Polymeric Lightning Protection with Unique User Requirement Customization

Product Details
Customization: Available
Type: Power Source Arrester
Structure: Zinc Oxide Arrester
Still deciding? Get samples of $ !
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

OEM Services
The supplier provides OEM services for popular brands
Quality Assurance
The supplier provides quality assurance
Private Mold
The supplier has private mold
Product Certification
The supplier's products already have relevant certification qualifications, including:
CE
to see all verified strength labels (20)
  • Polymeric Lightning Protection with Unique User Requirement Customization
  • Polymeric Lightning Protection with Unique User Requirement Customization
  • Polymeric Lightning Protection with Unique User Requirement Customization
  • Polymeric Lightning Protection with Unique User Requirement Customization
  • Polymeric Lightning Protection with Unique User Requirement Customization
  • Polymeric Lightning Protection with Unique User Requirement Customization
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Certifications
  • Company Profile
Overview

Basic Info.

Model NO.
YH series
Installation
According to Customer Requirements
Application
AC/DC System/Power Plants/Substation
Size
According to Customer Requirements
Operation Voltage
3 - 36kv
Shape
According to Customer Requirements
Material
ZnO
Certification
ROHS, ISO9001, CCC
Brand
Chbeb
Customizable
OEM/According to Customer Requirements
Voltage Customizable
30kv 33kv 36kv
Transport Package
Pallet
Trademark
CHBEB
Origin
China
HS Code
8535400000
Production Capacity
50000 Pieces/Quarter

Product Description

Product Description

Introducing the Zinc Oxide Arrester from Beierbian Group Co., Ltd - a groundbreaking innovation in lightning protection for 10kV power distribution systems. This revolutionary device is a marvel of modern engineering, featuring a cutting-edge zinc oxide valve column and exquisitely crafted upper and lower electrodes. The entire assembly is encased in premium silicone rubber, providing unmatched reliability and performance. Boasting exceptional features, this product sets a new benchmark in the industry:

  1. This pioneering design skillfully addresses and completely resolves the severe sealing challenges that have long plagued traditional arresters. By ingeniously merging the core and jacket into a seamless, compact unit, it eradicates any potential cavities that could lead to internal breathing issues, thereby expertly solving the technical concerns of moisture ingress within internal components.
  2. Equipped with a robust core capable of enduring significant internal overvoltage, this arrester showcases outstanding aging resistance. It guarantees prolonged, high-standard performance, providing unwavering protection that withstands the ravages of time and environmental pressures with remarkable resilience and dependability.

Utilizing a meticulously engineered valve plate combined with optimized core parameters, this device ensures superior protection. The core is expertly designed to counteract challenges such as arc grounding, PT resonance, and a spectrum of operational overvoltages. It operates with unparalleled reliability under line voltage conditions, while also enduring 2.5 to 3 times the power frequency overvoltage. Its voltage endurance far surpasses international standards by an extraordinary 1 to 3 orders of magnitude, delivering unmatched safety and operational longevity, and setting a new standard for high-performance protection solutions.
Polymeric Lightning Protection with Unique User Requirement Customization

Detailed Photos

Polymeric Lightning Protection with Unique User Requirement Customization

Polymeric Lightning Protection with Unique User Requirement Customization
Polymeric Lightning Protection with Unique User Requirement Customization
Polymeric Lightning Protection with Unique User Requirement Customization
Polymeric Lightning Protection with Unique User Requirement Customization
Polymeric Lightning Protection with Unique User Requirement Customization
Polymeric Lightning Protection with Unique User Requirement Customization

Product Parameters

Main Characteristics Of Jacket Materials And Product Usage Environment:

Item

Unit

Norm

Shore Hardness A

/

60

Tensile Strength

mpa

≥35

Breaking Elongation

%

≥250

Oxygen Index

/

45

Resistivity

Ω.m

≥1×1013

Breakdown Strength

MV/m

≥25

Tracking

kV

4.5

Durability

Not less than 20 years

Working Environment:

This surge arrester is exquisitely engineered to deliver unbeatable performance in any locale, seamlessly adapting to both indoor and outdoor environments. Its sophisticated design ensures that no matter where it's placed, it will operate with flawless precision and reliability, making it an ideal choice for diverse settings.

It triumphantly functions even at soaring altitudes, reaching an impressive 3000 meters with ease, demonstrating unmatched adaptability and steadfastness in high-altitude applications. This feature ensures reliable performance even in the most elevated environments.

Expertly crafted to operate flawlessly across a vast temperature spectrum of -40°C to +60°C, this product withstands the most frigid or balmy climates without compromise. Its robustness guarantees functionality in extreme weather conditions, offering peace of mind through unwavering reliability.

Intricately designed to align perfectly with power supply frequencies from a steady 48Hz to a dynamic 62Hz, ensuring optimal compatibility. This precise calibration maximizes efficiency and ensures seamless integration with various power systems.

Ensures the power frequency voltage between terminals remains perfectly optimized, paving the way for enduring, uninterrupted use. This meticulous voltage regulation is key to maintaining prolonged and consistent operation.

Built to endure seismic shocks up to 8 degrees in intensity, this product assures unparalleled stability and steadfastness. Its robust construction guarantees resilience against the most tumultuous seismic activities.

Crafted to resist vigorous outdoor winds up to 35 meters per second, offering unwavering reliability against the forces of nature. This ensures the product maintains its performance even under the harshest wind conditions.

Note:

For demands exceeding these standard operational limits, our expert team is poised to deliver custom solutions tailored specifically to your requirements. We pride ourselves on creating bespoke designs that cater to your unique needs, ensuring exceptional performance and satisfaction.

Main technical parameters

Model

Nominal Voltage

(rms)

Rated Voltage OArrester

(rms)

Continuous Operating Voltage

(rms)

DC 1mA reference voltage
kV not less than

The residual voltage under nominal discharge current
kV (Crest) not greater than

Steep wave impact residual voltage
kV (Crest) not greater than

2ms square wave flow capacity
A

Operation Place

YH5WS-3.8/17

3

3.8

2.0

7.5

17.0

19.6

100

 

Distribution Type

YH5WS-5/15

3

5

4.0

7.5

15.0

17.3

150

YH5WS-7.6/30

6

7.6

4.0

15.0

15.0

34.5

100

YH5WS-10/30

6

10

8.0

15.0

30.0

34.6

150

YH5WS-12.7/50

10

12.7

10

26.0

50.0

57.5

100

YH5WS-16.5/50

10

16.5

12.7

26.0

50.0

57.5

100

YH5WS-17/50

10

17

13.6

26.0

50.0

57.5

150

YH5WS-17/45

10

17

13.6

25.0

45.0

/

250

YH10WS-17/45

10

17

13.6

25.0

45.0

/

400

YH5WZ-5/13.5

3

5

4.0

7.2

13.5

15.5

200

Power Station Type

YH5WZ-7.6/27

6

7.6

4.0

14.4

27.0

31.0

150

YH5WZ-10/27

6

10

8.0

14.4

27.0

31.0

200

YH5WZ-42/134

35

42

23.4

73

134

154

150

YH5WZ-12.7/45

10

12.7

6.6

24.0

45.0

51.8

150

YH5WZ-16.5/45

10

16.5

13.2

24.0

45.0

51.8

150

YH5WZ-17/45

10

17

13.6

24.0

45.0

51.8

200

YH5WZ-51/134

35

51

40.8

73.0

134

154

400

YH10WZ-17/45

10

17

13.6

24.0

45.0

51.8

200

YH10WZ-51/134

35

51

40.8

73.0

134

154

400

YH5WR-5/13.5

3

5

4.0

7.2

13.5

/

400

Capacitive Type

YH5WR-7.6/27

6

7.6

4.0

13.8

27.0

/

400

YH5WR-10/27

6

10

8.0

14.4

27.0

/

400

YH5WR-12.7/45

10

12.7

6.6

23.0

45.0

/

400

YH5WR 17/45

10

17

13.6

24.0

45.0

/

400

YH5WX-51/134

35

51

40.8

73

134.0

154

400

Line type

YH1.5W-30/80

35

30

24

44

80.0

/

600

Neutral Type

Note: Featuring a robust Polymeric construction, the product's durability is significantly enhanced. This choice of materials strengthens the product, providing long-lasting and reliable service.

Model

Nominal Voltage

(rms)

Rated Voltage OArrester

(rms)

Continuous Operating Voltage

(rms)

DC 1mA Reference Voltage
kV Not Less Than

The Residual Voltage Under Nominal Discharge Current
kV (Crest)
Not Greater Than

Steep Wave Impact Residual Voltage
kV (Crest)
Not Greater Than

2ms Square Wave Flow Capacity
A

Operation Place

Y5WS-5/15

3

5

4.0

7.5

15.0

17.3

150

Distribution Type

Y5WS-7.6/30

6

7.6

4.0

15.0

15.0

34.5

100

Y5WS-10/30

6

10

8.0

15.0

30.0

34.6

150

Y5WS-12.7/50

10

12.7

10

26.0

50.0

57.5

100

Y5WS-16.5/50

10

16.5

12.7

26.0

50.0

57.5

100

Y5WS-17/50

10

17

13.6

26.0

50.0

57.5

150

Y5WZ-5/13.5

3

5

4.0

7.2

13.5

15.5

200

Power Station Type

Y5WZ-7.6/27

6

7.6

4.0

14.4

27.0

31.0

150

Y5WZ-10/27

6

10

8.0

14.4

27.0

31.0

200

Y5WZ-42/134

35

42

23.4

73

134

154

150

Y5WZ-12.7/45

10

12.7

6.6

24.0

45.0

51.8

150

Y5WZ-16.5/45

10

16.5

13.2

24.0

45.0

51.8

150

Y5WZ-17/45

10

17

13.6

24.0

45.0

51.8

200

Y5WZ-51/134

35

51

40.8

73.0

134

154

400

Y5WR-5/13.5

3

5

4.0

7.2

13.5

/

400

Capacitive Type

Y5WR-7.6/27

6

7.6

4.0

13.8

27.0

/

400

Y5WR-10/27

6

10

8.0

14.4

27.0

/

400

Y5WR-12.7/45

10

12.7

6.6

23.0

45.0

/

400

Y5WR-17/45

10

17

13.6

24.0

45.0

/

400

Y1.5W-0.28/1.3

0.22

0.28

0.24

0.6

1.3

/

75

Low Voltage

Y1.5W-0.5/2.6

0.38

0.5

0.24

1.2

2.6

/

75

Note:Porcelain

Model

 

Nominal Voltage
(Valid values)

 

Rated Voltage Of Arrester
(Valid values)

 

The Wave Front

Steepness Of The Shock Discharge

 

DC 1mA Reference Voltage

kV Not Less Than

 

1.2/50 Impulse Discharge Voltage

Not Greater Than

 

Wavefront Impulse

Discharge Voltage

 

kV Not Greater Than

The Residual Voltage Under Nominal Discharge

Current 8/20μs

 

kV Not Greater Than

 

2000μs Square

Wave Flow Capacity

 

4/10μs Impulse

Current Capacity

Y5CS-7.6/27

6

7.6

63

16

35

43.8

27

75

25

Y5CZ-7.6/24

6

7.6

63

16

30

37.5

24

150

40

Y5CS-12.7/45

10

12.7

106

26

50

62.5

45

75

25

Y5CS-12.7/41

10

12.7

106

26

45

56.5

41

200

40

Y5CZ-42/124

35

42.0

343

82

134

168

124

200

40

Note: Incorporates a Porcelain Series Gap specification, adding a touch of elegance and sophistication. This enhances both the aesthetic appeal and functional robustness of the product, making it a superior choice in its category.

Installation

(1) Prior to installation, examine the nameplate to ensure the arrester's rated voltage aligns with the system voltage at the designated installation point. This critical step guarantees compatibility and proper functionality.

(2) Offers flexible installation choices with options for suspension or vertical mounting. For vertical setups, ensure the arrester is not burdened as a load-bearing insulator. This flexibility in installation methods allows for versatile use in various environments.

(3) Fine-tune the lead wire length for optimal protection efficiency, minimizing stress and ensuring maximum equipment safety. This attention to detail in installation enhances the performance and longevity of the system.

Test

  • lTo bolster operational reliability, undertake preventive tests every 4-5 years, concentrating on measuring U1mA at both ends of the DC 1mA arrester. Regular testing secures long-term reliability and optimal performance.
  • lBefore setup, verify that the U1mA voltage is no less than 97% of the original factory value, diligently documenting this data for future reference. This verification step ensures consistent quality and effectiveness.
  • lDuring preventive maintenance, ensure the U1mA voltage consistently remains above 26kV. Maintaining this threshold is crucial for the system's dependable operation.
  • lNote: Minimize harmonic distortions in the DC power supply during tests to avert low U1mA readings due to faulty waveforms. Ensuring clean power supply integrity is vital for accurate testing results.
  • lThe newly unveiled 10kV synthetic insulated zinc oxide arrester for power distribution has proven its mettle in rigorous lab testing, continuously performing under outdoor line voltage conditions for 15 months. This testament to the jacket's superior quality, the arrester's reliable structure, and robust core stability, backed by annual performance data from 2,000 units, guarantees unrivaled protection, exceptionally low failure rates, and maintenance-free operation throughout its lifecycle. This remarkable durability and efficiency highlight its exceptional value and reliability in power distribution networks.Polymeric Lightning Protection with Unique User Requirement Customization
Certifications

Polymeric Lightning Protection with Unique User Requirement Customization

Company Profile

Polymeric Lightning Protection with Unique User Requirement Customization

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier