High Voltage AC Disconnect Switch Load Break Isolator Outdoor

Product Details
Customization: Available
Type: 10kv/12kv/15kv
Structure: According to Customer Requirements
Still deciding? Get samples of US$ 140/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

OEM Services
The supplier provides OEM services for popular brands
Quality Assurance
The supplier provides quality assurance
Private Mold
The supplier has private mold
Product Certification
The supplier's products already have relevant certification qualifications, including:
CE
to see all verified strength labels (20)
  • High Voltage AC Disconnect Switch Load Break Isolator Outdoor
  • High Voltage AC Disconnect Switch Load Break Isolator Outdoor
  • High Voltage AC Disconnect Switch Load Break Isolator Outdoor
  • High Voltage AC Disconnect Switch Load Break Isolator Outdoor
  • High Voltage AC Disconnect Switch Load Break Isolator Outdoor
  • High Voltage AC Disconnect Switch Load Break Isolator Outdoor
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Certifications
Overview

Basic Info.

Model NO.
(H)GWBEB
Installation
Outdoor High-voltage
Operation
Manual/Electric/Pneumatic/Hydraulic
Grounding Mode
According to Customer Requirements
Movement Mode
According to Customer Requirements
Number of Poles
According to Customer Requirements
Grounding
According to Customer Requirements
Series
Two
Run
According to Customer Requirements
Switching Mode
According to Customer Requirements
Common Model
Gw9
Structure of Operating
According to Customer Requirements
Certification
ISO, RoHS, CE
Brand
Chbeb
Customizable
OEM/According to Customer Requirements
Transport Package
Standard Shipping Packing
Specification
45*55*38mm
Trademark
CHBEB
Origin
China
HS Code
853530900
Production Capacity
5000 PCS/Quarter

Product Description

High Voltage AC Disconnect Switch Load Break Isolator Outdoor
Product Description

(H)GWBEB type outdoor high-voltage isolation switch, also known as an isolation disconnect switch, is meticulously engineered for seamless operation on 10(12, 15, 24)kV high voltage power transmission and distribution lines. This versatile switch facilitates the seamless opening and closing of single-phase or three-phase circuits, ensuring continuity even when voltage is present, but without a load.

This switch is crafted for single-phase use within three-phase line systems, boasting a simple yet robust structure that ensures cost-efficiency and user-friendly operation. The available rated currents span 200, 400, 600, 800, 1000, to 1250 amps, accommodating various demands. With a base, post insulators, conductive elements, and a mechanical section, each phase employs a gate knife configuration for circuit engagement. The gate knife features two conductive blades, flanked by external compression springs on each side. These springs' adjustable height ensures the optimal contact pressure for the switch's gate knife. The switch is adeptly maneuvered using an insulated hook stick, equipped with a self-locking mechanism for secure operations.

Working Environment:

Maximum installation altitude is 1000 meters;

Ambient temperature parameters: maximum should not exceed +40°C; minimum should not dip below -30°C;

Outdoor wind speeds must remain at or below 35 meters/second;

Seismic activity should not surpass an intensity of 8 degrees; the installation area must be free from frequent, severe vibrations.

Installation sites must be devoid of gases, chemical deposits, salt mist, dust, dirt, or any other explosive or corrosive mediums that could significantly impact the switch's insulation and conductivity.

Note:

SHOULD THE ABOVE NORMAL USE CONDITIONS BE EXCEEDED, USERS ARE ENCOURAGED TO ENGAGE IN NEGOTIATIONS WITH THE COMPANY.

Installation, Use and Adjustment

Pre-installation work

  1. Meticulously remove dust and dirt from all components, ensuring the insulating porcelain bottle's surface is thoroughly wiped clean.
  2. Carefully scrub the wiring surface of the ground screw to ensure optimal connectivity.
  3. Apply a protective layer of industrial Vaseline to rotating parts and contact areas for smooth operation.
  4. Inspect the contact surface and adjust the compression spring's height to ensure the contact pressure aligns with Table II specifications.
  5. This switch is exclusively designed for hoisting applications and is intended for use in tandem with the transformer on a power line.
  6. The rated current for this switch ranges from 200-400 amperes, typically utilizing three mounting holes. For 600-1000A applications, three mounting holes are also employed.

Conduct an annual inspection of the following switch components:
Thoroughly clean dirt from conductive components, contact surfaces, and the insulating porcelain bottle's outer layer.

Examine all parts for potential damage, with particular attention to the insulating porcelain bottle for any cracks or damage.

Ensure the conductive part's contact surface maintains optimal condition.


High Voltage AC Disconnect Switch Load Break Isolator Outdoor

Detailed Photos

High Voltage AC Disconnect Switch Load Break Isolator Outdoor
High Voltage AC Disconnect Switch Load Break Isolator Outdoor
High Voltage AC Disconnect Switch Load Break Isolator Outdoor
High Voltage AC Disconnect Switch Load Break Isolator Outdoor


High Voltage AC Disconnect Switch Load Break Isolator Outdoor
High Voltage AC Disconnect Switch Load Break Isolator Outdoor

High Voltage AC Disconnect Switch Load Break Isolator Outdoor
High Voltage AC Disconnect Switch Load Break Isolator Outdoor
High Voltage AC Disconnect Switch Load Break Isolator Outdoor
High Voltage AC Disconnect Switch Load Break Isolator Outdoor
High Voltage AC Disconnect Switch Load Break Isolator Outdoor
High Voltage AC Disconnect Switch Load Break Isolator Outdoor
High Voltage AC Disconnect Switch Load Break Isolator Outdoor
High Voltage AC Disconnect Switch Load Break Isolator Outdoor
High Voltage AC Disconnect Switch Load Break Isolator Outdoor
High Voltage AC Disconnect Switch Load Break Isolator Outdoor
High Voltage AC Disconnect Switch Load Break Isolator Outdoor
High Voltage AC Disconnect Switch Load Break Isolator Outdoor

Product Parameters

The main technical parameters

Table I

Model

Rated voltage
kV

 

Rated current
A

kA

 

10 seconds thermal stable current
kA

peak

Valid values

 

(H)GW

 

10

12

15

200

5

9

5

400

21

15

10

600

35

25

14

630

35

25

14

800

35

25

14

1000

50

35

20

Contact force parameters

Table II

Model

Rated current(A)

contact pressure(kgf)

(H)GW

5

9

21

15

35

25

35

25

35

25

50

35

Certifications

High Voltage AC Disconnect Switch Load Break Isolator OutdoorHigh Voltage AC Disconnect Switch Load Break Isolator Outdoor

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier