Customizable High Bearing Surge Arrester for Enhanced Voltage Protection

Product Details
Customization: Available
Type: Power Source Arrester
Structure: Zinc Oxide Arrester
Still deciding? Get samples of US$ 35/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

OEM Services
The supplier provides OEM services for popular brands
Quality Assurance
The supplier provides quality assurance
Private Mold
The supplier has private mold
Product Certification
The supplier's products already have relevant certification qualifications, including:
CE
to see all verified strength labels (20)
  • Customizable High Bearing Surge Arrester for Enhanced Voltage Protection
  • Customizable High Bearing Surge Arrester for Enhanced Voltage Protection
  • Customizable High Bearing Surge Arrester for Enhanced Voltage Protection
  • Customizable High Bearing Surge Arrester for Enhanced Voltage Protection
  • Customizable High Bearing Surge Arrester for Enhanced Voltage Protection
  • Customizable High Bearing Surge Arrester for Enhanced Voltage Protection
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Certifications
  • Company Profile
Overview

Basic Info.

Model NO.
YH series
Installation
According to Customer Requirements
Application
AC/DC System/Power Plants/Substation
Size
According to Customer Requirements
Operation Voltage
3 - 36kv
Shape
According to Customer Requirements
Material
ZnO
Certification
ROHS, ISO9001, CCC
Brand
Chbeb
Customizable
OEM/According to Customer Requirements
Voltage Customizable
30kv 33kv 36kv
Transport Package
Pallet
Trademark
CHBEB
Origin
China
HS Code
8535400000
Production Capacity
50000 Pieces/Quarter

Product Description

Product Description

Introducing the Zinc Oxide Arrester from Beierbian Group Co., Ltd - a revolutionary and fully sealed marvel in lightning protection, meticulously designed for 10kV power distribution systems. This state-of-the-art device is ingeniously crafted using a zinc oxide valve column, harmoniously integrated with upper and lower electrodes, all flawlessly encapsulated in silicone rubber, offering unmatched and unparalleled characteristics:

  1. This pioneering design expertly addresses and resolves the sealing challenges traditionally encountered in arresters. By ingeniously merging the core and jacket into a unified, compact structure, it eliminates any cavities that might cause internal breathing issues. Thus, it deftly overcomes the technical hurdles associated with preventing moisture ingress in internal components, ensuring a superbly reliable performance.
  2. With a robust core engineered to withstand formidable internal overvoltage, this arrester exemplifies exceptional aging resistance. This ensures continuous, high-level performance and steadfast protection, delivering reliability you can depend on year after year.

Employing a specially engineered valve plate combined with optimized core parameters, this device assures that the core can withstand challenges like arc grounding, PT resonance, and various operational overvoltages. It operates with unrivaled reliability under line voltage, even enduring 2.5 to 3 times power frequency overvoltage. Its voltage withstand duration far exceeds international standards by 1 to 3 orders of magnitude, promising unparalleled safety and operational longevity.
Customizable High Bearing Surge Arrester for Enhanced Voltage Protection

Detailed Photos

Customizable High Bearing Surge Arrester for Enhanced Voltage Protection

Customizable High Bearing Surge Arrester for Enhanced Voltage Protection
Customizable High Bearing Surge Arrester for Enhanced Voltage Protection
Customizable High Bearing Surge Arrester for Enhanced Voltage Protection
Customizable High Bearing Surge Arrester for Enhanced Voltage Protection
Customizable High Bearing Surge Arrester for Enhanced Voltage Protection
Customizable High Bearing Surge Arrester for Enhanced Voltage Protection

Product Parameters

Main Characteristics Of Jacket Materials And Product Usage Environment:

Item

Unit

Norm

Shore Hardness A

/

60

Tensile Strength

mpa

≥35

Breaking Elongation

%

≥250

Oxygen Index

/

45

Resistivity

Ω.m

≥1×1013

Breakdown Strength

MV/m

≥25

Tracking

kV

4.5

Durability

Not less than 20 years

Working Environment:

Specially crafted to ensure flawless functionality in both indoor and outdoor settings;

Effortlessly operational at elevations reaching a breathtaking 3000m;

Adept at handling ambient temperatures from a crisp -40C to a warm +60C;

Designed to seamlessly integrate with power supply frequencies stretching from a steady 48Hz to a versatile 62Hz;

Guarantees that power frequency voltage between terminals stays within ideal limits, ensuring longevity and performance.

Built to withstand seismic events with intensity levels up to 8 degrees.

Meticulously engineered to defy outdoor wind forces up to 35 meters/second;

Note:

For situations where operational conditions exceed normal parameters, our team is ready to offer bespoke solutions tailored to your needs.

Main technical parameters

Model

Nominal Voltage

(rms)

Rated Voltage OArrester

(rms)

Continuous Operating Voltage

(rms)

DC 1mA reference voltage
kV not less than

The residual voltage under nominal discharge current
kV (Crest) not greater than

Steep wave impact residual voltage
kV (Crest) not greater than

2ms square wave flow capacity
A

Operation Place

YH5WS-3.8/17

3

3.8

2.0

7.5

17.0

19.6

100

 

Distribution Type

YH5WS-5/15

3

5

4.0

7.5

15.0

17.3

150

YH5WS-7.6/30

6

7.6

4.0

15.0

15.0

34.5

100

YH5WS-10/30

6

10

8.0

15.0

30.0

34.6

150

YH5WS-12.7/50

10

12.7

10

26.0

50.0

57.5

100

YH5WS-16.5/50

10

16.5

12.7

26.0

50.0

57.5

100

YH5WS-17/50

10

17

13.6

26.0

50.0

57.5

150

YH5WS-17/45

10

17

13.6

25.0

45.0

/

250

YH10WS-17/45

10

17

13.6

25.0

45.0

/

400

YH5WZ-5/13.5

3

5

4.0

7.2

13.5

15.5

200

Power Station Type

YH5WZ-7.6/27

6

7.6

4.0

14.4

27.0

31.0

150

YH5WZ-10/27

6

10

8.0

14.4

27.0

31.0

200

YH5WZ-42/134

35

42

23.4

73

134

154

150

YH5WZ-12.7/45

10

12.7

6.6

24.0

45.0

51.8

150

YH5WZ-16.5/45

10

16.5

13.2

24.0

45.0

51.8

150

YH5WZ-17/45

10

17

13.6

24.0

45.0

51.8

200

YH5WZ-51/134

35

51

40.8

73.0

134

154

400

YH10WZ-17/45

10

17

13.6

24.0

45.0

51.8

200

YH10WZ-51/134

35

51

40.8

73.0

134

154

400

YH5WR-5/13.5

3

5

4.0

7.2

13.5

/

400

Capacitive Type

YH5WR-7.6/27

6

7.6

4.0

13.8

27.0

/

400

YH5WR-10/27

6

10

8.0

14.4

27.0

/

400

YH5WR-12.7/45

10

12.7

6.6

23.0

45.0

/

400

YH5WR 17/45

10

17

13.6

24.0

45.0

/

400

YH5WX-51/134

35

51

40.8

73

134.0

154

400

Line type

YH1.5W-30/80

35

30

24

44

80.0

/

600

Neutral Type

Note: Crafted with a durable Polymeric structure

Model

Nominal Voltage

(rms)

Rated Voltage OArrester

(rms)

Continuous Operating Voltage

(rms)

DC 1mA Reference Voltage
kV Not Less Than

The Residual Voltage Under Nominal Discharge Current
kV (Crest)
Not Greater Than

Steep Wave Impact Residual Voltage
kV (Crest)
Not Greater Than

2ms Square Wave Flow Capacity
A

Operation Place

Y5WS-5/15

3

5

4.0

7.5

15.0

17.3

150

Distribution Type

Y5WS-7.6/30

6

7.6

4.0

15.0

15.0

34.5

100

Y5WS-10/30

6

10

8.0

15.0

30.0

34.6

150

Y5WS-12.7/50

10

12.7

10

26.0

50.0

57.5

100

Y5WS-16.5/50

10

16.5

12.7

26.0

50.0

57.5

100

Y5WS-17/50

10

17

13.6

26.0

50.0

57.5

150

Y5WZ-5/13.5

3

5

4.0

7.2

13.5

15.5

200

Power Station Type

Y5WZ-7.6/27

6

7.6

4.0

14.4

27.0

31.0

150

Y5WZ-10/27

6

10

8.0

14.4

27.0

31.0

200

Y5WZ-42/134

35

42

23.4

73

134

154

150

Y5WZ-12.7/45

10

12.7

6.6

24.0

45.0

51.8

150

Y5WZ-16.5/45

10

16.5

13.2

24.0

45.0

51.8

150

Y5WZ-17/45

10

17

13.6

24.0

45.0

51.8

200

Y5WZ-51/134

35

51

40.8

73.0

134

154

400

Y5WR-5/13.5

3

5

4.0

7.2

13.5

/

400

Capacitive Type

Y5WR-7.6/27

6

7.6

4.0

13.8

27.0

/

400

Y5WR-10/27

6

10

8.0

14.4

27.0

/

400

Y5WR-12.7/45

10

12.7

6.6

23.0

45.0

/

400

Y5WR-17/45

10

17

13.6

24.0

45.0

/

400

Y1.5W-0.28/1.3

0.22

0.28

0.24

0.6

1.3

/

75

Low Voltage

Y1.5W-0.5/2.6

0.38

0.5

0.24

1.2

2.6

/

75

Note:Porcelain

Model

 

Nominal Voltage
(Valid values)

 

Rated Voltage Of Arrester
(Valid values)

 

The Wave Front

Steepness Of The Shock Discharge

 

DC 1mA Reference Voltage

kV Not Less Than

 

1.2/50 Impulse Discharge Voltage

Not Greater Than

 

Wavefront Impulse

Discharge Voltage

 

kV Not Greater Than

The Residual Voltage Under Nominal Discharge

Current 8/20μs

 

kV Not Greater Than

 

2000μs Square

Wave Flow Capacity

 

4/10μs Impulse

Current Capacity

Y5CS-7.6/27

6

7.6

63

16

35

43.8

27

75

25

Y5CZ-7.6/24

6

7.6

63

16

30

37.5

24

150

40

Y5CS-12.7/45

10

12.7

106

26

50

62.5

45

75

25

Y5CS-12.7/41

10

12.7

106

26

45

56.5

41

200

40

Y5CZ-42/124

35

42.0

343

82

134

168

124

200

40

Note: Equipped with Porcelain Series Gap specification

Installation

(1) Before proceeding with the installation, double-check the nameplate to confirm the arrester’s system rated voltage matches the system voltage at the installation site;

(2) Provides versatile installation options, including suspension or vertical arrangement. It is crucial that vertical installations do not utilize the arrester as a load-supporting insulator;

(3) Ensure optimal lead wire length to maintain protection efficiency while preventing undue strain on the equipment.

Test

  • lFor enhanced operational reliability, we recommend preventive tests every 4-5 years. Focus should be on measuring U1mA across both terminals of the DC 1mA arrester.
  • lBefore installation, confirm the U1mA voltage is at least 97% of the factory's original value and meticulously record this information.
  • lDuring preventive maintenance, it's imperative the U1mA voltage remains no less than 26kV.
  • lNote: To ensure accurate readings, minimize harmonic components in the DC power supply during tests. Poor waveforms can lead to decreased U1mA measurements.
  • lThe newly launched 10kV synthetic insulated zinc oxide arrester for power distribution has triumphantly passed stringent laboratory assessments, showcasing consistent performance under outdoor line voltage for an impressive 15 months. Results affirm the jacket’s superior quality, the arrester’s structural reliability, and its robust core stability. Supported by annual data from 2,000 units, this product offers exceptional protection, minimizes failure rates, and promises a maintenance-free lifespan.Customizable High Bearing Surge Arrester for Enhanced Voltage Protection
Certifications

Customizable High Bearing Surge Arrester for Enhanced Voltage Protection

Company Profile

Customizable High Bearing Surge Arrester for Enhanced Voltage Protection

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier