Customization: | Available |
---|---|
Breaking Capacity: | 12kv/24kv/40.5kv |
Type: | Current Fuse |
Still deciding? Get samples of $ !
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
(H) RW(F) Series Outdoor High Voltage AC Drop Fuse (hereinafter referred to as "fuse") stands as a pinnacle of safety and reliability for outdoor overhead distribution systems with a rated frequency of 50Hz and rated voltages of 10kV (12/15/35/40.5). Designed to act as a crucial protective element for circuits and electrical equipment, this exceptional fuse safeguards against overloads and short circuit faults within power systems. Under normal operating conditions, the fuse is seamlessly connected in series along the power line, maintaining a tensioned state with a securely locked movable joint. In the event of a line fault, the fault current activates the fuse, releasing the movable joint, swiftly dropping the fuse tube, and effectively disconnecting the circuit. This precise mechanism offers invaluable safety protection for the maintenance of lines and equipment. Enhanced with elastic contact and an arc extinguishing cover, the load type fuse goes beyond ordinary types, adeptly handling the opening and closing of load currents in the power system.
Our fuse is meticulously crafted to comply with stringent technical standards, including GB / T 15166.3 - 2008 High Voltage AC Fuses - Part 3: Injection Fuses, and DL / T 640 - 1997 Outdoor AC High Voltage Drop Tested Fuses and Fuse Links Ordering Technical Conditions. These standards ensure top-tier performance and reliability.
Working Environment:
Ambient Temperature: Ranging from a frigid -40°C to a warm +40°C;
Relative Humidity: Daily average should not exceed 95%, with a monthly average not surpassing 90%;
Altitude: This product is designed for areas where the altitude does not exceed 3000m;
Outdoor Wind Speed: It can withstand wind speeds not exceeding 34 meters/second;
Installation Site: Ensure a location free from fire, explosion hazards, and chemical corrosive gases, while also being well-ventilated.
Note: For scenarios where standard operating conditions are surpassed, users are encouraged to engage in negotiations with the company for customized solutions.
Technical Parameters
Note: Our company is poised to provide tailored products to meet specific user requirements.
Model |
Voltage |
Current |
Rated maximum
breaking current |
1min power frequency dry withstand
voltage |
1min power frequency wet withstand
voltage |
Rated lightning impulse withstand
voltage |
Opening and closing
load current |
XS-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
XS-15/100(200) |
15 |
||||||
PD-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
PD-15/100(200) |
15 |
||||||
(H)RW3-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW3-12/100(200) |
12 |
||||||
(H)RW4-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW4-12/100(200) |
12 |
||||||
(H)RW7-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW7-12/100(200) |
12 |
||||||
(H)RW10-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW10-12/100(200) |
12 |
||||||
(H)RW10-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW10-12F/100(200) |
12 |
||||||
(H)RW11-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
! |
(H)RW11-12/100(200) |
12 |
||||||
(H)RW11-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW11-12F/100(200) |
12 |
||||||
(H)RW12-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
45 |
30 |
105 |
/ |
(H)RW12-12/100(200) |
12 |
||||||
(H)RW12-15/100(200) |
15 |
||||||
(H)PRWG1-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)PRWG1-12F/100(200) |
12 |
||||||
(H)RW33-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW33-15/100(200) |
15 |
||||||
(H)RW5-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)RW10-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)PRWG2-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |