Customizable Zinc Oxide Lightning Protection Solutions for Voltage Control

Product Details
Customization: Available
Type: Power Source Arrester
Structure: Zinc Oxide Arrester
Still deciding? Get samples of $ !
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

OEM Services
The supplier provides OEM services for popular brands
Quality Assurance
The supplier provides quality assurance
Private Mold
The supplier has private mold
Product Certification
The supplier's products already have relevant certification qualifications, including:
CE
to see all verified strength labels (20)
  • Customizable Zinc Oxide Lightning Protection Solutions for Voltage Control
  • Customizable Zinc Oxide Lightning Protection Solutions for Voltage Control
  • Customizable Zinc Oxide Lightning Protection Solutions for Voltage Control
  • Customizable Zinc Oxide Lightning Protection Solutions for Voltage Control
  • Customizable Zinc Oxide Lightning Protection Solutions for Voltage Control
  • Customizable Zinc Oxide Lightning Protection Solutions for Voltage Control
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Certifications
  • Company Profile
Overview

Basic Info.

Model NO.
YH series
Installation
According to Customer Requirements
Application
AC/DC System/Power Plants/Substation
Size
According to Customer Requirements
Operation Voltage
3 - 36kv
Shape
According to Customer Requirements
Material
ZnO
Certification
ROHS, ISO9001, CCC
Brand
Chbeb
Customizable
OEM/According to Customer Requirements
Voltage Customizable
30kv 33kv 36kv
Transport Package
Pallet
Trademark
CHBEB
Origin
China
HS Code
8535400000
Production Capacity
50000 Pieces/Quarter

Product Description

Product Description

Introducing the Zinc Oxide Arrester crafted by Beierbian Group Co., Ltd—a groundbreaking, fully sealed marvel in the realm of lightning protection designed specifically for 10kV power distribution systems. This cutting-edge device features an ingeniously constructed zinc oxide valve column, harmoniously paired with upper and lower electrodes. Encapsulated in durable silicone rubber, this arrester provides exceptional reliability and unique characteristics, setting a new standard in lightning protection.

  1. This inventive design is a masterstroke in solving the perennial sealing challenges faced by traditional arresters. By merging the core and jacket into a unified, streamlined entity, it effectively eliminates cavities that could cause detrimental internal breathing issues. This smart integration triumphs over technical obstacles, particularly those related to preventing moisture ingress in the most sensitive internal components.
  2. Featuring a robust core engineered to withstand significant internal overvoltage, this arrester is the epitome of exceptional aging resistance. It guarantees long-lasting performance and steadfast protection, ensuring that your systems are shielded against the test of time and the elements.

Employing a specially designed valve plate along with meticulously optimized core parameters, this device assures that the core can resist complex challenges such as arc grounding, PT resonance, and a wide range of operational overvoltages. It operates with unparalleled dependability under line voltage and is resilient against 2.5 to 3 times power frequency overvoltage. Its voltage withstand duration not only meets but exceeds international standards by 1 to 3 orders of magnitude, delivering unmatched safety and exceptional operational longevity.
Customizable Zinc Oxide Lightning Protection Solutions for Voltage Control

Detailed Photos

Customizable Zinc Oxide Lightning Protection Solutions for Voltage Control

Customizable Zinc Oxide Lightning Protection Solutions for Voltage Control
Customizable Zinc Oxide Lightning Protection Solutions for Voltage Control
Customizable Zinc Oxide Lightning Protection Solutions for Voltage Control
Customizable Zinc Oxide Lightning Protection Solutions for Voltage Control
Customizable Zinc Oxide Lightning Protection Solutions for Voltage Control
Customizable Zinc Oxide Lightning Protection Solutions for Voltage Control

Product Parameters

Main Characteristics Of Jacket Materials And Product Usage Environment:

Item

Unit

Norm

Shore Hardness A

/

60

Tensile Strength

mpa

≥35

Breaking Elongation

%

≥250

Oxygen Index

/

45

Resistivity

Ω.m

≥1×1013

Breakdown Strength

MV/m

≥25

Tracking

kV

4.5

Durability

Not less than 20 years

Working Environment:

Meticulously crafted for flawless performance in both indoor and outdoor settings;

Designed to function seamlessly at grand altitudes reaching up to 3000 meters;

Built to thrive in a wide temperature spectrum from a brisk -40°C to a warm +60°C;

Harmonizes with power supply frequencies ranging from a consistent 48Hz to a vibrant 62Hz;

Maintains optimal power frequency voltage between terminals for sustained and reliable usage.

Capable of withstanding seismic activities with intensities up to 8 degrees.

Designed to defy outdoor wind speeds as high as 35 meters per second;

Note:

Should your operational conditions exceed these standard parameters, our team is ready to consult on custom solutions tailored to your specific needs.

Main Technical Parameters

Model

Nominal Voltage

(rms)

Rated Voltage OArrester

(rms)

Continuous Operating Voltage

(rms)

DC 1mA reference voltage
kV not less than

The residual voltage under nominal discharge current
kV (Crest) not greater than

Steep wave impact residual voltage
kV (Crest) not greater than

2ms square wave flow capacity
A

Operation Place

YH5WS-3.8/17

3

3.8

2.0

7.5

17.0

19.6

100

 

Distribution Type

YH5WS-5/15

3

5

4.0

7.5

15.0

17.3

150

YH5WS-7.6/30

6

7.6

4.0

15.0

15.0

34.5

100

YH5WS-10/30

6

10

8.0

15.0

30.0

34.6

150

YH5WS-12.7/50

10

12.7

10

26.0

50.0

57.5

100

YH5WS-16.5/50

10

16.5

12.7

26.0

50.0

57.5

100

YH5WS-17/50

10

17

13.6

26.0

50.0

57.5

150

YH5WS-17/45

10

17

13.6

25.0

45.0

/

250

YH10WS-17/45

10

17

13.6

25.0

45.0

/

400

YH5WZ-5/13.5

3

5

4.0

7.2

13.5

15.5

200

Power Station Type

YH5WZ-7.6/27

6

7.6

4.0

14.4

27.0

31.0

150

YH5WZ-10/27

6

10

8.0

14.4

27.0

31.0

200

YH5WZ-42/134

35

42

23.4

73

134

154

150

YH5WZ-12.7/45

10

12.7

6.6

24.0

45.0

51.8

150

YH5WZ-16.5/45

10

16.5

13.2

24.0

45.0

51.8

150

YH5WZ-17/45

10

17

13.6

24.0

45.0

51.8

200

YH5WZ-51/134

35

51

40.8

73.0

134

154

400

YH10WZ-17/45

10

17

13.6

24.0

45.0

51.8

200

YH10WZ-51/134

35

51

40.8

73.0

134

154

400

YH5WR-5/13.5

3

5

4.0

7.2

13.5

/

400

Capacitive Type

YH5WR-7.6/27

6

7.6

4.0

13.8

27.0

/

400

YH5WR-10/27

6

10

8.0

14.4

27.0

/

400

YH5WR-12.7/45

10

12.7

6.6

23.0

45.0

/

400

YH5WR 17/45

10

17

13.6

24.0

45.0

/

400

YH5WX-51/134

35

51

40.8

73

134.0

154

400

Line type

YH1.5W-30/80

35

30

24

44

80.0

/

600

Neutral Type

Note: Constructed with a durable Polymeric build for enhanced resilience

Model

Nominal Voltage

(rms)

Rated Voltage OArrester

(rms)

Continuous Operating Voltage

(rms)

DC 1mA Reference Voltage
kV Not Less Than

The Residual Voltage Under Nominal Discharge Current
kV (Crest)
Not Greater Than

Steep Wave Impact Residual Voltage
kV (Crest)
Not Greater Than

2ms Square Wave Flow Capacity
A

Operation Place

Y5WS-5/15

3

5

4.0

7.5

15.0

17.3

150

Distribution Type

Y5WS-7.6/30

6

7.6

4.0

15.0

15.0

34.5

100

Y5WS-10/30

6

10

8.0

15.0

30.0

34.6

150

Y5WS-12.7/50

10

12.7

10

26.0

50.0

57.5

100

Y5WS-16.5/50

10

16.5

12.7

26.0

50.0

57.5

100

Y5WS-17/50

10

17

13.6

26.0

50.0

57.5

150

Y5WZ-5/13.5

3

5

4.0

7.2

13.5

15.5

200

Power Station Type

Y5WZ-7.6/27

6

7.6

4.0

14.4

27.0

31.0

150

Y5WZ-10/27

6

10

8.0

14.4

27.0

31.0

200

Y5WZ-42/134

35

42

23.4

73

134

154

150

Y5WZ-12.7/45

10

12.7

6.6

24.0

45.0

51.8

150

Y5WZ-16.5/45

10

16.5

13.2

24.0

45.0

51.8

150

Y5WZ-17/45

10

17

13.6

24.0

45.0

51.8

200

Y5WZ-51/134

35

51

40.8

73.0

134

154

400

Y5WR-5/13.5

3

5

4.0

7.2

13.5

/

400

Capacitive Type

Y5WR-7.6/27

6

7.6

4.0

13.8

27.0

/

400

Y5WR-10/27

6

10

8.0

14.4

27.0

/

400

Y5WR-12.7/45

10

12.7

6.6

23.0

45.0

/

400

Y5WR-17/45

10

17

13.6

24.0

45.0

/

400

Y1.5W-0.28/1.3

0.22

0.28

0.24

0.6

1.3

/

75

Low Voltage

Y1.5W-0.5/2.6

0.38

0.5

0.24

1.2

2.6

/

75

Note:Porcelain

Model

 

Nominal Voltage
(Valid values)

 

Rated Voltage Of Arrester
(Valid values)

 

The Wave Front

Steepness Of The Shock Discharge

 

DC 1mA Reference Voltage

kV Not Less Than

 

1.2/50 Impulse Discharge Voltage

Not Greater Than

 

Wavefront Impulse

Discharge Voltage

 

kV Not Greater Than

The Residual Voltage Under Nominal Discharge

Current 8/20μs

 

kV Not Greater Than

 

2000μs Square

Wave Flow Capacity

 

4/10μs Impulse

Current Capacity

Y5CS-7.6/27

6

7.6

63

16

35

43.8

27

75

25

Y5CZ-7.6/24

6

7.6

63

16

30

37.5

24

150

40

Y5CS-12.7/45

10

12.7

106

26

50

62.5

45

75

25

Y5CS-12.7/41

10

12.7

106

26

45

56.5

41

200

40

Y5CZ-42/124

35

42.0

343

82

134

168

124

200

40

Note: Incorporates Porcelain Series Gap specification for superior performance

Installation

(1) Before commencing installation, check the nameplate to confirm that the arrester's system rated voltage is compatible with the system voltage at the planned site;

(2) Offers adaptable installation options, either suspension or vertical. For vertical installation, avoid using the arrester as a structural load-bearing insulator;

(3) Ensure that the lead wire length is optimized to maximize protection efficiency and minimize stress on equipment.

Test

  • l To boost operational reliability, conduct preventive testing every 4-5 years. Focus particularly on measuring U1mA across both terminals of the DC 1mA arrester.
  • l Prior to installation, confirm that the U1mA voltage is at least 97% of its original factory specification and properly document this information.
  • l During preventive checks, ensure that the U1mA voltage doesn't drop below 26kV.
  • l Note: Reduce harmonic components in the DC power supply during tests, as poor waveforms could lead to inaccurate low U1mA readings.
  • l Our latest 10kV synthetic insulated zinc oxide arrester for power distribution has successfully cleared exhaustive laboratory tests, proving consistent performance under outdoor line voltage over 15 months. The results underscore the jacket's outstanding quality, the arrester's structural reliability, and the core's robust stability. Supported by yearly performance data from 2,000 units, this product offers unmatched protection, significantly reduced failure rates, and promises maintenance-free operation throughout its lifecycle.Customizable Zinc Oxide Lightning Protection Solutions for Voltage Control
Certifications

Customizable Zinc Oxide Lightning Protection Solutions for Voltage Control

Company Profile

Customizable Zinc Oxide Lightning Protection Solutions for Voltage Control

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now