Customizable High Voltage Outdoor Isolator Switch with Load Break Disconnector – Power Distribution Solutions

Product Details
Customization: Available
Type: 10kv/12kv/15kv
Structure: According to Customer Requirements
Still deciding? Get samples of $ !
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

OEM Services
The supplier provides OEM services for popular brands
Quality Assurance
The supplier provides quality assurance
Private Mold
The supplier has private mold
Product Certification
The supplier's products already have relevant certification qualifications, including:
CE
to see all verified strength labels (20)
  • Customizable High Voltage Outdoor Isolator Switch with Load Break Disconnector – Power Distribution Solutions
  • Customizable High Voltage Outdoor Isolator Switch with Load Break Disconnector – Power Distribution Solutions
  • Customizable High Voltage Outdoor Isolator Switch with Load Break Disconnector – Power Distribution Solutions
  • Customizable High Voltage Outdoor Isolator Switch with Load Break Disconnector – Power Distribution Solutions
  • Customizable High Voltage Outdoor Isolator Switch with Load Break Disconnector – Power Distribution Solutions
  • Customizable High Voltage Outdoor Isolator Switch with Load Break Disconnector – Power Distribution Solutions
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Certifications
Overview

Basic Info.

Model NO.
(H)GWBEB
Installation
Outdoor High-voltage
Operation
Manual/Electric/Pneumatic/Hydraulic
Grounding Mode
According to Customer Requirements
Movement Mode
According to Customer Requirements
Number of Poles
According to Customer Requirements
Grounding
According to Customer Requirements
Series
Two
Run
According to Customer Requirements
Switching Mode
According to Customer Requirements
Common Model
Gw9
Structure of Operating
According to Customer Requirements
Certification
ISO, RoHS, CE
Brand
Chbeb
Customizable
OEM/According to Customer Requirements
Transport Package
Standard Shipping Packing
Specification
45*55*38mm
Trademark
CHBEB
Origin
China
HS Code
853530900
Production Capacity
5000 PCS/Quarter

Packaging & Delivery

Package Size
45.00cm * 55.00cm * 38.00cm
Package Gross Weight
20.000kg

Product Description

Customizable High Voltage Outdoor Isolator Switch with Load Break Disconnector – Power Distribution Solutions
Product Description

Introducing the (H)GWBEB type outdoor high-voltage isolation switch, widely recognized as an isolation disconnect switch. This state-of-the-art device is masterfully crafted for deployment on 10(12, 15, 24)kV high voltage power transmission and distribution lines, providing the remarkable ability to open and close single-phase or three-phase circuits with the presence of voltage, sans load. Experience a new level of reliability and performance designed to meet the rigorous demands of modern electrical infrastructure.

Our switch is the epitome of simplicity, cost-efficiency, and user-friendliness, ideal for single-phase usage in three-phase line systems. With rated currents available in 200, 400, 600, 800, 1000, and 1250 amps, this switch is engineered to cater to diverse electrical needs. The switch is an assembly of a robust base, post insulators, conductive parts, and an intricate mechanical section. The intuitive gate knife structure ensures seamless circuit operations. Each phase features a dual-bladed conductive gate knife fortified with external compression springs, allowing for precise contact pressure adjustments. Operation is effortlessly executed using an insulated hook stick, complemented by a self-locking mechanism for enhanced safety and reliability.

Working Environment:

Ensure optimum performance with installation altitudes not exceeding 1000 meters.

Keep in mind the ambient temperature limits: a maximum of +40°C and a minimum of -30°C for flawless operation.

The switch is designed to withstand outdoor wind speeds of up to 35 meters/second.

This resilient switch can handle seismic intensities up to 8 degrees, provided the installation site remains free from frequent severe vibrations.

Choose installation sites wisely to avoid environments with gases, chemical deposits, salt mist, dust, dirt, or other explosive or corrosive mediums that could significantly impair the switch's insulation and conductivity.

Note:

SHOULD NORMAL CONDITIONS BE EXCEEDED, USERS ARE ENCOURAGED TO DISCUSS THEIR SPECIFIC NEEDS WITH OUR COMPANY FOR TAILORED SOLUTIONS.

 

Installation, Use and Adjustment

Pre-installation work

  1. Initiate pre-installation by meticulously removing dust and dirt from all parts, and gently wiping down the surface of the insulating porcelain bottle for peak performance.
  2. Thoroughly scrub the wiring surface of the ground screw to ensure optimal conductivity.
  3. A fine layer of industrial Vaseline should be applied to rotating parts and contact areas, safeguarding them against wear and corrosion.
  4. Inspect the contact surfaces diligently, adjusting the compression spring height as necessary to ensure contact pressure aligns with the specifications in Table II.
  5. Designed exclusively for hoisting applications, this switch is ideally used with transformers on the line to maximize efficiency.
  6. For optimal installation, the rated current of 200-400 ampere hours is typically accommodated with three mounting holes, as is the case for 600-1000A configurations.

Annual Routine Check-up: Ensure the longevity and reliability of the switch by regularly inspecting the following components each year:
Meticulously clean dirt from conductive parts, contact surfaces, and the insulating porcelain bottles to maintain pristine conditions.

Conduct thorough inspections for any signs of damage, with special attention to the insulating porcelain bottle for cracks or imperfections.

Consistently verify that the contact surface of the conductive part remains in optimal condition to ensure uninterrupted functionality.


Customizable High Voltage Outdoor Isolator Switch with Load Break Disconnector – Power Distribution Solutions

Detailed Photos

 

Customizable High Voltage Outdoor Isolator Switch with Load Break Disconnector – Power Distribution Solutions
Customizable High Voltage Outdoor Isolator Switch with Load Break Disconnector – Power Distribution Solutions
Customizable High Voltage Outdoor Isolator Switch with Load Break Disconnector – Power Distribution Solutions
Customizable High Voltage Outdoor Isolator Switch with Load Break Disconnector – Power Distribution Solutions


Customizable High Voltage Outdoor Isolator Switch with Load Break Disconnector – Power Distribution Solutions
Customizable High Voltage Outdoor Isolator Switch with Load Break Disconnector – Power Distribution Solutions

Customizable High Voltage Outdoor Isolator Switch with Load Break Disconnector – Power Distribution Solutions
Customizable High Voltage Outdoor Isolator Switch with Load Break Disconnector – Power Distribution Solutions
Customizable High Voltage Outdoor Isolator Switch with Load Break Disconnector – Power Distribution Solutions
Customizable High Voltage Outdoor Isolator Switch with Load Break Disconnector – Power Distribution Solutions
Customizable High Voltage Outdoor Isolator Switch with Load Break Disconnector – Power Distribution Solutions
Customizable High Voltage Outdoor Isolator Switch with Load Break Disconnector – Power Distribution Solutions
Customizable High Voltage Outdoor Isolator Switch with Load Break Disconnector – Power Distribution Solutions
Customizable High Voltage Outdoor Isolator Switch with Load Break Disconnector – Power Distribution Solutions
Customizable High Voltage Outdoor Isolator Switch with Load Break Disconnector – Power Distribution Solutions
Customizable High Voltage Outdoor Isolator Switch with Load Break Disconnector – Power Distribution Solutions
Customizable High Voltage Outdoor Isolator Switch with Load Break Disconnector – Power Distribution Solutions
Customizable High Voltage Outdoor Isolator Switch with Load Break Disconnector – Power Distribution Solutions

 

Product Parameters

The main technical parameters

Table I

Model

Rated voltage
kV

 

Rated current
A

kA

 

10 seconds thermal stable current
kA

peak

Valid values

 

(H)GW

 

10

12

15

200

5

9

5

400

21

15

10

600

35

25

14

630

35

25

14

800

35

25

14

1000

50

35

20

Contact force parameters

Table II

Model

Rated current(A)

contact pressure(kgf)

(H)GW

5

9

21

15

35

25

35

25

35

25

50

35