Customization: | Available |
---|---|
Breaking Capacity: | 12kv/24kv/40.5kv |
Type: | Current Fuse |
Still deciding? Get samples of US$ 30/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
(H) RW(F) series outdoor high voltage AC drop fuse (hereinafter referred to as "fuse") is expertly crafted for integration into outdoor overhead distribution systems boasting a rated frequency of 50Hz and a range of rated voltages including 10kV(12/15/35/40.5). This fuse serves as an indispensable protection component for electrical circuits and equipment, diligently safeguarding against power system overloads or short circuit faults. During standard operations, it seamlessly connects in series within the power line, maintaining a taut and locked state at its movable joint. However, when a fault arises, the surge in fault current triggers the fuse to blow, swiftly releasing the movable joint. Consequently, the fuse tube descends rapidly, effectively severing the circuit and delivering essential safety protection for line and equipment maintenance. Enhanced with elastic contacts and an arc extinguishing cover, the load-type fuse elevates the functionality of standard types, adeptly opening and closing the load current within the power system.
The fuse is meticulously engineered to align with paramount technical standards, including GB / T 15166.3 - 2008 high voltage AC fuses - Part 3: injection fuses, as well as DL / T 640 - 1997 outdoor AC high voltage drop tested fuses and the precise technical ordering conditions for fuse links.
Working Environment:
Ambient temperature: -40°C to +40°C;
Relative humidity: The daily average does not surpass 95%, with the monthly average capped at 90%;
Ensured for altitudes not exceeding 3000 meters;
Designed for outdoor environments where wind speeds do not exceed 34 meters per second;
Installation site prerequisites: Areas free from fire hazards, explosion risks, and corrosive chemical gases, coupled with a well-ventilated setting.
Note: Should these standard usage conditions be exceeded, an open dialogue with our company is encouraged for tailored solutions.
Technical parameters
Note: Our company is poised to tailor product specifications to meet your individual requirements.
Model |
Voltage |
Current |
Rated maximum
breaking current |
1min power frequency dry withstand
voltage |
1min power frequency wet withstand
voltage |
Rated lightning impulse withstand
voltage |
Opening and closing
load current |
XS-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
XS-15/100(200) |
15 |
||||||
PD-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
PD-15/100(200) |
15 |
||||||
(H)RW3-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW3-12/100(200) |
12 |
||||||
(H)RW4-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW4-12/100(200) |
12 |
||||||
(H)RW7-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW7-12/100(200) |
12 |
||||||
(H)RW10-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW10-12/100(200) |
12 |
||||||
(H)RW10-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW10-12F/100(200) |
12 |
||||||
(H)RW11-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
! |
(H)RW11-12/100(200) |
12 |
||||||
(H)RW11-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW11-12F/100(200) |
12 |
||||||
(H)RW12-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
45 |
30 |
105 |
/ |
(H)RW12-12/100(200) |
12 |
||||||
(H)RW12-15/100(200) |
15 |
||||||
(H)PRWG1-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)PRWG1-12F/100(200) |
12 |
||||||
(H)RW33-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW33-15/100(200) |
15 |
||||||
(H)RW5-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)RW10-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)PRWG2-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |