Customization: | Available |
---|---|
Type: | High-voltage |
Structure: | Three-column Disconnector |
Still deciding? Get samples of US$ 800/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Introducing the ZW32-12 outdoor high voltage vacuum circuit breaker, the trusted 'circuit breaker' of choice for outdoor distribution needs. This exemplary switchgear is engineered for a 12kV rated voltage paired with a powerful three-phase AC of 50Hz. Exceptionally versatile, it seamlessly manages the interruption and connection of load, overload, and short circuit currents within the power grid. With its cutting-edge overload and short circuit protective abilities, it adeptly fulfills control and measurement needs while offering sophisticated remote control and monitoring features. This circuit breaker is indispensable in substations, industrial settings, and mining distribution systems, delivering superior control and operation, especially suited for frequent operation environments.
Structural features:
Crafted with exceptional precision, the circuit breaker is distinguished by its advanced three-phase pillar dry design;
Engineered with a fully enclosed structure, it offers outstanding sealing, exceptional moisture resistance, and anti-condensation properties, making it the prime choice for high-temperature and humid environments;
Utilizes cutting-edge vacuum arc extinguishing technology, providing remarkable insulation reliability;
Ensures impeccable opening and closing performance, guaranteeing safety with no risk of combustion or explosion;
Compact and lightweight, it requires zero maintenance and promises an exceptional lifespan;
Offers operational versatility with manual, electric, or remote control options;
The operating mechanism is expertly sealed at the base of the switch box, ensuring protection against outdoor environmental corrosion;
Boasts a novel, simplistic design with a restless mechanism, delivering reliable dynamic performance, a compact form, and an impressive service life of up to 10,000 cycles.
Main technical parameters:
No |
Name |
Unit |
Data |
|||
1 |
Rated voltage |
kV |
12 |
|||
2 |
Rated current |
A |
630 |
1250 |
||
3 |
Rated frequency |
Hz |
50 |
|||
4 |
Rated insulation level |
1min power frequency withstand voltage |
Dry test |
/ |
42/48(fracture) |
|
Wet test |
34 |
|||||
Secondary circuit to ground |
2 |
|||||
Lightning impulse withstand voltage (peak value) |
75/85(fracture) |
|||||
5 |
Rated short circuit making current (peak value) |
kA |
50 |
63 |
||
6 |
Rated short time withstand current |
kA |
20 |
25 |
||
7 |
Rated peak withstand current |
kA |
50 |
63 |
||
8 |
Breaking times of rated short circuit breaking current |
Times |
30 |
|||
9 |
Rated short circuit duration |
s |
4 |
|||
10 |
Rated operating voltage and rated voltage of auxiliary circuit |
V |
DC220,AC220 ,AC/DC220 |
|||
11 |
Rated operation sequence |
/ |
Off-0.3s-on-off-180s-on-off |
|||
12 |
Rated current of over current trip |
A |
5 |
|||
13 |
Mechanical life |
second |
10000 |
|||
14 |
Allowable wear accumulative thickness of moving and static contacts |
mm |
3 |
|||
15 |
Rated current of over current release |
A |
5 |
|||
16 |
Current ratio of current transformer |
/ |
200/5 400/5 600/5 |
|||
17 |
Contact opening distance |
mm |
9±1 |
|||
18 |
Contact overtravel |
mm |
2±0.5 |
|||
19 |
Average opening speed |
m/s |
1.2±0.3 |
|||
20 |
Average closing speed |
m/s |
0.6±0.2 |
|||
21 |
Opening time |
ms |
≤40 |
|||
22 |
Closing time |
ms |
20~45 |
|||
23 |
Closing bounce time |
ms |
≤2 |
|||
24 |
Asynchrony of three phase closing and opening |
mm |
≤2 |
|||
25 |
Three phase circuit resistance |
μΩ |
≤80 Band isolation≤120 |