Introducing the ZW32-12 outdoor high voltage vacuum circuit breaker, a model of ingenuity in outdoor distribution switchgear, designed to excel at a rated voltage of 12kV with a dependable three-phase AC of 50Hz. This dynamic circuit breaker adeptly manages the interruption and connection of load current, overload current, and short circuit current within the power grid. It is equipped with cutting-edge overload and short circuit protective capabilities, effortlessly meeting control and measurement requirements while offering sophisticated remote control and monitoring features. Its extensive application spans substations, industrial environments, and mining enterprise distribution systems, providing unrivaled control and operation—perfect for environments requiring frequent operations.
Structural features:
Precision-crafted, the circuit breaker features a three-phase pillar dry design, epitomizing engineering excellence;
Meticulously engineered with a fully enclosed structure, it provides superior sealing, exceptional moisture resistance, and anti-condensation properties, making it an optimal choice for high-temperature and humid regions;
Employs cutting-edge vacuum arc extinguishing technology, ensuring remarkable insulation reliability;
Offers impeccable opening and closing performance, guaranteeing safety without the risk of combustion or explosion;
Compact, lightweight, maintenance-free, and promises an impressive and enduring lifespan;
Operational versatility-manual, electric, or remote control options cater to diverse needs;
The operating mechanism is expertly sealed at the base of the switch box, providing robust protection against outdoor environmental corrosion;
Exhibits a novel and simplistic design with a restless mechanism that assures reliable dynamic performance, a compact form, and an extraordinary service life of up to 10,000 cycles.
Main technical parameters:
No |
Name |
Unit |
Data |
|||
1 |
Rated voltage |
kV |
12 |
|||
2 |
Rated current |
A |
630 |
1250 |
||
3 |
Rated frequency |
Hz |
50 |
|||
4 |
Rated insulation level |
1min power frequency withstand voltage |
Dry test |
/ |
42/48(fracture) |
|
Wet test |
34 |
|||||
Secondary circuit to ground |
2 |
|||||
Lightning impulse withstand voltage (peak value) |
75/85(fracture) |
|||||
5 |
Rated short circuit making current (peak value) |
kA |
50 |
63 |
||
6 |
Rated short time withstand current |
kA |
20 |
25 |
||
7 |
Rated peak withstand current |
kA |
50 |
63 |
||
8 |
Breaking times of rated short circuit breaking current |
Times |
30 |
|||
9 |
Rated short circuit duration |
s |
4 |
|||
10 |
Rated operating voltage and rated voltage of auxiliary circuit |
V |
DC220,AC220 ,AC/DC220 |
|||
11 |
Rated operation sequence |
/ |
Off-0.3s-on-off-180s-on-off |
|||
12 |
Rated current of over current trip |
A |
5 |
|||
13 |
Mechanical life |
second |
10000 |
|||
14 |
Allowable wear accumulative thickness of moving and static contacts |
mm |
3 |
|||
15 |
Rated current of over current release |
A |
5 |
|||
16 |
Current ratio of current transformer |
/ |
200/5 400/5 600/5 |
|||
17 |
Contact opening distance |
mm |
9±1 |
|||
18 |
Contact overtravel |
mm |
2±0.5 |
|||
19 |
Average opening speed |
m/s |
1.2±0.3 |
|||
20 |
Average closing speed |
m/s |
0.6±0.2 |
|||
21 |
Opening time |
ms |
≤40 |
|||
22 |
Closing time |
ms |
20~45 |
|||
23 |
Closing bounce time |
ms |
≤2 |
|||
24 |
Asynchrony of three phase closing and opening |
mm |
≤2 |
|||
25 |
Three phase circuit resistance |
μΩ |
≤80 Band isolation≤120 |