Reliable Outdoor Load Break Isolator Switch for High Voltage Systems

Product Details
Customization: Available
Type: 10kv/12kv/15kv
Structure: According to Customer Requirements
Still deciding? Get samples of US$ 140/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

OEM Services
The supplier provides OEM services for popular brands
Quality Assurance
The supplier provides quality assurance
Private Mold
The supplier has private mold
Product Certification
The supplier's products already have relevant certification qualifications, including:
CE
to see all verified strength labels (20)
  • Reliable Outdoor Load Break Isolator Switch for High Voltage Systems
  • Reliable Outdoor Load Break Isolator Switch for High Voltage Systems
  • Reliable Outdoor Load Break Isolator Switch for High Voltage Systems
  • Reliable Outdoor Load Break Isolator Switch for High Voltage Systems
  • Reliable Outdoor Load Break Isolator Switch for High Voltage Systems
  • Reliable Outdoor Load Break Isolator Switch for High Voltage Systems
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Certifications
Overview

Basic Info.

Model NO.
(H)GWBEB
Installation
Outdoor High-voltage
Operation
Manual/Electric/Pneumatic/Hydraulic
Grounding Mode
According to Customer Requirements
Movement Mode
According to Customer Requirements
Number of Poles
According to Customer Requirements
Grounding
According to Customer Requirements
Series
Two
Run
According to Customer Requirements
Switching Mode
According to Customer Requirements
Common Model
Gw9
Structure of Operating
According to Customer Requirements
Certification
ISO, RoHS, CE
Brand
Chbeb
Customizable
OEM/According to Customer Requirements
Transport Package
Standard Shipping Packing
Specification
45*55*38mm
Trademark
CHBEB
Origin
China
HS Code
853530900
Production Capacity
5000 PCS/Quarter

Product Description

Reliable Outdoor Load Break Isolator Switch for High Voltage Systems
Product Description

Introducing the (H)GWBEB type outdoor high-voltage isolation switch, commonly referred to as an isolation disconnect switch. This essential component is expertly crafted for integration into 10(12, 15, 24)kV high voltage power transmission and distribution lines, enabling the seamless opening and closing of single-phase or three-phase circuits under voltage conditions without load.

Designed specifically for single-phase applications within three-phase line systems, this switch is renowned for its straightforward design, cost-effectiveness, and user-friendly operation. The available rated currents are diverse, ranging from 200, 400, 600, 800, 1000, to 1250 amps. The switch's construction includes a sturdy base, post insulators, conductive components, and a mechanical section. A sophisticated gate knife structure facilitates the precise opening and closing of circuits, with each phase's gate knife comprising dual conductive blades complemented by external compression springs on either side. By adjusting the spring height, optimal contact pressure is achieved, ensuring flawless performance of the switch's gate knife. Utilizing an insulated hook stick, the opening and closing operations are executed with ease, and the switch is equipped with a self-locking mechanism for added safety.

Working Environment:

Suited for altitudes not exceeding 1000 meters, this switch operates flawlessly within its designated range, ensuring reliable performance in diverse terrains.

The ambient temperature conditions for optimal operation are defined as a maximum not exceeding +40°C and a minimum not dipping below -30°C, catering to varying climatic conditions.

It withstands outdoor wind speeds up to a maximum of 35 meters per second, ensuring robustness and stability even in challenging weather conditions.

This switch is designed to function effectively in seismic zones with intensities not exceeding 8 degrees, as it is engineered to be resilient against frequent severe vibrations.

The installation site should be devoid of gases, chemical deposits, salt mist, dust, dirt, or any other explosive or corrosive substances that could severely impact the switch's insulation and conductivity, ensuring its longevity and reliability.

Note:

WHEN OPERATING CONDITIONS EXCEED THE PARAMETERS SPECIFIED ABOVE, USERS ARE ENCOURAGED TO CONSULT WITH OUR COMPANY FOR SPECIAL ARRANGEMENTS.

Installation, Use, and Adjustment

Pre-installation Work

  1. Meticulously remove any dust and dirt from all components, and delicately clean the surface of the insulating porcelain bottle to ensure optimal performance.
  2. Thoroughly scrub the wiring surface of the ground screw to maintain a pristine contact area.
  3. To ensure smooth operation, apply a generous layer of industrial Vaseline to all rotating parts and contact areas.
  4. Inspect the contact surfaces and adjust the height of the compression spring to ensure the contact pressure aligns with the specifications outlined in Table II, guaranteeing the switch's efficient functionality.
  5. This switch is exclusively designed for hoisting operations and should be used in conjunction with the transformer along the line.
  6. For rated currents of 200-400 ampere hours, typically three mounting holes are sufficient, while 600-1000A applications also utilize three mounting holes for secure installation.

Conduct the following annual maintenance checks to ensure the switch's longevity and reliability:
Meticulously remove any accumulated dirt from conductive parts, contact surfaces, and the exterior of insulating porcelain bottles to maintain optimal performance.

Inspect all components for any signs of damage, with a particular focus on checking the insulating porcelain bottle for any damage or cracks that could affect performance.

Verify that the contact surface of each conductive part remains in excellent condition, ensuring seamless conductivity.


Reliable Outdoor Load Break Isolator Switch for High Voltage Systems

Detailed Photos

Reliable Outdoor Load Break Isolator Switch for High Voltage Systems
Reliable Outdoor Load Break Isolator Switch for High Voltage Systems
Reliable Outdoor Load Break Isolator Switch for High Voltage Systems
Reliable Outdoor Load Break Isolator Switch for High Voltage Systems


Reliable Outdoor Load Break Isolator Switch for High Voltage Systems
Reliable Outdoor Load Break Isolator Switch for High Voltage Systems

Reliable Outdoor Load Break Isolator Switch for High Voltage Systems
Reliable Outdoor Load Break Isolator Switch for High Voltage Systems
Reliable Outdoor Load Break Isolator Switch for High Voltage Systems
Reliable Outdoor Load Break Isolator Switch for High Voltage Systems
Reliable Outdoor Load Break Isolator Switch for High Voltage Systems
Reliable Outdoor Load Break Isolator Switch for High Voltage Systems
Reliable Outdoor Load Break Isolator Switch for High Voltage Systems
Reliable Outdoor Load Break Isolator Switch for High Voltage Systems
Reliable Outdoor Load Break Isolator Switch for High Voltage Systems
Reliable Outdoor Load Break Isolator Switch for High Voltage Systems
Reliable Outdoor Load Break Isolator Switch for High Voltage Systems
Reliable Outdoor Load Break Isolator Switch for High Voltage Systems

Product Parameters

The main technical parameters

Table I

Model

Rated voltage
kV

 

Rated current
A

kA

 

10 seconds thermal stable current
kA

peak

Valid values

 

(H)GW

 

10

12

15

200

5

9

5

400

21

15

10

600

35

25

14

630

35

25

14

800

35

25

14

1000

50

35

20

Contact force parameters

Table II

Model

Rated current(A)

contact pressure(kgf)

(H)GW

5

9

21

15

35

25

35

25

35

25

50

35

Certifications

Reliable Outdoor Load Break Isolator Switch for High Voltage SystemsReliable Outdoor Load Break Isolator Switch for High Voltage Systems

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier