Load Break Disconnector for Medium Voltage Outdoor Safety Solutions

Product Details
Customization: Available
Type: 10kv/12kv/15kv
Structure: According to Customer Requirements
Still deciding? Get samples of $ !
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

OEM Services
The supplier provides OEM services for popular brands
Quality Assurance
The supplier provides quality assurance
Private Mold
The supplier has private mold
Product Certification
The supplier's products already have relevant certification qualifications, including:
CE
to see all verified strength labels (20)
  • Load Break Disconnector for Medium Voltage Outdoor Safety Solutions
  • Load Break Disconnector for Medium Voltage Outdoor Safety Solutions
  • Load Break Disconnector for Medium Voltage Outdoor Safety Solutions
  • Load Break Disconnector for Medium Voltage Outdoor Safety Solutions
  • Load Break Disconnector for Medium Voltage Outdoor Safety Solutions
  • Load Break Disconnector for Medium Voltage Outdoor Safety Solutions
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Certifications
Overview

Basic Info.

Model NO.
(H)GWBEB
Installation
Outdoor High-voltage
Operation
Manual/Electric/Pneumatic/Hydraulic
Grounding Mode
According to Customer Requirements
Movement Mode
According to Customer Requirements
Number of Poles
According to Customer Requirements
Grounding
According to Customer Requirements
Series
Two
Run
According to Customer Requirements
Switching Mode
According to Customer Requirements
Common Model
Gw9
Structure of Operating
According to Customer Requirements
Certification
ISO, RoHS, CE
Brand
Chbeb
Customizable
OEM/According to Customer Requirements
Transport Package
Standard Shipping Packing
Specification
45*55*38mm
Trademark
CHBEB
Origin
China
HS Code
853530900
Production Capacity
5000 PCS/Quarter

Product Description

Load Break Disconnector for Medium Voltage Outdoor Safety Solutions
Product Description

Introducing the versatile and reliable (H)GWBEB type outdoor high-voltage isolation switch, commonly known as an isolation disconnect switch. This essential component is engineered specifically for 10(12, 15, 24)kV high voltage power transmission and distribution lines, adeptly managing the opening and closing of single-phase or three-phase circuits while maintaining voltage continuity. Experience seamless performance in voltage management with precision and safety.

The switch is a masterpiece of engineering, intended for single-phase implementation in three-phase line systems. Its salient features include a straightforward structure, economic feasibility, and user-friendly operation. With available rated currents of 200, 400, 600, 800, 1000, and 1250 amps, these switches embody flexibility and power. They are composed of a robust base, high-quality post insulators, conductive components, and a mechanical section designed for efficiency. The innovative gate knife structure facilitates reliable circuit management, comprising two conductive blades per phase, reinforced by external compression springs on both sides. Adjusting the spring height allows for optimal contact pressure, ensuring consistent performance. The switch is operated using a conveniently insulated hook stick, and features an integrated self-locking device for added security.

Working Environment:

Ideal for locations with an altitude not exceeding 1000 meters;

Designed to function seamlessly within an ambient temperature range: maximum not above +40°C and minimum not below -30°C;

Compatible with outdoor environments where wind speed does not exceed 35 meters per second;

Built to withstand seismic intensity not exceeding 8 degrees, ensuring durability in areas with minimal severe vibrations.

For optimal operation, the installation site should be free from gases, chemical deposits, salt mist, dust, dirt, or other explosive or corrosive substances that could compromise the switch's insulation and conductivity.

Note:

WHEN THE ABOVE NORMAL USE CONDITIONS ARE EXCEEDED, USERS ARE ENCOURAGED TO ENGAGE IN DISCUSSIONS WITH THE COMPANY TO EXPLORE CUSTOMIZED SOLUTIONS.

Installation, Use and Adjustment

Pre-installation work

  1. Ensure all parts are pristine by removing dust and debris, and meticulously cleaning the insulating porcelain bottle surfaces.
  2. Thoroughly scrub the ground screw wiring surface to ensure flawless conductivity.
  3. Apply a protective coat of industrial Vaseline to the rotating components and contact areas to maintain optimal functionality.
  4. Inspect the contact surfaces and meticulously adjust the compression spring height to ensure the contact pressure aligns with Table II's specifications.
  5. This switch is specifically crafted for hoisting applications and is adeptly used in conjunction with transformers along the line for maximum efficacy.
  6. The switch boasts a rated current spanning 200-400 amperes, typically necessitating three mounting holes. For 600-1000A, similarly, three mounting holes are utilized, ensuring stability and performance.

It is essential to conduct annual inspections of the following switch components:
Diligently remove any dirt from conductive parts, contact surfaces, and the insulating porcelain bottle surfaces to maintain performance integrity.

Inspect all components for potential damage, with an emphasis on identifying any damage or cracks in the insulating porcelain bottle.

Ensure the conductive part's contact surface remains in optimal condition.


Load Break Disconnector for Medium Voltage Outdoor Safety Solutions

Detailed Photos

Load Break Disconnector for Medium Voltage Outdoor Safety Solutions
Load Break Disconnector for Medium Voltage Outdoor Safety Solutions
Load Break Disconnector for Medium Voltage Outdoor Safety Solutions
Load Break Disconnector for Medium Voltage Outdoor Safety Solutions


Load Break Disconnector for Medium Voltage Outdoor Safety Solutions
Load Break Disconnector for Medium Voltage Outdoor Safety Solutions

Load Break Disconnector for Medium Voltage Outdoor Safety Solutions
Load Break Disconnector for Medium Voltage Outdoor Safety Solutions
Load Break Disconnector for Medium Voltage Outdoor Safety Solutions
Load Break Disconnector for Medium Voltage Outdoor Safety Solutions
Load Break Disconnector for Medium Voltage Outdoor Safety Solutions
Load Break Disconnector for Medium Voltage Outdoor Safety Solutions
Load Break Disconnector for Medium Voltage Outdoor Safety Solutions
Load Break Disconnector for Medium Voltage Outdoor Safety Solutions
Load Break Disconnector for Medium Voltage Outdoor Safety Solutions
Load Break Disconnector for Medium Voltage Outdoor Safety Solutions
Load Break Disconnector for Medium Voltage Outdoor Safety Solutions
Load Break Disconnector for Medium Voltage Outdoor Safety Solutions

Product Parameters

The main technical parameters

Table I

Model

Rated voltage
kV

 

Rated current
A

kA

 

10 seconds thermal stable current
kA

peak

Valid values

 

(H)GW

 

10

12

15

200

5

9

5

400

21

15

10

600

35

25

14

630

35

25

14

800

35

25

14

1000

50

35

20

Contact force parameters

Table II

Model

Rated current(A)

contact pressure(kgf)

(H)GW

5

9

21

15

35

25

35

25

35

25

50

35

Certifications

Load Break Disconnector for Medium Voltage Outdoor Safety SolutionsLoad Break Disconnector for Medium Voltage Outdoor Safety Solutions

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier