Customization: | Available |
---|---|
Breaking Capacity: | 12kv/24kv/40.5kv |
Type: | Current Fuse |
Still deciding? Get samples of US$ 30/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
(H) RW(F) series outdoor high voltage AC drop fuse, commonly known as the 'fuse', stands as the optimal protective solution for outdoor overhead distribution systems. Designed for environments with a rated frequency of 50Hz and rated voltage options of 10kV (12/15/35/40.5), this fuse is your first line of defense against overloads or short circuits in power systems. Under normal conditions, it remains securely locked in series with the power line. In the event of a fault, the fault current triggers the fuse to blow, releasing the movable joint and dropping the fuse tube swiftly to sever the circuit. This action ensures superior safety and protection during maintenance activities. Enhanced with elastic contact and an arc extinguishing cover, this load type fuse is engineered to efficiently open and close the load current within the power system, setting a benchmark in operational excellence.
The fuse is meticulously crafted to align with stringent technical standards including GB / T 15166.3 - 2008, which covers high voltage AC fuses - Part 3: injection fuses, and DL / T 640 - 1997 specifications for outdoor AC high voltage drop tested fuses and fuse links ordering technical conditions. These certifications assure unmatched reliability and compliance in every aspect of its operation.
Working Environment:
Ambient temperature: Ranges from -40°C to +40°C, ensuring robust performance across extreme climates.
Relative humidity: The daily average should not exceed 95%, with the monthly average held below 90%, maintaining operational integrity.
Altitude: Suitable for installations at elevations up to 3000 meters, maintaining efficiency across varied terrains.
Outdoor wind speed should not surpass 34 meters per second, ensuring stability in windy conditions.
Installation site: Must be free from fire, explosion hazards, and chemical corrosive gases. Ensure a well-ventilated location for optimal performance.
Note: If your conditions exceed the standard parameters listed, we invite you to engage with our company for tailored solutions to meet your specific needs.
echnical parameters
Note: Our company is equipped to customize products in accordance with your specific requirements.
Model |
Voltage |
Current |
Rated maximum
breaking current |
1min power frequency dry withstand
voltage |
1min power frequency wet withstand
voltage |
Rated lightning impulse withstand
voltage |
Opening and closing
load current |
XS-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
XS-15/100(200) |
15 |
||||||
PD-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
PD-15/100(200) |
15 |
||||||
(H)RW3-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW3-12/100(200) |
12 |
||||||
(H)RW4-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW4-12/100(200) |
12 |
||||||
(H)RW7-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW7-12/100(200) |
12 |
||||||
(H)RW10-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW10-12/100(200) |
12 |
||||||
(H)RW10-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW10-12F/100(200) |
12 |
||||||
(H)RW11-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
! |
(H)RW11-12/100(200) |
12 |
||||||
(H)RW11-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW11-12F/100(200) |
12 |
||||||
(H)RW12-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
45 |
30 |
105 |
/ |
(H)RW12-12/100(200) |
12 |
||||||
(H)RW12-15/100(200) |
15 |
||||||
(H)PRWG1-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)PRWG1-12F/100(200) |
12 |
||||||
(H)RW33-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW33-15/100(200) |
15 |
||||||
(H)RW5-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)RW10-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)PRWG2-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |