(H) RW(F) series outdoor high voltage AC drop fuse (hereinafter referred to as "fuse") is a cutting-edge solution designed for outdoor overhead distribution systems with a rated frequency of 50Hz and a range of voltages including 10kV, 12kV, 15kV, 35kV, and 40.5kV. This innovative fuse acts as a vital protective element for circuits or electrical equipment, safeguarding against overloads or short circuits in power systems. Under normal conditions, the fuse remains securely tensioned and locked within the power line. However, in the event of a fault, the fault current triggers the fuse to blow, releasing the movable joint, allowing the fuse tube to swiftly drop and disconnect the circuit. This mechanism provides essential safety protection for the maintenance of lines and equipment. Enhanced with elastic contacts and an arc extinguishing cover, the load type fuse is adept at opening and closing load currents within power systems.
Our fuse is meticulously crafted to align with the highest technical standards, including GB / T 15166.3 - 2008 high voltage AC fuses - Part 3: injection fuses, and DL / T 640 - 1997 outdoor AC high voltage drop tested fuses and fuse links ordering technical conditions. This ensures dependable performance and unparalleled reliability.
Working Environment:
Ambient temperature: -40°C to +40°C; ensuring robust performance across extreme temperature ranges.
Relative humidity: the daily average is maintained at a maximum of 95%, while the monthly average does not surpass 90%; allowing for optimal functionality in humid conditions.
The altitude is to remain below 3000 meters; ensuring operational efficiency at various elevations.
Outdoor wind speed should not exceed 34 meters/second; supporting resilience against strong winds.
Installation site: should be free from fire hazards, explosion risks, chemical corrosive gases, and must be well-ventilated to ensure safe and effective operation.
Note: Should the operating conditions exceed the specified limits, users are encouraged to consult with the company for tailored solutions.
Technical parameters
Note: Our company is pleased to offer customized products that meet the specific requirements of our valued customers.
Model |
Voltage |
Current |
Rated maximum
breaking current |
1min power frequency dry withstand
voltage |
1min power frequency wet withstand
voltage |
Rated lightning impulse withstand
voltage |
Opening and closing
load current |
XS-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
XS-15/100(200) |
15 |
||||||
PD-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
PD-15/100(200) |
15 |
||||||
(H)RW3-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW3-12/100(200) |
12 |
||||||
(H)RW4-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW4-12/100(200) |
12 |
||||||
(H)RW7-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW7-12/100(200) |
12 |
||||||
(H)RW10-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW10-12/100(200) |
12 |
||||||
(H)RW10-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW10-12F/100(200) |
12 |
||||||
(H)RW11-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
! |
(H)RW11-12/100(200) |
12 |
||||||
(H)RW11-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW11-12F/100(200) |
12 |
||||||
(H)RW12-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
45 |
30 |
105 |
/ |
(H)RW12-12/100(200) |
12 |
||||||
(H)RW12-15/100(200) |
15 |
||||||
(H)PRWG1-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)PRWG1-12F/100(200) |
12 |
||||||
(H)RW33-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW33-15/100(200) |
15 |
||||||
(H)RW5-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)RW10-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)PRWG2-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |