Medium Voltage Outdoor Isolation Switch Load Break Disconnector 10/12kv

Product Details
Customization: Available
Type: 10kv/12kv/15kv
Structure: According to Customer Requirements
Still deciding? Get samples of US$ 140/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

OEM Services
The supplier provides OEM services for popular brands
Quality Assurance
The supplier provides quality assurance
Private Mold
The supplier has private mold
Product Certification
The supplier's products already have relevant certification qualifications, including:
CE
to see all verified strength labels (20)
  • Medium Voltage Outdoor Isolation Switch Load Break Disconnector 10/12kv
  • Medium Voltage Outdoor Isolation Switch Load Break Disconnector 10/12kv
  • Medium Voltage Outdoor Isolation Switch Load Break Disconnector 10/12kv
  • Medium Voltage Outdoor Isolation Switch Load Break Disconnector 10/12kv
  • Medium Voltage Outdoor Isolation Switch Load Break Disconnector 10/12kv
  • Medium Voltage Outdoor Isolation Switch Load Break Disconnector 10/12kv
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Certifications
Overview

Basic Info.

Model NO.
(H)GWBEB
Installation
Outdoor High-voltage
Operation
Manual/Electric/Pneumatic/Hydraulic
Grounding Mode
According to Customer Requirements
Movement Mode
According to Customer Requirements
Number of Poles
According to Customer Requirements
Grounding
According to Customer Requirements
Series
Two
Run
According to Customer Requirements
Switching Mode
According to Customer Requirements
Common Model
Gw9
Structure of Operating
According to Customer Requirements
Certification
ISO, RoHS, CE
Brand
Chbeb
Customizable
OEM/According to Customer Requirements
Transport Package
Standard Shipping Packing
Specification
45*55*38mm
Trademark
CHBEB
Origin
China
HS Code
853530900
Production Capacity
5000 PCS/Quarter

Product Description

Medium Voltage Outdoor Isolation Switch Load Break Disconnector 10/12kv
Product Description

Introducing the versatile (H)GWBEB type outdoor high-voltage isolation switch, also popularly known as an isolation disconnect switch. This product is meticulously engineered to facilitate the seamless opening and closing of single-phase or three-phase circuits on 10(12, 15, 24)kV high-voltage power transmission and distribution lines. It efficiently operates without load but with voltage present, making it indispensable for modern power systems.

This remarkable switch, designed for single-phase applications within three-phase line systems, is celebrated for its straightforward structure, affordability, and user-friendly nature. Available in a variety of rated currents: 200, 400, 600, 800, 1000, and 1250 amps, it is composed of a robust base, reliable post insulators, conductive components, and a precise mechanical section. Utilizing a gate knife structure for smooth circuit operation, each phase's gate knife features dual conductive blades with strategic external compression springs on both sides, ensuring optimal contact pressure through adjustable spring height. Operated with an insulated hook stick, it incorporates a fail-safe self-locking device, enhancing its safety and convenience.

Working Environment:

Designed for altitudes of up to 1000 meters;

Can withstand ambient temperatures ranging from a maximum of +40°C to a minimum of -30°C;

Built to endure outdoor wind speeds of up to 35 meters per second;

Capable of withstanding seismic intensities of up to 8 degrees; ensure the installation site is free from frequent severe vibrations.

The installation site must be free from gases, chemical deposits, salt mist, dust, dirt, or other explosive or corrosive substances that could compromise the switch's insulation and conductive performance.

Note:

WHEN NORMAL USE CONDITIONS ARE EXCEEDED, USERS ARE ENCOURAGED TO ENGAGE WITH THE COMPANY FOR CUSTOM SOLUTIONS.

Installation, Use and Adjustment

Pre-installation work

  1. Thoroughly remove any dust and dirt from all components, and gently clean the insulating porcelain bottle's surface for optimal performance.
  2. Ensure a pristine wiring surface by carefully scrubbing the ground screw.
  3. Apply a protective layer of industrial Vaseline to all rotating parts and contact areas to ensure smooth operation and longevity.
  4. Inspect the contact surface and adjust the compression spring height to align with the standards specified in Table II for precise contact pressure.
  5. Exclusively designed for hoisting applications, this switch is intended to be used in conjunction with a transformer on the line, showcasing its specialized utility.
  6. For rated currents of 200-400 amperes, typically three mounting holes are utilized, while 600-1000A applications also rely on three mounting holes for secure installation.

Conduct an annual check on the following switch components:
Diligently clean dirt from all conductive parts, contact surfaces, and insulating porcelain bottle surfaces to maintain peak operational efficiency.

Carefully inspect all components for any signs of damage, with particular attention to the insulating porcelain bottle for cracks or damage.

Verify the integrity of the contact surface on the conductive parts to ensure optimal performance.


Medium Voltage Outdoor Isolation Switch Load Break Disconnector 10/12kv

Detailed Photos

Medium Voltage Outdoor Isolation Switch Load Break Disconnector 10/12kv
Medium Voltage Outdoor Isolation Switch Load Break Disconnector 10/12kv
Medium Voltage Outdoor Isolation Switch Load Break Disconnector 10/12kv
Medium Voltage Outdoor Isolation Switch Load Break Disconnector 10/12kv


Medium Voltage Outdoor Isolation Switch Load Break Disconnector 10/12kv
Medium Voltage Outdoor Isolation Switch Load Break Disconnector 10/12kv

Medium Voltage Outdoor Isolation Switch Load Break Disconnector 10/12kv
Medium Voltage Outdoor Isolation Switch Load Break Disconnector 10/12kv
Medium Voltage Outdoor Isolation Switch Load Break Disconnector 10/12kv
Medium Voltage Outdoor Isolation Switch Load Break Disconnector 10/12kv
Medium Voltage Outdoor Isolation Switch Load Break Disconnector 10/12kv
Medium Voltage Outdoor Isolation Switch Load Break Disconnector 10/12kv
Medium Voltage Outdoor Isolation Switch Load Break Disconnector 10/12kv
Medium Voltage Outdoor Isolation Switch Load Break Disconnector 10/12kv
Medium Voltage Outdoor Isolation Switch Load Break Disconnector 10/12kv
Medium Voltage Outdoor Isolation Switch Load Break Disconnector 10/12kv
Medium Voltage Outdoor Isolation Switch Load Break Disconnector 10/12kv
Medium Voltage Outdoor Isolation Switch Load Break Disconnector 10/12kv

Product Parameters

The main technical parameters

Table I

Model

Rated voltage
kV

 

Rated current
A

kA

 

10 seconds thermal stable current
kA

peak

Valid values

 

(H)GW

 

10

12

15

200

5

9

5

400

21

15

10

600

35

25

14

630

35

25

14

800

35

25

14

1000

50

35

20

Contact force parameters

Table II

Model

Rated current(A)

contact pressure(kgf)

(H)GW

5

9

21

15

35

25

35

25

35

25

50

35

Certifications

Medium Voltage Outdoor Isolation Switch Load Break Disconnector 10/12kvMedium Voltage Outdoor Isolation Switch Load Break Disconnector 10/12kv

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier