Customization: | Available |
---|---|
Breaking Capacity: | 12kv/24kv/40.5kv |
Type: | Current Fuse |
Still deciding? Get samples of US$ 30/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
(H) RW(F) series outdoor high voltage AC drop fuse, renowned as the "fuse", is meticulously designed for outdoor overhead distribution systems. This robust solution operates effortlessly with a rated frequency of 50Hz and a rated voltage spectrum of 10kV, 12kV, 15kV, 35kV, and 40.5kV. Crafted to be a vital guardian of your circuits or electrical equipment, it adeptly handles overloads and short circuits within power systems. Under normal conditions, the fuse integrates seamlessly in series with the power line, remaining taut and securely fastened. Upon encountering a line fault, the surge in fault current triggers the fuse to blow, unlocking the movable joint. This results in a swift drop of the fuse tube, effectively severing the circuit to ensure safety and maintenance of line and equipment. Uniquely, the load type fuse is enhanced with elastic contact and an arc extinguishing cover, empowering it to handle the opening and closing of load currents in power systems.
The fuse adheres to stringent technical standards, including GB/T 15166.3 - 2008 for high voltage AC fuses, Part 3: injection fuses, and DL/T 640 - 1997 for outdoor AC high voltage drop tested fuses and fuse links ordering technical conditions, ensuring unparalleled reliability and compliance.
Working Environment:
Ambient temperature: from a freezing -40°C up to a warm +40°C;
Relative humidity: daily average should not surpass 95%, while the monthly average must remain below 90%;
The altitude is limited to a maximum of 3000 meters;
Outdoor wind speed should not exceed a brisk 34 meters/second;
Installation site must be free from fire, explosion hazards, and chemical corrosive gases, while ensuring excellent ventilation.
Note: Should these normal usage conditions be exceeded, users are encouraged to coordinate with the company for tailored solutions.
Technical parameters
Note: We are committed to accommodating user-specific requirements for our products.
Model |
Voltage |
Current |
Rated maximum
breaking current |
1min power frequency dry withstand
voltage |
1min power frequency wet withstand
voltage |
Rated lightning impulse withstand
voltage |
Opening and closing
load current |
XS-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
XS-15/100(200) |
15 |
||||||
PD-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
PD-15/100(200) |
15 |
||||||
(H)RW3-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW3-12/100(200) |
12 |
||||||
(H)RW4-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW4-12/100(200) |
12 |
||||||
(H)RW7-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW7-12/100(200) |
12 |
||||||
(H)RW10-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW10-12/100(200) |
12 |
||||||
(H)RW10-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW10-12F/100(200) |
12 |
||||||
(H)RW11-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
! |
(H)RW11-12/100(200) |
12 |
||||||
(H)RW11-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW11-12F/100(200) |
12 |
||||||
(H)RW12-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
45 |
30 |
105 |
/ |
(H)RW12-12/100(200) |
12 |
||||||
(H)RW12-15/100(200) |
15 |
||||||
(H)PRWG1-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)PRWG1-12F/100(200) |
12 |
||||||
(H)RW33-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW33-15/100(200) |
15 |
||||||
(H)RW5-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)RW10-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)PRWG2-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |