Tailored Polymeric Surge Arrester with Customizable Voltage Specifications

Product Details
Customization: Available
Type: Power Source Arrester
Structure: Zinc Oxide Arrester
Still deciding? Get samples of US$ 35/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

OEM Services
The supplier provides OEM services for popular brands
Quality Assurance
The supplier provides quality assurance
Private Mold
The supplier has private mold
Product Certification
The supplier's products already have relevant certification qualifications, including:
CE
to see all verified strength labels (20)
  • Tailored Polymeric Surge Arrester with Customizable Voltage Specifications
  • Tailored Polymeric Surge Arrester with Customizable Voltage Specifications
  • Tailored Polymeric Surge Arrester with Customizable Voltage Specifications
  • Tailored Polymeric Surge Arrester with Customizable Voltage Specifications
  • Tailored Polymeric Surge Arrester with Customizable Voltage Specifications
  • Tailored Polymeric Surge Arrester with Customizable Voltage Specifications
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Certifications
  • Company Profile
Overview

Basic Info.

Model NO.
YH series
Installation
According to Customer Requirements
Application
AC/DC System/Power Plants/Substation
Size
According to Customer Requirements
Operation Voltage
3 - 36kv
Shape
According to Customer Requirements
Material
ZnO
Certification
ROHS, ISO9001, CCC
Brand
Chbeb
Customizable
OEM/According to Customer Requirements
Voltage Customizable
30kv 33kv 36kv
Transport Package
Pallet
Trademark
CHBEB
Origin
China
HS Code
8535400000
Production Capacity
50000 Pieces/Quarter

Product Description

Product Description

Introducing the Zinc Oxide Arrester from Beierbian Group Co., Ltd—a groundbreaking, state-of-the-art, fully sealed marvel of lightning protection designed for 10kV power distribution systems. This cutting-edge innovation is meticulously engineered using a zinc oxide valve column, seamlessly integrated with upper and lower electrodes, all expertly encapsulated in high-quality silicone rubber. Its extraordinary features set new standards in lightning protection:

  1. This pioneering design expertly tackles and resolves the sealing challenges that have historically plagued arresters. By ingeniously integrating the core and jacket into a single, unified structure, it eliminates any potential cavities that could lead to internal breathing issues. This sophisticated solution brilliantly overcomes the technical obstacles associated with preventing moisture ingress into internal components, ensuring long-lasting reliability and superior performance.
  2. With a robust core engineered to endure significant internal overvoltage, this arrester presents exemplary aging resistance, ensuring long-term performance excellence and unwavering protection over the years. Its durability and resilience make it an indispensable component in safeguarding electrical systems from the ravages of time and usage.

Employing a specially designed valve plate combined with optimized core parameters, this remarkable device guarantees that the core can tackle challenges such as arc grounding, PT resonance, and an array of operational overvoltages. It consistently delivers unmatched reliability under line voltage conditions, enduring 2.5 to 3 times the power frequency overvoltage effortlessly. Impressively, its voltage withstand duration exceeds international standards by 1 to 3 orders of magnitude, ensuring unrivaled safety and exceptional operational longevity.
Tailored Polymeric Surge Arrester with Customizable Voltage Specifications

Detailed Photos

Tailored Polymeric Surge Arrester with Customizable Voltage Specifications

Tailored Polymeric Surge Arrester with Customizable Voltage Specifications
Tailored Polymeric Surge Arrester with Customizable Voltage Specifications
Tailored Polymeric Surge Arrester with Customizable Voltage Specifications
Tailored Polymeric Surge Arrester with Customizable Voltage Specifications
Tailored Polymeric Surge Arrester with Customizable Voltage Specifications
Tailored Polymeric Surge Arrester with Customizable Voltage Specifications

Product Parameters

Main Characteristics Of Jacket Materials And Product Usage Environment:

Item

Unit

Norm

Shore Hardness A

/

60

Tensile Strength

mpa

≥35

Breaking Elongation

%

≥250

Oxygen Index

/

45

Resistivity

Ω.m

≥1×1013

Breakdown Strength

MV/m

≥25

Tracking

kV

4.5

Durability

Not less than 20 years

Working Environment:

Expertly crafted for flawless performance in both indoor and outdoor settings;

Excellently operational at impressive altitudes reaching up to 3000 meters;

Skillfully endures vast temperature variations from a crisp -40°C to a warm +60°C;

Seamlessly handles power frequencies ranging from a calm 48Hz to an energetic 62Hz;

Maintains power frequency voltage between terminals within ideal limits for extended usability.

Designed to withstand seismic forces with magnitudes up to 8 degrees.

Engineered to bravely resist wind speeds soaring up to 35 meters per second;

Note:

For conditions exceeding these specified operational parameters, our expert team is ready to discuss bespoke solutions tailored to your unique needs.

Main technical parameters

Model

Nominal Voltage

(rms)

Rated Voltage OArrester

(rms)

Continuous Operating Voltage

(rms)

DC 1mA reference voltage
kV not less than

The residual voltage under nominal discharge current
kV (Crest) not greater than

Steep wave impact residual voltage
kV (Crest) not greater than

2ms square wave flow capacity
A

Operation Place

YH5WS-3.8/17

3

3.8

2.0

7.5

17.0

19.6

100

 

Distribution Type

YH5WS-5/15

3

5

4.0

7.5

15.0

17.3

150

YH5WS-7.6/30

6

7.6

4.0

15.0

15.0

34.5

100

YH5WS-10/30

6

10

8.0

15.0

30.0

34.6

150

YH5WS-12.7/50

10

12.7

10

26.0

50.0

57.5

100

YH5WS-16.5/50

10

16.5

12.7

26.0

50.0

57.5

100

YH5WS-17/50

10

17

13.6

26.0

50.0

57.5

150

YH5WS-17/45

10

17

13.6

25.0

45.0

/

250

YH10WS-17/45

10

17

13.6

25.0

45.0

/

400

YH5WZ-5/13.5

3

5

4.0

7.2

13.5

15.5

200

Power Station Type

YH5WZ-7.6/27

6

7.6

4.0

14.4

27.0

31.0

150

YH5WZ-10/27

6

10

8.0

14.4

27.0

31.0

200

YH5WZ-42/134

35

42

23.4

73

134

154

150

YH5WZ-12.7/45

10

12.7

6.6

24.0

45.0

51.8

150

YH5WZ-16.5/45

10

16.5

13.2

24.0

45.0

51.8

150

YH5WZ-17/45

10

17

13.6

24.0

45.0

51.8

200

YH5WZ-51/134

35

51

40.8

73.0

134

154

400

YH10WZ-17/45

10

17

13.6

24.0

45.0

51.8

200

YH10WZ-51/134

35

51

40.8

73.0

134

154

400

YH5WR-5/13.5

3

5

4.0

7.2

13.5

/

400

Capacitive Type

YH5WR-7.6/27

6

7.6

4.0

13.8

27.0

/

400

YH5WR-10/27

6

10

8.0

14.4

27.0

/

400

YH5WR-12.7/45

10

12.7

6.6

23.0

45.0

/

400

YH5WR 17/45

10

17

13.6

24.0

45.0

/

400

YH5WX-51/134

35

51

40.8

73

134.0

154

400

Line type

YH1.5W-30/80

35

30

24

44

80.0

/

600

Neutral Type

Note: Featuring a durable Polymeric construction

Model

Nominal Voltage

(rms)

Rated Voltage OArrester

(rms)

Continuous Operating Voltage

(rms)

DC 1mA Reference Voltage
kV Not Less Than

The Residual Voltage Under Nominal Discharge Current
kV (Crest)
Not Greater Than

Steep Wave Impact Residual Voltage
kV (Crest)
Not Greater Than

2ms Square Wave Flow Capacity
A

Operation Place

Y5WS-5/15

3

5

4.0

7.5

15.0

17.3

150

Distribution Type

Y5WS-7.6/30

6

7.6

4.0

15.0

15.0

34.5

100

Y5WS-10/30

6

10

8.0

15.0

30.0

34.6

150

Y5WS-12.7/50

10

12.7

10

26.0

50.0

57.5

100

Y5WS-16.5/50

10

16.5

12.7

26.0

50.0

57.5

100

Y5WS-17/50

10

17

13.6

26.0

50.0

57.5

150

Y5WZ-5/13.5

3

5

4.0

7.2

13.5

15.5

200

Power Station Type

Y5WZ-7.6/27

6

7.6

4.0

14.4

27.0

31.0

150

Y5WZ-10/27

6

10

8.0

14.4

27.0

31.0

200

Y5WZ-42/134

35

42

23.4

73

134

154

150

Y5WZ-12.7/45

10

12.7

6.6

24.0

45.0

51.8

150

Y5WZ-16.5/45

10

16.5

13.2

24.0

45.0

51.8

150

Y5WZ-17/45

10

17

13.6

24.0

45.0

51.8

200

Y5WZ-51/134

35

51

40.8

73.0

134

154

400

Y5WR-5/13.5

3

5

4.0

7.2

13.5

/

400

Capacitive Type

Y5WR-7.6/27

6

7.6

4.0

13.8

27.0

/

400

Y5WR-10/27

6

10

8.0

14.4

27.0

/

400

Y5WR-12.7/45

10

12.7

6.6

23.0

45.0

/

400

Y5WR-17/45

10

17

13.6

24.0

45.0

/

400

Y1.5W-0.28/1.3

0.22

0.28

0.24

0.6

1.3

/

75

Low Voltage

Y1.5W-0.5/2.6

0.38

0.5

0.24

1.2

2.6

/

75

Note:Porcelain

Model

 

Nominal Voltage
(Valid values)

 

Rated Voltage Of Arrester
(Valid values)

 

The Wave Front

Steepness Of The Shock Discharge

 

DC 1mA Reference Voltage

kV Not Less Than

 

1.2/50 Impulse Discharge Voltage

Not Greater Than

 

Wavefront Impulse

Discharge Voltage

 

kV Not Greater Than

The Residual Voltage Under Nominal Discharge

Current 8/20μs

 

kV Not Greater Than

 

2000μs Square

Wave Flow Capacity

 

4/10μs Impulse

Current Capacity

Y5CS-7.6/27

6

7.6

63

16

35

43.8

27

75

25

Y5CZ-7.6/24

6

7.6

63

16

30

37.5

24

150

40

Y5CS-12.7/45

10

12.7

106

26

50

62.5

45

75

25

Y5CS-12.7/41

10

12.7

106

26

45

56.5

41

200

40

Y5CZ-42/124

35

42.0

343

82

134

168

124

200

40

Note: Incorporates Porcelain Series Gap specification for enhanced security

Installation

(1) Before installation, confirm the arrester's nameplate matches the system's rated voltage at the installation point;

(2) Versatile installation options available: suspension or vertical. For vertical installation, ensure the arrester isn't used as a load-bearing insulator;

(3) Optimize lead wire length to uphold protection efficiency while minimizing equipment stress.

Test

  • lTo enhance operational reliability, conduct preventive tests every 4-5 years with an emphasis on measuring U1mA at both terminals of the DC 1mA arrester.
  • lPrior to installation, ensure the U1mA voltage reaches at least 97% of its original factory value. This data should be meticulously recorded.
  • lDuring preventive maintenance, verify that the U1mA voltage remains above 26kV to ensure optimal performance.
  • lNote: Ensure minimal harmonic distortion in the DC power supply during testing, as poor waveforms may lead to inaccurate, low U1mA readings.
  • lThe innovative 10kV synthetic insulated zinc oxide arrester for power distribution has passed stringent laboratory testing, showcasing reliable functionality under outdoor line voltage for 15 consecutive months. Tests confirmed: superior jacket quality, dependable arrester structure, and strong core integrity. Combining results from 2,000 units' annual performance data, the product guarantees exceptional protection, significantly reduced failure rates, and maintenance-free operation across its lifespan.Tailored Polymeric Surge Arrester with Customizable Voltage Specifications
Certifications

Tailored Polymeric Surge Arrester with Customizable Voltage Specifications

Company Profile

Tailored Polymeric Surge Arrester with Customizable Voltage Specifications

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier