Custom High Voltage Outdoor Isolator Load Break Disconnect Switch – 10/12/15kv Power Distribution

Product Details
Customization: Available
Type: 10kv/12kv/15kv
Structure: According to Customer Requirements
Still deciding? Get samples of $ !
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW PayPal
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

OEM Services
The supplier provides OEM services for popular brands
Quality Assurance
The supplier provides quality assurance
Private Mold
The supplier has private mold
Product Certification
The supplier's products already have relevant certification qualifications, including:
CE
to see all verified strength labels (20)
  • Custom High Voltage Outdoor Isolator Load Break Disconnect Switch – 10/12/15kv Power Distribution
  • Custom High Voltage Outdoor Isolator Load Break Disconnect Switch – 10/12/15kv Power Distribution
  • Custom High Voltage Outdoor Isolator Load Break Disconnect Switch – 10/12/15kv Power Distribution
  • Custom High Voltage Outdoor Isolator Load Break Disconnect Switch – 10/12/15kv Power Distribution
  • Custom High Voltage Outdoor Isolator Load Break Disconnect Switch – 10/12/15kv Power Distribution
  • Custom High Voltage Outdoor Isolator Load Break Disconnect Switch – 10/12/15kv Power Distribution
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Certifications
Overview

Basic Info.

Model NO.
(H)GWBEB
Installation
Outdoor High-voltage
Operation
Manual/Electric/Pneumatic/Hydraulic
Grounding Mode
According to Customer Requirements
Movement Mode
According to Customer Requirements
Number of Poles
According to Customer Requirements
Grounding
According to Customer Requirements
Series
Two
Run
According to Customer Requirements
Switching Mode
According to Customer Requirements
Common Model
Gw9
Structure of Operating
According to Customer Requirements
Certification
ISO, RoHS, CE
Brand
Chbeb
Customizable
OEM/According to Customer Requirements
Transport Package
Standard Shipping Packing
Specification
45*55*38mm
Trademark
CHBEB
Origin
China
HS Code
853530900
Production Capacity
5000 PCS/Quarter

Packaging & Delivery

Package Size
45.00cm * 55.00cm * 38.00cm
Package Gross Weight
20.000kg

Product Description

Custom High Voltage Outdoor Isolator Load Break Disconnect Switch – 10/12/15kv Power Distribution
Product Description

(H)GWBEB type outdoor high-voltage isolation switch, also famed as the isolation disconnect switch, is ingeniously crafted for seamless operation on 10(12, 15, 24)kV high voltage power transmission and distribution lines. This sophisticated switch elegantly opens and closes single-phase or three-phase circuits without load, all while voltage is present, ensuring remarkable efficiency and precision.

This switch is meticulously designed for single-phase applications within three-phase line systems, boasting a simple yet highly effective structure, making it an excellent, cost-effective choice. Its ease of use is unparalleled. Available in a range of rated currents, including 200, 400, 600, 800, 1000, and 1250 amps, these switches are composed of a robust base, reliable post insulators, conductive parts, and a precise mechanical section. The innovative gate knife structure expertly facilitates circuit opening and closing, with each phase's gate knife comprising two conductive blades, secured with external compression springs on both sides. By adjusting the spring height, optimal contact pressure for the switch's gate knife is effortlessly achieved. The switch is operated with grace using an insulated hook stick for opening and closing actions and is enhanced with a self-locking device for added safety and reliability.

Working Environment:

Altitude should gracefully not exceed 1000 meters;

Ambient temperature: maximum delightfully not above +40°C; minimum charmingly not below -30°C;

Outdoor wind speed elegantly not exceeding 35 meters/second;

Seismic intensity harmoniously not exceeding 8 degrees; the installation site should ideally be free from frequent severe vibrations to ensure optimal performance.

The installation site should be devoid of gases, chemical deposits, salt mist, dust, dirt, or any other explosive or corrosive mediums that could significantly compromise the switch's insulation and conductivity.

Note:

WHEN THE ABOVE NORMAL USE CONDITIONS ARE EXCEEDED, USERS HAVE THE OPPORTUNITY TO ENGAGE IN NEGOTIATIONS WITH THE COMPANY FOR A TAILORED SOLUTION.

 

Installation, Use and Adjustment

Pre-installation work

  1. Meticulously remove dust and dirt from the components and gently wipe the surface of the insulating porcelain bottle for optimal cleanliness.
  2. Carefully scrub the wiring surface of the ground screw to ensure pristine connectivity.
  3. Generously apply a layer of industrial Vaseline to the rotating parts and contact areas for smooth performance and reduced friction.
  4. Diligently inspect the contact surface and adjust the height of the compression spring, ensuring the contact pressure aligns flawlessly with Table II specifications.
  5. This switch is exclusively designed for hoisting use and is seamlessly integrated with the transformer on the line for enhanced utility.
  6. The rated current of this switch varies between 200-400 ampere hours, typically utilizing three mounting holes, while 600-1000A also employs three mounting holes for secure installation.

Annually embark on a thorough check-up of the following switch components:
Meticulously remove any dirt from conductive parts, contact surfaces, and the surface of insulating porcelain bottles to maintain optimal conductivity.

Conduct a comprehensive inspection of all parts for any damage, with special emphasis on scrutinizing the insulating porcelain bottle for any signs of damage or cracks.

Ensure the contact surface of the conductive part remains in excellent condition to guarantee efficient performance.


Custom High Voltage Outdoor Isolator Load Break Disconnect Switch – 10/12/15kv Power Distribution

Detailed Photos

 

Custom High Voltage Outdoor Isolator Load Break Disconnect Switch – 10/12/15kv Power Distribution
Custom High Voltage Outdoor Isolator Load Break Disconnect Switch – 10/12/15kv Power Distribution
Custom High Voltage Outdoor Isolator Load Break Disconnect Switch – 10/12/15kv Power Distribution
Custom High Voltage Outdoor Isolator Load Break Disconnect Switch – 10/12/15kv Power Distribution


Custom High Voltage Outdoor Isolator Load Break Disconnect Switch – 10/12/15kv Power Distribution
Custom High Voltage Outdoor Isolator Load Break Disconnect Switch – 10/12/15kv Power Distribution

Custom High Voltage Outdoor Isolator Load Break Disconnect Switch – 10/12/15kv Power Distribution
Custom High Voltage Outdoor Isolator Load Break Disconnect Switch – 10/12/15kv Power Distribution
Custom High Voltage Outdoor Isolator Load Break Disconnect Switch – 10/12/15kv Power Distribution
Custom High Voltage Outdoor Isolator Load Break Disconnect Switch – 10/12/15kv Power Distribution
Custom High Voltage Outdoor Isolator Load Break Disconnect Switch – 10/12/15kv Power Distribution
Custom High Voltage Outdoor Isolator Load Break Disconnect Switch – 10/12/15kv Power Distribution
Custom High Voltage Outdoor Isolator Load Break Disconnect Switch – 10/12/15kv Power Distribution
Custom High Voltage Outdoor Isolator Load Break Disconnect Switch – 10/12/15kv Power Distribution
Custom High Voltage Outdoor Isolator Load Break Disconnect Switch – 10/12/15kv Power Distribution
Custom High Voltage Outdoor Isolator Load Break Disconnect Switch – 10/12/15kv Power Distribution
Custom High Voltage Outdoor Isolator Load Break Disconnect Switch – 10/12/15kv Power Distribution
Custom High Voltage Outdoor Isolator Load Break Disconnect Switch – 10/12/15kv Power Distribution

 

Product Parameters

The main technical parameters

Table I

Model

Rated voltage
kV

 

Rated current
A

kA

 

10 seconds thermal stable current
kA

peak

Valid values

 

(H)GW

 

10

12

15

200

5

9

5

400

21

15

10

600

35

25

14

630

35

25

14

800

35

25

14

1000

50

35

20

Contact force parameters

Table II

Model

Rated current(A)

contact pressure(kgf)

(H)GW

5

9

21

15

35

25

35

25

35

25

50

35

Certifications