

YH5WR-7.6/27

6

7.6

4.0

13.8

27.0

/

400

YH5WR-10/27

6

10

8.0

14.4

27.0

/

400

YH5WR-12.7/45

10

12.7

6.6

23.0

45.0

/

400

YH5WR 17/45

10

17

13.6

24.0

45.0

/

400

YH5WX-51/134

35

51

40.8

73

134.0

154

400

Line type

YH1.5W-30/80

35

30

24

44

80.0

/

600

Neutral Type

Note: Featuring a durable, resilient Polymeric construction for unrivaled longevity.

Model

Nominal Voltage

(rms)

Rated Voltage OArrester

(rms)

Continuous Operating Voltage

(rms)

DC 1mA Reference Voltage
kV Not Less Than

The Residual Voltage Under Nominal Discharge Current
kV (Crest)
Not Greater Than

Steep Wave Impact Residual Voltage
kV (Crest)
Not Greater Than

2ms Square Wave Flow Capacity
A

Operation Place

Y5WS-5/15

3

5

4.0

7.5

15.0

17.3

150

Distribution Type

Y5WS-7.6/30

6

7.6

4.0

15.0

15.0

34.5

100

Y5WS-10/30

6

10

8.0

15.0

30.0

34.6

150

Y5WS-12.7/50

10

12.7

10

26.0

50.0

57.5

100

Y5WS-16.5/50

10

16.5

12.7

26.0

50.0

57.5

100

Y5WS-17/50

10

17

13.6

26.0

50.0

57.5

150

Y5WZ-5/13.5

3

5

4.0

7.2

13.5

15.5

200

Power Station Type

Y5WZ-7.6/27

6

7.6

4.0

14.4

27.0

31.0

150

Y5WZ-10/27

6

10

8.0

14.4

27.0

31.0

200

Y5WZ-42/134

35

42

23.4

73

134

154

150

Y5WZ-12.7/45

10

12.7

6.6

24.0

45.0

51.8

150

Y5WZ-16.5/45

10

16.5

13.2

24.0

45.0

51.8

150

Y5WZ-17/45

10

17

13.6

24.0

45.0

51.8

200

Y5WZ-51/134

35

51

40.8

73.0

134

154

400

Y5WR-5/13.5

3

5

4.0

7.2

13.5

/

400

Capacitive Type

Y5WR-7.6/27

6

7.6

4.0

13.8

27.0

/

400

Y5WR-10/27

6

10

8.0

14.4

27.0

/

400

Y5WR-12.7/45

10

12.7

6.6

23.0

45.0

/

400

Y5WR-17/45

10

17

13.6

24.0

45.0

/

400

Y1.5W-0.28/1.3

0.22

0.28

0.24

0.6

1.3

/

75

Low Voltage

Y1.5W-0.5/2.6

0.38

0.5

0.24

1.2

2.6

/

75

Note:Porcelain

Model

 

Nominal Voltage
(Valid values)

 

Rated Voltage Of Arrester
(Valid values)

 

The Wave Front

Steepness Of The Shock Discharge

 

DC 1mA Reference Voltage

kV Not Less Than

 

1.2/50 Impulse Discharge Voltage

Not Greater Than

 

Wavefront Impulse

Discharge Voltage

 

kV Not Greater Than

The Residual Voltage Under Nominal Discharge

Current 8/20μs

 

kV Not Greater Than

 

2000μs Square

Wave Flow Capacity

 

4/10μs Impulse

Current Capacity

Y5CS-7.6/27

6

7.6

63

16

35

43.8

27

75

25

Y5CZ-7.6/24

6

7.6

63

16

30

37.5

24

150

40

Y5CS-12.7/45

10

12.7

106

26

50

62.5

45

75

25

Y5CS-12.7/41

10

12.7

106

26

45

56.5

41

200

40

Y5CZ-42/124

35

42.0

343

82

134

168

124

200

40

Note: Incorporates advanced Porcelain Series Gap specifications for enhanced performance and reliability.

Installation

(1) Prior to installation, verify the nameplate to ensure the arrester's system rated voltage aligns perfectly with the system voltage at the site;

(2) Offers installation versatility with suspension or vertical options. Ensure, for vertical installations, that the arrester is not used as a load-bearing insulator;

(3) Carefully optimize lead wire length to maintain protection efficiency and reduce stress on the equipment.

Test

  • lTo boost operational reliability, conduct preventive tests every 4-5 years, focusing on measuring U1mA at both terminals of the DC 1mA arrester.
  • lPrior to installation, confirm that the U1mA voltage is at least 97% of the original factory value and meticulously document this data for precision.
  • lDuring preventive maintenance, it is essential to ensure the U1mA voltage remains above 26kV to maintain optimal performance.
  • lNote: Minimize harmonic components in the DC power supply during tests, as poor waveforms can result in low U1mA readings.
  • lOur state-of-the-art 10kV synthetic insulated zinc oxide arrester for power distribution has impressively passed rigorous lab tests, demonstrating consistent functionality under outdoor line voltage for 15 months. These tests affirm the superior quality of the jacket, the structural reliability of the arrester, and the unwavering stability of its core. Supported by annual performance data from 2,000 units, this product assures unmatched protection, drastically reduced failure rates, and a maintenance-free experience throughout its lifecycle.Polymeric Lightning Protection with Custom Voltage Surge Solutions
Certifications

Polymeric Lightning Protection with Custom Voltage Surge Solutions

Company Profile

Polymeric Lightning Protection with Custom Voltage Surge Solutions

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier