Outdoor High Voltage Isolation Switch with Reliable Load Break Function

Product Details
Customization: Available
Type: 10kv/12kv/15kv
Structure: According to Customer Requirements
Still deciding? Get samples of $ !
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

OEM Services
The supplier provides OEM services for popular brands
Quality Assurance
The supplier provides quality assurance
Private Mold
The supplier has private mold
Product Certification
The supplier's products already have relevant certification qualifications, including:
CE
to see all verified strength labels (20)
  • Outdoor High Voltage Isolation Switch with Reliable Load Break Function
  • Outdoor High Voltage Isolation Switch with Reliable Load Break Function
  • Outdoor High Voltage Isolation Switch with Reliable Load Break Function
  • Outdoor High Voltage Isolation Switch with Reliable Load Break Function
  • Outdoor High Voltage Isolation Switch with Reliable Load Break Function
  • Outdoor High Voltage Isolation Switch with Reliable Load Break Function
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Certifications
Overview

Basic Info.

Model NO.
(H)GWBEB
Installation
Outdoor High-voltage
Operation
Manual/Electric/Pneumatic/Hydraulic
Grounding Mode
According to Customer Requirements
Movement Mode
According to Customer Requirements
Number of Poles
According to Customer Requirements
Grounding
According to Customer Requirements
Series
Two
Run
According to Customer Requirements
Switching Mode
According to Customer Requirements
Common Model
Gw9
Structure of Operating
According to Customer Requirements
Certification
ISO, RoHS, CE
Brand
Chbeb
Customizable
OEM/According to Customer Requirements
Transport Package
Standard Shipping Packing
Specification
45*55*38mm
Trademark
CHBEB
Origin
China
HS Code
853530900
Production Capacity
5000 PCS/Quarter

Product Description

Outdoor High Voltage Isolation Switch with Reliable Load Break Function
Product Description

Introducing the (H)GWBEB type outdoor high-voltage isolation switch, an essential component also known as an isolation disconnect switch. This innovative switch is meticulously engineered for seamless operation on 10(12, 15, 24)kV high voltage power transmission and distribution lines, allowing you to safely open and close single-phase or three-phase circuits even when voltage is present, ensuring reliable performance without load.

Designed specifically for single-phase use within three-phase line systems, our switch is celebrated for its straightforward structure, economic value, and user-friendly operation. Choose from rated currents of 200, 400, 600, 800, 1000, and 1250 amps to match your specific needs. The switch's robust architecture includes a sturdy base, durable post insulators, high-quality conductive parts, and a precise mechanical section. Featuring an advanced gate knife structure for opening and closing circuits, each phase's gate knife consists of dual conductive blades enhanced by external compression springs on both sides. By adjusting the spring height, the optimal contact pressure for the switch's gate knife is diligently achieved, empowering the switch with unparalleled reliability. For ease of operation, it is equipped with an insulated hook stick for opening and closing actions, complemented by a self-locking device that ensures secure and stable performance.

Working Environment:

Perfectly suited for locations with an altitude not exceeding 1000 meters;

Designed to endure a wide range of temperatures: a maximum ambient temperature of up to +40°C and a minimum not dropping below -30°C;

Engineered to withstand outdoor wind speeds not exceeding 35 meters per second;

Crafted to endure seismic intensities not exceeding 8 degrees; ideal for sites where frequent severe vibrations are absent.

Ensure the installation site is free from gases, chemical deposits, salt mist, dust, dirt, or other explosive or corrosive mediums that could adversely affect the switch's insulation and conductivity, safeguarding its optimal performance.

Note:

SHOULD THE ABOVE NORMAL OPERATING CONDITIONS BE SURPASSED, USERS ARE ENCOURAGED TO ENGAGE IN DISCUSSIONS WITH OUR COMPANY FOR SUITABLE ARRANGEMENTS.

Installation, Use and Adjustment

Pre-installation work

  1. Ensure all components are free from dust and dirt, and meticulously clean the surface of the insulating porcelain bottle for optimal performance.
  2. Diligently scrub the wiring surface of the ground screw to ensure it is pristine.
  3. Generously apply a layer of industrial Vaseline to the rotating parts and contact areas to maintain smooth operation and prevent wear.
  4. Thoroughly inspect the contact surface and adeptly adjust the height of the compression spring to ensure that the contact pressure aligns with the specifications outlined in Table II.
  5. This switch is expertly designed exclusively for hoisting applications and is intended for use in conjunction with transformers on the line, ensuring seamless integration and superior functionality.
  6. The switch is available with a rated current of 200-400 ampere hours, and typically, three mounting holes are utilized for optimal stability. For currents ranging from 600-1000A, three mounting holes are consistently employed to ensure secure and reliable installation.

It is imperative to conduct a comprehensive annual check-up of the following components of the switch:
Meticulously remove any dirt from conductive parts, contact surfaces, and the surface of insulating porcelain bottles to maintain top-tier functionality.

Inspect all components for potential damage, with heightened attention to the integrity of the insulating porcelain bottle, checking for any signs of damage or cracks.

Examine the contact surface of the conductive part to ensure its pristine condition and optimal conductivity.


Outdoor High Voltage Isolation Switch with Reliable Load Break Function

Detailed Photos

Outdoor High Voltage Isolation Switch with Reliable Load Break Function
Outdoor High Voltage Isolation Switch with Reliable Load Break Function
Outdoor High Voltage Isolation Switch with Reliable Load Break Function
Outdoor High Voltage Isolation Switch with Reliable Load Break Function


Outdoor High Voltage Isolation Switch with Reliable Load Break Function
Outdoor High Voltage Isolation Switch with Reliable Load Break Function

Outdoor High Voltage Isolation Switch with Reliable Load Break Function
Outdoor High Voltage Isolation Switch with Reliable Load Break Function
Outdoor High Voltage Isolation Switch with Reliable Load Break Function
Outdoor High Voltage Isolation Switch with Reliable Load Break Function
Outdoor High Voltage Isolation Switch with Reliable Load Break Function
Outdoor High Voltage Isolation Switch with Reliable Load Break Function
Outdoor High Voltage Isolation Switch with Reliable Load Break Function
Outdoor High Voltage Isolation Switch with Reliable Load Break Function
Outdoor High Voltage Isolation Switch with Reliable Load Break Function
Outdoor High Voltage Isolation Switch with Reliable Load Break Function
Outdoor High Voltage Isolation Switch with Reliable Load Break Function
Outdoor High Voltage Isolation Switch with Reliable Load Break Function

Product Parameters

The main technical parameters

Table I

Model

Rated voltage
kV

 

Rated current
A

kA

 

10 seconds thermal stable current
kA

peak

Valid values

 

(H)GW

 

10

12

15

200

5

9

5

400

21

15

10

600

35

25

14

630

35

25

14

800

35

25

14

1000

50

35

20

Contact force parameters

Table II

Model

Rated current(A)

contact pressure(kgf)

(H)GW

5

9

21

15

35

25

35

25

35

25

50

35

Certifications

Outdoor High Voltage Isolation Switch with Reliable Load Break FunctionOutdoor High Voltage Isolation Switch with Reliable Load Break Function

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier