(H) RW(F) Series – Outdoor High Voltage AC Drop Fuse: Engineered for excellence, this sophisticated fuse, hereinafter referred to as "fuse," is meticulously designed for outdoor overhead distribution systems with an impeccable rated frequency of 50Hz and robust rated voltage options of 10kV (12/15/35/40.5). Embrace the peace of mind offered by its role as a steadfast guardian of electrical circuits and equipment. In the unfortunate event of an overload or short circuit fault within a power system, this fuse stands as a vigilant protector. During regular operations, it effortlessly integrates in series within the power line, maintaining a state of tension with its locked movable joint. Upon detecting line failures, the fault current efficiently triggers the fuse, releasing the secure joint, swiftly dropping the fuse tube, and expertly severing the circuit, ensuring unparalleled safety and protection for line and equipment maintenance. Further elevating its utility, the load type fuse boasts an elastic contact and arc extinguishing cover, expertly crafted to manage the opening and closing of load currents within the power system.
Compliance and Standards: This fuse is meticulously crafted to comply with distinguished technical standards such as GB / T 15166.3 - 2008 for high voltage AC fuses - Part 3: injection fuses, alongside DL / T 640 - 1997 for outdoor AC high voltage drop tested fuses and fuse links ordering technical conditions, ensuring enduring reliability and performance.
Working Environment:
Ambient Temperature: Capable of withstanding the harshest climates, from a chilling -40°C to a balmy +40°C;
Relative Humidity: Designed to thrive in humidity, with a daily average not exceeding 95% and a monthly average not exceeding 90%;
Altitude: Functionality is reliable at altitudes not surpassing 3000 meters;
Wind Speed: Outdoor use is ensured withstanding wind speeds up to 34 meters per second;
Installation Site: Optimal performance in environments devoid of fire, explosion hazards, or chemical corrosive gases; a well-ventilated location is recommended.
Note: Should your usage conditions exceed these parameters, we welcome the opportunity to negotiate tailored solutions with you.
Technical Parameters
Note: Our company is equipped to cater to specific user requirements, offering flexibility in product supply to meet your precise needs.
Model |
Voltage |
Current |
Rated maximum
breaking current |
1min power frequency dry withstand
voltage |
1min power frequency wet withstand
voltage |
Rated lightning impulse withstand
voltage |
Opening and closing
load current |
XS-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
XS-15/100(200) |
15 |
||||||
PD-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
PD-15/100(200) |
15 |
||||||
(H)RW3-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW3-12/100(200) |
12 |
||||||
(H)RW4-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW4-12/100(200) |
12 |
||||||
(H)RW7-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW7-12/100(200) |
12 |
||||||
(H)RW10-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW10-12/100(200) |
12 |
||||||
(H)RW10-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW10-12F/100(200) |
12 |
||||||
(H)RW11-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
! |
(H)RW11-12/100(200) |
12 |
||||||
(H)RW11-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW11-12F/100(200) |
12 |
||||||
(H)RW12-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
45 |
30 |
105 |
/ |
(H)RW12-12/100(200) |
12 |
||||||
(H)RW12-15/100(200) |
15 |
||||||
(H)PRWG1-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)PRWG1-12F/100(200) |
12 |
||||||
(H)RW33-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW33-15/100(200) |
15 |
||||||
(H)RW5-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)RW10-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)PRWG2-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |