Customization: | Available |
---|---|
Breaking Capacity: | 12kv/24kv/40.5kv |
Type: | Current Fuse |
Still deciding? Get samples of US$ 30/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
(H) RW(F) series outdoor high voltage AC drop fuse (hereinafter referred to as "fuse") is a pinnacle of engineering designed specifically for the demanding needs of outdoor overhead distribution systems operating at a rated frequency of 50Hz with a rated voltage of 10kV (12/15/35/40.5). This fuse serves as an indispensable protective element for circuits and electrical equipment, safeguarding against the perils of overloads or short circuit faults within a power system. During regular operations, the fuse remains securely connected in series within the power line, ensuring resilience through its tensioned state and locked movable joint. In the event of a line failure, the fault current triggers the fuse to blow, releasing the movable joint, and swiftly dropping the fuse tube to sever the circuit. This instantaneous action provides essential safety protection, facilitating the maintenance of lines and equipment with ease. Enhanced with elastic contact and an arc extinguishing cover, the load type fuse surpasses ordinary types, adeptly managing the opening and closing of load currents within the power system.
The fuse is manufactured in strict adherence to prominent technical standards, including GB / T 15166.3 - 2008 for high voltage AC fuses - Part 3: injection fuses, and DL / T 640 - 1997 for outdoor AC high voltage drop tested fuses and fuse links ordering technical conditions. These standards ensure reliability and performance excellence.
Working Environment:
Ambient temperature: Encompasses extreme conditions, ranging from a chilling -40°C to a balmy +40°C;
Relative humidity: Maintains a daily average of no more than 95%, with a monthly average capped at 90%;
Altitude: Suitable for installations where the altitude does not exceed 3000m;
Outdoor wind speed: Designed to withstand wind speeds not exceeding 34 meters/second;
Installation site: Must be devoid of fire, explosion hazards, corrosive chemical gases, and should be situated in well-ventilated environments.
Note: Should your installation site exceed the specified normal conditions, our team welcomes you to engage in a dialogue with us for a bespoke solution tailored to your unique requirements.
Technical parameters
Note: We pride ourselves on customization and are fully equipped to supply products that align with specific user requirements, ensuring tailored solutions for diverse applications.
Model |
Voltage |
Current |
Rated maximum
breaking current |
1min power frequency dry withstand
voltage |
1min power frequency wet withstand
voltage |
Rated lightning impulse withstand
voltage |
Opening and closing
load current |
XS-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
XS-15/100(200) |
15 |
||||||
PD-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
PD-15/100(200) |
15 |
||||||
(H)RW3-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW3-12/100(200) |
12 |
||||||
(H)RW4-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW4-12/100(200) |
12 |
||||||
(H)RW7-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW7-12/100(200) |
12 |
||||||
(H)RW10-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW10-12/100(200) |
12 |
||||||
(H)RW10-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW10-12F/100(200) |
12 |
||||||
(H)RW11-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
! |
(H)RW11-12/100(200) |
12 |
||||||
(H)RW11-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW11-12F/100(200) |
12 |
||||||
(H)RW12-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
45 |
30 |
105 |
/ |
(H)RW12-12/100(200) |
12 |
||||||
(H)RW12-15/100(200) |
15 |
||||||
(H)PRWG1-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)PRWG1-12F/100(200) |
12 |
||||||
(H)RW33-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW33-15/100(200) |
15 |
||||||
(H)RW5-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)RW10-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)PRWG2-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |