Customization: | Available |
---|---|
Breaking Capacity: | 12kv/24kv/40.5kv |
Type: | Current Fuse |
Still deciding? Get samples of US$ 30/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
(H) RW(F) series outdoor high voltage AC drop fuse, referred to as the 'fuse', is purposefully crafted for outdoor overhead distribution systems. This marvel fits seamlessly with systems operating at a 50Hz frequency and offers versatility with rated voltages of 10kV, 12kV, 15kV, 35kV, and 40.5kV. Acting as a guardian for your circuits and equipment, it delivers unmatched protection against overloads and short circuits. In everyday use, the fuse stands firm, dynamically integrated into the power line, maintaining tension with a secure movable joint lock. Upon failure detection, the fuse swiftly responds to fault currents by blowing, releasing the joint, and decisively dropping the fuse tube to disconnect the circuit. This swift action ensures enhanced safety and line maintenance. Elevating the ordinary, our load type fuse incorporates an elastic contact and an arc extinguishing cover, empowering it to manage load currents within power systems with finesse.
Our fuses are crafted to conform to rigorous technical standards, including GB / T 15166.3 - 2008 for high voltage AC fuses, Part 3: injection fuses, as well as DL / T 640 - 1997 for outdoor AC high voltage drop-tested fuses and fuse links ordering technical conditions. This adherence underlines our commitment to quality and precision.
Working Environment:
Ambient temperature: Experience reliability from -40°C to +40°C;
Relative humidity: Dependable performance with a daily average not exceeding 95%, and a monthly threshold of 90%;
Designed for altitudes up to 3000m;
Built to withstand outdoor wind speeds up to 34 meters/second;
Setting: Install in environments devoid of fire, explosion risks, chemical corrosive gases and ensure a well-ventilated location.
Note: Should your conditions surpass these normal usage limits, a personalized negotiation with the company is recommended.
Technical parameters
Note: Our company is committed to delivering customized solutions tailored to user-specific requirements.
Model |
Voltage |
Current |
Rated maximum
breaking current |
1min power frequency dry withstand
voltage |
1min power frequency wet withstand
voltage |
Rated lightning impulse withstand
voltage |
Opening and closing
load current |
XS-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
XS-15/100(200) |
15 |
||||||
PD-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
PD-15/100(200) |
15 |
||||||
(H)RW3-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW3-12/100(200) |
12 |
||||||
(H)RW4-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW4-12/100(200) |
12 |
||||||
(H)RW7-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW7-12/100(200) |
12 |
||||||
(H)RW10-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW10-12/100(200) |
12 |
||||||
(H)RW10-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW10-12F/100(200) |
12 |
||||||
(H)RW11-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
! |
(H)RW11-12/100(200) |
12 |
||||||
(H)RW11-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW11-12F/100(200) |
12 |
||||||
(H)RW12-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
45 |
30 |
105 |
/ |
(H)RW12-12/100(200) |
12 |
||||||
(H)RW12-15/100(200) |
15 |
||||||
(H)PRWG1-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)PRWG1-12F/100(200) |
12 |
||||||
(H)RW33-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW33-15/100(200) |
15 |
||||||
(H)RW5-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)RW10-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)PRWG2-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |