Polymeric Lightning Arrester Solutions for Voltage Surge Protection

Product Details
Customization: Available
Type: Power Source Arrester
Structure: Zinc Oxide Arrester
Still deciding? Get samples of $ !
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

OEM Services
The supplier provides OEM services for popular brands
Quality Assurance
The supplier provides quality assurance
Private Mold
The supplier has private mold
Product Certification
The supplier's products already have relevant certification qualifications, including:
CE
to see all verified strength labels (20)
  • Polymeric Lightning Arrester Solutions for Voltage Surge Protection
  • Polymeric Lightning Arrester Solutions for Voltage Surge Protection
  • Polymeric Lightning Arrester Solutions for Voltage Surge Protection
  • Polymeric Lightning Arrester Solutions for Voltage Surge Protection
  • Polymeric Lightning Arrester Solutions for Voltage Surge Protection
  • Polymeric Lightning Arrester Solutions for Voltage Surge Protection
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Certifications
  • Company Profile
Overview

Basic Info.

Model NO.
YH series
Installation
According to Customer Requirements
Application
AC/DC System/Power Plants/Substation
Size
According to Customer Requirements
Operation Voltage
3 - 36kv
Shape
According to Customer Requirements
Material
ZnO
Certification
ROHS, ISO9001, CCC
Brand
Chbeb
Customizable
OEM/According to Customer Requirements
Voltage Customizable
30kv 33kv 36kv
Transport Package
Pallet
Trademark
CHBEB
Origin
China
HS Code
8535400000
Production Capacity
50000 Pieces/Quarter

Product Description

Product Description

Introducing the state-of-the-art Zinc Oxide Arrester from Beierbian Group Co., Ltd—an extraordinary breakthrough in lightning protection technology, specifically designed for 10kV power distribution systems. This cutting-edge device is a pinnacle of innovation, expertly crafted with a zinc oxide valve column. It is enhanced by the precision placement of upper and lower electrodes, all flawlessly encapsulated in premium silicone rubber. This sophisticated construction presents unmatched features:

  1. Embrace the innovative design that masterfully tackles and resolves sealing challenges, which have historically plagued arrester systems. By elegantly integrating the core and jacket into a unified, streamlined entity, it meticulously eliminates potential cavities that could cause harmful internal breathing issues. Through this ingenious engineering, it successfully conquers the complex technical obstacles of preventing moisture ingress in the internal components, ensuring superior performance.
  2. Featuring a robust core with an impressive prowess to withstand internal overvoltage, this arrester is a testament to exceptional engineering. It displays remarkable aging resistance, guaranteeing consistent performance and steadfast protection year after year, assuring users of its long-lasting reliability and effectiveness.

With the integration of a specially engineered valve plate paired with optimized core parameters, this device ensures that the core can tackle challenges such as arc grounding, PT resonance, and a wide array of operational overvoltages. It operates with unparalleled reliability, confidently sustaining performance under normal line voltage, and enduring 2.5 to 3 times power frequency overvoltage. Its voltage withstand duration not only meets but exceeds international standards by 1 to 3 orders of magnitude, delivering unmatched safety and exceptional operational longevity.
Polymeric Lightning Arrester Solutions for Voltage Surge Protection

Detailed Photos

Polymeric Lightning Arrester Solutions for Voltage Surge Protection

Polymeric Lightning Arrester Solutions for Voltage Surge Protection
Polymeric Lightning Arrester Solutions for Voltage Surge Protection
Polymeric Lightning Arrester Solutions for Voltage Surge Protection
Polymeric Lightning Arrester Solutions for Voltage Surge Protection
Polymeric Lightning Arrester Solutions for Voltage Surge Protection
Polymeric Lightning Arrester Solutions for Voltage Surge Protection

Product Parameters

Main Characteristics Of Jacket Materials And Product Usage Environment:

Item

Unit

Norm

Shore Hardness A

/

60

Tensile Strength

mpa

≥35

Breaking Elongation

%

≥250

Oxygen Index

/

45

Resistivity

Ω.m

≥1×1013

Breakdown Strength

MV/m

≥25

Tracking

kV

4.5

Durability

Not less than 20 years

Working Environment:

Skillfully engineered to deliver impeccable performance in both indoor and outdoor environments;

Ensures seamless functionality at altitudes reaching an astonishing 3000 meters;

Designed to thrive across a vast spectrum of temperatures, enduring from a frigid -40C to a warm +60C;

Crafted to handle power supply frequencies that range from a stable 48Hz to a vibrant 62Hz with precision;

Ensures that the power frequency voltage applied between terminals remains within ideal parameters for consistent, long-term reliability.

Engineered to resist seismic activities with an intensity of up to 8 degrees, offering resilience during quakes.

Capable of withstanding strong outdoor wind speeds of up to 35 meters per second;

Note:

Facing conditions outside these operating standards? Our specialists are prepared to craft customized solutions for you.

Main Technical Parameters

Model

Nominal Voltage

(rms)

Rated Voltage OArrester

(rms)

Continuous Operating Voltage

(rms)

DC 1mA reference voltage
kV not less than

The residual voltage under nominal discharge current
kV (Crest) not greater than

Steep wave impact residual voltage
kV (Crest) not greater than

2ms square wave flow capacity
A

Operation Place

YH5WS-3.8/17

3

3.8

2.0

7.5

17.0

19.6

100

 

Distribution Type

YH5WS-5/15

3

5

4.0

7.5

15.0

17.3

150

YH5WS-7.6/30

6

7.6

4.0

15.0

15.0

34.5

100

YH5WS-10/30

6

10

8.0

15.0

30.0

34.6

150

YH5WS-12.7/50

10

12.7

10

26.0

50.0

57.5

100

YH5WS-16.5/50

10

16.5

12.7

26.0

50.0

57.5

100

YH5WS-17/50

10

17

13.6

26.0

50.0

57.5

150

YH5WS-17/45

10

17

13.6

25.0

45.0

/

250

YH10WS-17/45

10

17

13.6

25.0

45.0

/

400

YH5WZ-5/13.5

3

5

4.0

7.2

13.5

15.5

200

Power Station Type

YH5WZ-7.6/27

6

7.6

4.0

14.4

27.0

31.0

150

YH5WZ-10/27

6

10

8.0

14.4

27.0

31.0

200

YH5WZ-42/134

35

42

23.4

73

134

154

150

YH5WZ-12.7/45

10

12.7

6.6

24.0

45.0

51.8

150

YH5WZ-16.5/45

10

16.5

13.2

24.0

45.0

51.8

150

YH5WZ-17/45

10

17

13.6

24.0

45.0

51.8

200

YH5WZ-51/134

35

51

40.8

73.0

134

154

400

YH10WZ-17/45

10

17

13.6

24.0

45.0

51.8

200

YH10WZ-51/134

35

51

40.8

73.0

134

154

400

YH5WR-5/13.5

3

5

4.0

7.2

13.5

/

400

Capacitive Type

YH5WR-7.6/27

6

7.6

4.0

13.8

27.0

/

400

YH5WR-10/27

6

10

8.0

14.4

27.0

/

400

YH5WR-12.7/45

10

12.7

6.6

23.0

45.0

/

400

YH5WR 17/45

10

17

13.6

24.0

45.0

/

400

YH5WX-51/134

35

51

40.8

73

134.0

154

400

Line type

YH1.5W-30/80

35

30

24

44

80.0

/

600

Neutral Type

Note: Featuring a robust and enduring Polymeric construction.

Model

Nominal Voltage

(rms)

Rated Voltage OArrester

(rms)

Continuous Operating Voltage

(rms)

DC 1mA Reference Voltage
kV Not Less Than

The Residual Voltage Under Nominal Discharge Current
kV (Crest)
Not Greater Than

Steep Wave Impact Residual Voltage
kV (Crest)
Not Greater Than

2ms Square Wave Flow Capacity
A

Operation Place

Y5WS-5/15

3

5

4.0

7.5

15.0

17.3

150

Distribution Type

Y5WS-7.6/30

6

7.6

4.0

15.0

15.0

34.5

100

Y5WS-10/30

6

10

8.0

15.0

30.0

34.6

150

Y5WS-12.7/50

10

12.7

10

26.0

50.0

57.5

100

Y5WS-16.5/50

10

16.5

12.7

26.0

50.0

57.5

100

Y5WS-17/50

10

17

13.6

26.0

50.0

57.5

150

Y5WZ-5/13.5

3

5

4.0

7.2

13.5

15.5

200

Power Station Type

Y5WZ-7.6/27

6

7.6

4.0

14.4

27.0

31.0

150

Y5WZ-10/27

6

10

8.0

14.4

27.0

31.0

200

Y5WZ-42/134

35

42

23.4

73

134

154

150

Y5WZ-12.7/45

10

12.7

6.6

24.0

45.0

51.8

150

Y5WZ-16.5/45

10

16.5

13.2

24.0

45.0

51.8

150

Y5WZ-17/45

10

17

13.6

24.0

45.0

51.8

200

Y5WZ-51/134

35

51

40.8

73.0

134

154

400

Y5WR-5/13.5

3

5

4.0

7.2

13.5

/

400

Capacitive Type

Y5WR-7.6/27

6

7.6

4.0

13.8

27.0

/

400

Y5WR-10/27

6

10

8.0

14.4

27.0

/

400

Y5WR-12.7/45

10

12.7

6.6

23.0

45.0

/

400

Y5WR-17/45

10

17

13.6

24.0

45.0

/

400

Y1.5W-0.28/1.3

0.22

0.28

0.24

0.6

1.3

/

75

Low Voltage

Y1.5W-0.5/2.6

0.38

0.5

0.24

1.2

2.6

/

75

Note:Porcelain

Model

 

Nominal Voltage
(Valid values)

 

Rated Voltage Of Arrester
(Valid values)

 

The Wave Front

Steepness Of The Shock Discharge

 

DC 1mA Reference Voltage

kV Not Less Than

 

1.2/50 Impulse Discharge Voltage

Not Greater Than

 

Wavefront Impulse

Discharge Voltage

 

kV Not Greater Than

The Residual Voltage Under Nominal Discharge

Current 8/20μs

 

kV Not Greater Than

 

2000μs Square

Wave Flow Capacity

 

4/10μs Impulse

Current Capacity

Y5CS-7.6/27

6

7.6

63

16

35

43.8

27

75

25

Y5CZ-7.6/24

6

7.6

63

16

30

37.5

24

150

40

Y5CS-12.7/45

10

12.7

106

26

50

62.5

45

75

25

Y5CS-12.7/41

10

12.7

106

26

45

56.5

41

200

40

Y5CZ-42/124

35

42.0

343

82

134

168

124

200

40

Note: Utilizes Porcelain Series Gap specifications for enhanced performance.

Installation

(1) Prior to installation, check the nameplate to ensure the arrester's system rated voltage is in perfect harmony with the system voltage at the site of installation;

(2) Offers versatile installation options including suspension or vertical setups. For vertical installation, ensure the arrester is not used as a load-bearing insulator;

(3) Adjust lead wire length optimally to preserve protection effectiveness and reduce strain on the equipment.

Test

  • To boost operational dependability, conduct preventive tests every 4-5 years. These should focus on measuring U1mA at both terminals of the DC 1mA arrester for accuracy.
  • Before installation, verify that the U1mA voltage is at least 97% of the original factory value and accurately document this data.
  • During preventive maintenance, ensure the U1mA voltage remains above 26kV to sustain efficiency.
  • Note: Reduce harmonic components in the DC power supply during testing, as inadequate waveforms can result in reduced U1mA readings.
  • Our innovative 10kV synthetic insulated zinc oxide arrester for power distribution has successfully passed stringent laboratory evaluations, demonstrating steadfast performance under outdoor line voltage for 15 months. The findings highlight the jacket's exceptional quality, the arrester’s structural integrity, and the core's unwavering stability. Coupled with annual performance reports from 2,000 units, this product offers unparalleled protection, dramatically lower failure rates, and a maintenance-free lifespan.Polymeric Lightning Arrester Solutions for Voltage Surge Protection
Certifications

Polymeric Lightning Arrester Solutions for Voltage Surge Protection

Company Profile

Polymeric Lightning Arrester Solutions for Voltage Surge Protection

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier